SOLICITATION NOTICE
99 -- Market Survey- Roof Replacement Project at the Pago Pago VORTAC facility at the Pago Pago International Airport
- Notice Date
- 6/19/2012
- Notice Type
- Presolicitation
- Contracting Office
- FEDERAL AVIATION ADMINISTRATION, AAQ-530 AWP - Western Pacific
- ZIP Code
- 00000
- Solicitation Number
- DTFANM-12-R-00119
- Response Due
- 6/22/2012
- Archive Date
- 7/7/2012
- Point of Contact
- Lelanie Rivera, 425-227-1003
- E-Mail Address
-
lelanie.rivera@faa.gov
(lelanie.rivera@faa.gov)
- Small Business Set-Aside
- N/A
- Description
- The Federal Aviation Administration, Northwest Mountain Region, Western Service Area, is conducting a Market Survey/Request for Information to improve the Government's understanding of the current marketplace and to identify capable sources. Responses to this market survey will be used to determine if there is adequate competition to set the requirement aside for Socially and Economically Disadvantaged Businesses (SEDB/8(a)), Small Businesses, Service Disabled Veteran Owned Small Businesses (SDVOSB), etc. This survey is being conducted in accordance with FAA Acquisition Management System (AMS) Section 3.2.1.2.1. This survey will support market research obtained from multiple sources and will be utilized for planning purposes only. All interested vendors are advised that the FAA will not pay for any information or any administrative costs incurred that are associated with any response received from industry in response to this Market Survey/Request for Information. Therefore, any costs associated with vendor's market Survey/Request for Information submissions will be solely at the interested vendor's expense. Summary of Work: This project scope describes the project requirements for refurbishing the Pago Pago VORTAC facility located at Pago Pago Intl Airport. The VORTAC building footprint is 37' X 37' on a concrete foundation with 10' concrete walls and a steel roof frame supporting a 53' diameter circular roof. The contractor shall furnish all management, labor, tools, equipment, transportation, and materials for the project. All work shall be accomplished by qualified experienced licensed contractors. See Section 1.04 for detailed specifications. Contractor shall submit a cost for each Contract Line Item Number (CLIN): CLIN 001: ROOF PREPARATION Remove TACAN, collar and teepee. Wrap and store TACAN. Dispose of teepee and collar. Weatherproof all equipment and electronics inside the equipment room. CLIN 002: DEMOLITION Remove existing roofing and insulation. Remove copper roofing. Remove existing wood decking and nailers connected to the steel joists. Remove fascia and soffits. Remove drop ceiling and light fixtures. Remove metal AC rack. CLIN 003: ROOF REPLACEMENT Refurbish corroded steel fascia clips. Install trimmed wood nailers to the steel joists. Install 2X6 T&G wood decking. Install antenna mount brackets. Install roof underlayment. Install 16 oz. copper sheeting. Install roofing insulation and fully adhered membrane roofing and associated flashing. Install 2X12 fascia and soffit. Install an attached gypsum wallboard ceiling. Install ladder supports. CLIN 004: TEEPEE INSTALLATION Assemble and paint GFM teepee. Assemble GFM collar and vent covers. Install teepee, collar and stored TACAN. CLIN 005: EXTERIOR WALL COATING Remove and dispose loose lead based paint (LBP) flakes. Concrete patch damaged wall areas. Paint the exterior walls and soffit with an epoxy undercoat and a polyurethane top coat. Paint is GFM. CLIN 006: ELECTRICAL Install interior suspended light fixtures and mounted exterior light fixtures. CLIN 007: BUILDING IMPROVEMENTS Paint two (2) existing exterior doors. Install a 3'X7' steel door and associated hardware to the transformer shed. Remove and replace a wall louver. Install a 12" concrete riser to a communication handhold. CLIN 008: TACAN MAST INSTALLATION Remove existing utility pole and messenger cable. Construct concrete foundation. Install buried duct from the VORTAC building to the foundation. Assemble and install GFM TACAN mast. CLIN 009: GROUNDING Install buried earth electrode system (EES) loop around the VORTAC building. Install ground rods and connect to the EES by exothermic welding. Connect the EES to the copper roof, building steel, transformer and main service entrance by exothermic welding. Install ground plates and connect to the EES. Response to this Market Survey: Any information provided in response to this market survey will be used for informational purposes only and will not be released. Any proprietary information submitted will be protected if appropriately marked. Vendor participation in any informational session is not a promise of future business with the FAA. Response submittals must include the following information (Submittals by email): A) Name of company B) Address C) Phone and Fax number D) Point of contact E) Email address F) Business size status: 8(a), Small Business, SDVOSB, VSB, etc. G) Verification of registration in the Central Contractor's Registration (CCR) H) List of 3 past experience of projects in similar size and scope within the last 3 years to the proposed requirement outlined in the Scope of Work. **** Excessively elaborate presentations are neither required nor desired. Please submit responses to the market survey by close of business (2 pm, PST) by June 22, 2012. The FAA prefers that all response submittals, including attachments, be submitted electronically to the following email at: Lelanie.Rivera@faa.gov
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOT/FAA/WPR/DTFANM-12-R-00119/listing.html)
- Record
- SN02780236-W 20120621/120619235839-bd83975b3591b47fd236857f401c45a4 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |