Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 09, 2011 FBO #3667
MODIFICATION

Y -- Saltstone Disposal Unit - 6 (SDU-6)

Notice Date
12/7/2011
 
Notice Type
Modification/Amendment
 
NAICS
238110 — Poured Concrete Foundation and Structure Contractors
 
Contracting Office
Department of Energy, Savannah River Nuclear Solutions, LLC, Savannah River Nuclear Solutions, LLC, Savannah River Site, Bldg 730-2B, Aiken, South Carolina, 29808, United States
 
ZIP Code
29808
 
Solicitation Number
SRR00000435
 
Point of Contact
James Loftis, Phone: 803-952-6101, Keith Harp, Phone: 803-208-1469
 
E-Mail Address
james.loftis@srs.gov, keith.harp@srs.gov
(james.loftis@srs.gov, keith.harp@srs.gov)
 
Small Business Set-Aside
N/A
 
Description
Savannah River Remediation LLC (SRR), the liquid waste contractor at DOE's Savannah River Site (SRS) near Aiken, SC, will be procuring construction services to build a 32M gallon concrete tank to act as a low level waste disposal unit. This construction will be performed utilizing the Davis-Bacon Act. The mission of the Saltstone Facility at SRS is to process and dispose of low level radioactive salt solution from the liquid waste facilities. The Saltstone Facility immobilizes low level radioactive salt solution waste by mixing it with a dry material mixture of fly ash, slag, and cement to produce a flowable grout mixture. This grout is poured into large concrete disposal units, where it cures to become saltstone, a non-hazardous material, for permanent disposal. A disposal unit is expected to have the following attributes: - Type I concrete tank built to AWWA D110 - Class 3 concrete (Type V cement) - 375 ft diameter - 43 ft high - No wall or floor penetrations - ~50 roof penetrations - 100% leak tight - Leak detection system The scope includes: - Pouring the base slab - Reinforcing steel (rebar) - Erection of the tank walls including water stop installation between the wall and the floor and between wall segments - Roof support columns and roof - Wall pre-stressing - Shotcrete application over the pre-stress cables - Hydrotesting of the tank (test water will be supplied by SRR) - Repair of any leaks The scope excludes: - Design - Site preparation - Rough grading - Backfill The work will be performed to a quality program compliant with ASME NQA-1 The tank construction is not radiological work. NOTE: A Formal expression of Interest is anticipated to be issued in January 2012. When submitted, it should include a document, not to exceed 10 pages, which demonstrates the constructors past experience. A minimum of 3 customer references should be included for concrete vessels of at least 10 million gallons. One example of a construction to ASME NQA-1 is preferred, but not required.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/7162a778c9b04b64eb144751df0e6410)
 
Place of Performance
Address: Department of Energy (DOE) Savannah River Site (SRS), Aiken, South Carolina, 29808, United States
Zip Code: 29808
 
Record
SN02635055-W 20111209/111207234424-7162a778c9b04b64eb144751df0e6410 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.