SOURCES SOUGHT
34 -- OMAHA DISTRICT - Fabrication of Trash Racks at Fort Randall Dam and Gavins Point Dam in South Dakota
- Notice Date
- 4/19/2012
- Notice Type
- Sources Sought
- NAICS
- 332313
— Plate Work Manufacturing
- Contracting Office
- USACE District, Galveston, 2000 Fort Point Road, PO Box 1229, Galveston, TX 77553-1229
- ZIP Code
- 77553-1229
- Solicitation Number
- W912HY-12-S-0019
- Response Due
- 5/4/2012
- Archive Date
- 7/3/2012
- Point of Contact
- Sara Jackets, 402-995-2424
- E-Mail Address
-
USACE District, Galveston
(sara.l.jackets@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Sources Sought for Fabrication of Trash Racks W912HY-12-S-0019 Fort Randall Dam in Pickstown, Charles Mix Country, South Dakota and Gavins Point Dam in Yankton, Yankton County, South Dakota This is a request for SOURCES SOUGHT. This announcement seeks information from industry, which will be used for preliminary planning purposes. No proposals are being requested or accepted with this announcement. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS ANNOUNCEMENT. Respondents will not be notified of the results of the evaluation. The U.S. Army Corps of Engineers -, has been tasked to solicit for and award a project/procurement to include the fabrication of trash racks as per the original drawings with the modifications as shown on contract drawings, then hot dip galvanized. The proposed project will be a competitive, fixed price contract. The type of solicitation to be issued will depend upon the responses to this synopsis. No reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow up information requests. The purpose of this synopsis is to gain knowledge of interest, capabilities and qualifications of various members of industry, to include the Small Business Community: Small Business (SB) Section 8(a) Historically Underutilized Business Zones (HUB-Zone) Service-Disabled Veteran-Owned Small Business (SDVOSB) Small Disabled Small Business (SDB) Woman Owned Small Businesses (WOSB) Small business-led teams Small business joint ventures Other than Small (OTS) concerns The Government must ensure there is adequate competition among the potential pool of responsible contractors. PROJECT DESCRIPTION: Completion Time: 180 days North American Industry Classification System (NAICS) Code: 332313 Small Business Size Standard: 500 employees Full Description of the Project: The work includes the fabrication of trash racks as per the original drawings with the modifications as shown on contract drawings using Structural Carbon Steel. The work will include miscellaneous metal work required for the trash rack assembly but is not necessarily limited to continuous welding along the entire area of contact, except where tack welding is permitted. Drilling and punching and milling joints where required. The entire trash rack assembly shall then be hot dip galvanized after fabrication is complete. Assembled racks range in size with the largest being approximately 19 feet by 15 feet by 3 feet. Please see the pictures below. Work will be required to conform to the specifications and to the publications listed below to the extent that they are referenced. The publications are referred to within the text by the basic designation only. AMERICAN WELDING SOCIETY (AWS) AWS D1.1/D1.1M (2010) Structural Welding Code - Steel ASTM INTERNATIONAL (ASTM) ASTM A123/A123M (2009) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products ASTM A36/A36M (2008) Standard Specification for Carbon Structural Steel ASTM A780/A780M (2009) Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings Structural Carbon Steel ASTM A36/A36M and Galvanizing: ASTM A123/A123M WELDING Perform welding, welding inspection, and corrective welding, in accordance with AWS D1.1/D1.1M. Use continuous welds on all exposed connections. Grind visible welds smooth in the finished installation. Conform dimensional tolerances for welded construction, details of welds, and quality of welds with the applicable requirements of AWS D1.1/D1.1M and the contract drawings. Perform nondestructive testing by visual inspection and magnetic particle methods. The minimum extent of nondestructive testing shall be random 10 percent of welds or joints. GALVANIZE Entire trash rack assembly shall be hot dip galvanized after fabrication is complete. Repair damaged surfaces with galvanizing repair method and paint conforming to ASTM A780/A780M or by application of stick or thick paste material specifically designed for repair of galvanizing, as approved by Contracting Officer. SEE ATTACHED DRAWINGS Prior Government contract work is not required for submitting a response under this sources sought synopsis. Anticipated solicitation issuance date is on or about 1 June 2012, and the estimated proposal due date will be on or about 1 July 2012. The Pre-Solicitation Notice citing the solicitation number will be issued on Federal Business Opportunities www.fbo.gov and firms are invited to register electronically to receive a copy of the solicitation when it is issued. Firm's response to this SOURCES SOUGHT shall be limited to thirty (30) pages and shall include the following information: 1. Firm's name, address, point of contact, phone number, e-mail address, CAGE code, and DUNS number. Please include existing Joint Venture information if applicable. 2. Firm's small business category and business size in relation to the NAICS Code 332313. 3. Firm's geographic span. 4. Firm's Bonding Capability (construction bonding level per contract and aggregate construction bonding level, both expressed in dollars) via letter from bonding company. 5. Firm's project and past performance information addressing the capability to perform a contract of this magnitude and complexity completed within the past six (6) years. At least three (3), but no more than five (5) project examples must clearly demonstrate the firm's familiarity and experience on projects with similar scope as described above. For each project, include the following information: a. Size, duration, and complexity of job; b. Information on your role as either a prime contractor or subcontractor; c. Point of contact (POC) at the agency or prime contractor's organization to verify contract information, including name, address, e-mail address, telephone number, and information on the specific tasks you performed on the project; d. Overall past performance rating. 6. Please provide a brief description of your experience either managing a team or acting as a member of a team of businesses working on large, complex projects. Provide a POC (name, address, e-mail address, and telephone number) that can verify this experience. Firms responding to this sources sought announcement, who fail to provide ALL of the required information requested, will not be used to assist the Government in the acquisition decision, which is the intent of this sources sought announcement. Interested Firm's shall respond to this Sources Sought no later than 14:00 Central Daylight Time (CDT) 4 May 2012. All interested firms must be registered in CCR to be eligible for award of Government contracts. For technical questions please contact, Mr. David LaGrone at (402) 995-2453 or e-mail David.L.LaGrone@usace.army.mil. Email is the preferred method when receiving response to this synopsis, but you may also mail or fax your response to Sara L. Jackets at: EMAIL: sara.l.jackets@usace.army.mil MAIL: U.S. Army Corps of Engineers Contracting - Sara Jackets 1616 Capitol Avenue Omaha, NE 68102-4901 FAX: (402) 766-6306
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA64/W912HY-12-S-0019/listing.html)
- Place of Performance
- Address: USACE Omaha District Fort Randall Dam and Gavins Point Dam Pickstown/Yankton SD
- Zip Code: 57367
- Zip Code: 57367
- Record
- SN02726284-W 20120421/120419235725-6075511fe5b376f64a58790adc646017 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |