Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 16, 2011 FBO #3674
SOURCES SOUGHT

31 -- Sources Sought for Dworshak and Little Goose Bearing Oil Coolers

Notice Date
12/14/2011
 
Notice Type
Sources Sought
 
NAICS
332710 — Machine Shops
 
Contracting Office
USACE District, Walla Walla, 201 N. Third Avenue, Walla Walla, WA 99362-1876
 
ZIP Code
99362-1876
 
Solicitation Number
W912EF12RSS05
 
Response Due
12/20/2011
 
Archive Date
2/18/2012
 
Point of Contact
Jacob M. Shaw, 509-527-7226
 
E-Mail Address
USACE District, Walla Walla
(jacob.m.shaw@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This announcement constitutes a Sources Sought (market survey). This is not a Request for Quote (RFQ) or a Request for Proposal (RFP). This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. The U.S. Army Corps of Engineers, Walla Walla District is seeking small business sources for a supply requirement entitled: "Dworshak and Little Goose Bearing Oil Coolers". This is scheduled to be issued as a Firm Fixed Price commercial supply contract. The purpose of this sources sought is to determine interest and capability of small businesses relative to the North American Industry Classification code (NAICS) 332710. The Small Business size standard for this NAICS code is 500 employees. To make an appropriate acquisition decision for this project, the Government may use responses to this sources sought. The type of solicitation issued and the manner of advertisement may depend on the responses to this sources sought. Large businesses may also respond to this announcement. SUBMISSION REQUIREMENTS FOR RESPONSES TO THIS SOURCES SOUGHT SYNOPSIS (1)Your intent to submit a proposal for this project when it is formally advertised (2)Name of firm with address, phone number, e-mail address and point of contact. (3)CAGE Code and DUNS number (4)The category of small business, such as small business, 8(a), HUBZONE, or SDVOSB if applicable. (5)Statement of Capability (SOC) stating your skills, experience, knowledge, and equipment required to perform the specified type of work. This should include documentation of past specialized experience and technical competence in fabricating similar product. Submit no more than three (3) past projects to document your firm's experience. The SOC should be no more than three pages in length. Firms responding to this sources sought synopsis that fail to provide ALL of the required information requested, will not be used to assist the Government in the acquisition decision, which is the intent of this sources sought synopsis. NOTE: IF YOU DO NOT INTEND TO SUBMIT A PROPOSAL FOR THIS PROJECT WHEN IT IS FORMALLY ADVERTISED, PLEASE DO NOT SUBMIT A RESPONSE TO THIS SOURCES SOUGHT SYNOPSIS. If inadequate responses are received, this solicitation may be issued on an unrestricted basis, for full and open competition. Where to send responses E-mail: jacob.m.shaw@usace.army.mil U.S. Army Corps of Engineers 201 North Third Avenue ATTN: Contracting/Jake Shaw Walla Walla, WA 99362 Phone: (509) 527-7226 Fax: (509) 527-7802 Response deadline December 20, 2011 Place of Performance (Delivery) U.S. Army Corps of Engineers, Walla Walla District Dworshak Dam, Ahsahka, Idaho and Little Goose Dam, Pomeroy, WA Description of requirement: 1.Furnish Two Thrust Bearing Oil Coolers for Dworshak Dam Units 1&2 Each hydropower unit at Dworshak powerhouse has two internal thrust bearing oil coolers in the oil tub. The requirement is to supply four spare (4) thrust bearing oil coolers at Dworshak Powerhouse. Two (2)of these coolers will be sized for use on Hydropower Units 1 and 2. Two (2) of these coolers will be sized for use on Hydropower Unit 3. The two new spare coolers for Dworshak Units 1 & 2 shall be sized to have a minimum cooling capacity of 134 KW per generating unit or 67 KW per cooler. A minimum fouling factor of.002hrs-ft^2-F/Btu shall be included in the design. The coolers shall have the same physical dimensions as existing to fit within the existing mounting supports in the thrust bearing housing. 2.Furnish Two Thrust Bearing Oil Coolers for Dworshak Dam Unit 3 Each hydropower unit at Dworshak powerhouse has two internal thrust bearing oil coolers in the oil tub. The requirement is to supply four spare (4) thrust bearing oil coolers at Dworshak Powerhouse. Two (2)of these coolers will be sized for use on Hydropower Units 1 and 2. Two (2) of these coolers will be sized for use on Hydropower Unit 3. The two new spare coolers for Dworshak Unit 3 shall be sized to have a minimum cooling capacity of 266 KW per generating unit or 133 KW per cooler. A minimum fouling factor of.002hrs-ft^2-F/Btu shall be included in the design. The coolers shall have the same physical dimensions as existing to fit within the existing mounting supports in the thrust bearing housing. 3.Furnish One Thrust Bearing Oil Cooler assembly (two halves) for Little Goose Dam Units 1-3 This requirement is to supply one spare (1) thrust bearing oil cooler assembly at Little Goose Powerhouse. There are two (2) semicircular oil coolers per unit/assembly. Each hydropower unit at Little Goose powerhouse has one thrust bearing oil cooler assembly. The cooler shall have the same cooling performance and physical dimensions as existing to fit within the existing mounting supports in the thrust bearing housing and be equipped with lifting fixtures to facilitate removal using the existing powerhouse overhead crane. All external steel surfaces will be blasted clean and painted with one coat of G.E. Clyptal #1202. Cooler assembly to be shipped in two semicircular halfs as shown on drawing. Along with studs, nuts, lock washers and gaskets to assemble unit complete. All welding will be performed by ASME code qualified welders. Other information: The solicitation will be posted to the Federal Business Opportunities web site (www.fbo.gov) when released. Quotes/Proposals will be due approximately 30 days after the actual solicitation issue date.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA68/W912EF12RSS05/listing.html)
 
Place of Performance
Address: USACE District, Walla Walla 201 N. Third Avenue, Walla Walla WA
Zip Code: 99362-1876
 
Record
SN02638735-W 20111216/111214233921-9112805e998ac61da40e26cf5f06c017 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.