H -- Inspect, Test, Maintenance, Calibration, and Single Line drawings of electrical power distribution system. - Attachment
- Notice Date
- 12/23/2011
- Notice Type
- Attachment
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- Department of Veterans Affairs;Rocky Mountain Network;VISN 19 Contracting;4100 E. Mississippi Avenue, Suite 1110;Glendale CO 80246
- ZIP Code
- 80246
- Solicitation Number
- VA25912Q0007
- Response Due
- 12/27/2011
- Archive Date
- 1/26/2012
- Point of Contact
- Glenn Breitling
- E-Mail Address
-
othill
- Small Business Set-Aside
- N/A
- Description
- Modification 002, 12/23/2011 to Solicitation VA-259-12-Q-0007, Inspect, Test, Maintenance, Calibration and Single Line Drawings of Electrical Power Distribution System The following clarifications are the result of questions from the facility walk through on December 20, 2011. 1.All low voltage breakers shall be tested in conformance to manufacturer ™s secondary injection testing method. 2.Primary testing method of circuit breakers will only be on the medium voltage breakers of the main distribution switch (Square D, 13.2 Kv). 3.Inspection, testing, maintenance and calibration shall occur within a two week period. This is dependent on the vendor ™s dispatch of personnel and approved schedule. The schedule as submitted by the vendor shall utilize weekends and those hours outside of the normal work days of the Medical Center. 4.Shutdown of mechanical systems, fire alarm system, steam generation, chilled water system and other equipment shall be coordinated by the vendor at the utility plant, Building 9. Additional coordination resulting in assistance from VA Maintenance & Operations staff, if needed, shall be through the Maintenance & Operation Foreman. 5.The spare circuit breaker, Main switch (Square D, 13.2Kv) shall be tested. 6.No ultrasound testing on 13.2Kv cabling. 7.Junction boxes will not be inspected. Pull boxes containing cable splices located in the ceiling of 1215-1 shall be inspected visually and by infrared. 8.Delete requirement for testing of North generator set (4D. page 10 of 60). 9.An updated file is available on the electrical panels. ZIP PDF updated Panel Schedules. Contact the contracting officer at glenn.breitling@va.gov to receive the file.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/SLCVAMC660/SLCVAMC660/VA25912Q0007/listing.html)
- Document(s)
- Attachment
- File Name: VA-259-12-Q-0007 VA-259-12-Q-0007_3.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=283779&FileName=VA-259-12-Q-0007-003.doc)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=283779&FileName=VA-259-12-Q-0007-003.doc
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA-259-12-Q-0007 VA-259-12-Q-0007_3.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=283779&FileName=VA-259-12-Q-0007-003.doc)
- Place of Performance
- Address: Grand Junction VA Medical Center;2121 North Avenue;Grand Junction, CO 81501
- Zip Code: 81501
- Zip Code: 81501
- Record
- SN02645385-W 20111225/111223234007-f697b2b92d79cd550924c21eb7f5d491 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |