Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 11, 2012 FBO #3882
MODIFICATION

20 -- Relay's and Switch Controls

Notice Date
7/9/2012
 
Notice Type
Modification/Amendment
 
NAICS
335314 — Relay and Industrial Control Manufacturing
 
Contracting Office
Department of the Navy, Military Sealift Command, MSC East - Norfork, Virginia, Building SP-64, 471 East C Street, Norfolk, Virginia, 23511, United States
 
ZIP Code
23511
 
Solicitation Number
N40442-12-T-7515
 
Archive Date
7/31/2012
 
Point of Contact
Roy J. Williams, Phone: 757-443-5960
 
E-Mail Address
roy.williams@navy.mil
(roy.williams@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
THIS SOLICITATION HAS BEEN MODIFIED TO ALLOW FOR FULL AND OPEN COMPETITION AND TO EXTEND THE RESPONSE DATE TO 16 JULY 2012. THIS CHANGE REFLECTS REVISION "A" TO THE SOLICITATION. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format prescribed in Subpart 12.6 of the Federal Acquisition Regulation (FAR), as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is N40442-12-T-7515, and it is being issued as a request for quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-58, effective 18 May 2012. NAICS code 335314 applies. Military Sealift Fleet Support Command (MSFSC), Norfolk, VA intends to award a firm fixed price purchase order for USNS Humphreys for the following services: The requested period of performance for the below service is 12 August - 22 September 2012. 1.0 ABSTRACT 1.1 Perform complete annual inspection, maintenance and repairs on designated air circuit breakers and supervision of switch board cleaning. 2.0 REFERENCE/ENCLOSURES 2.1 References: 2.1.1 NAVSEA Tech Manual T9550-AP-MMC-010, Switchboards, Ship's Service and Emergency. (available onboard vessel) 2.1.2 NAVSEA Tech Manual T9550-AD-MMC-010, Control Center and Individual Controllers. (available onboard vessel) 2.2 Enclosures: None. 3.0 ITEM LOCATION/DESCRIPTION 3.1 Description/Manufacturer's Data: 3.1.1 120 V Lighting Switchboard Bus "A" 3.1.2 Spare for Lighting Mfr. FPE Mfr. FPE Type: 30HL-3 Type: 30HL-3 Frame 800 Amp Frame 800 Amp Serial No. BH28838-85 Serial No. BH28840-84 3.1.3 120 V Lighting Switchboard Bus "B" 3.1.4 Forward Lighting Load Center 1SA Mfr. FPE Mfr. FPE Type: 30HL-3 Type: 30HL-3 Frame 600 Amp Frame 800 Amp Serial No. CCBS167-01 Serial No. BH28841-85 3.1.5 Group Control Center "F" Vital 3.1.6 Group Control Center "C" Vital Mfr. FPE Mfr. FPE Type: 30HL-3 Type: 50HL-3 Frame 800 Amp Frame 2000 Amp Serial No. BH28839-85 Serial No. BH28834-85 3.1.7 Emerg. Swbd. Bus Tie (1SA) 3.1.8 Group Control Center "A" Vital Mfr. FPE Mfr. FPE Type: 50HL-3 Type: 50HL-3 Frame 1600 Amp Frame 2000 Amp Serial No. BH28837-85 Serial No. BH28833-85 3.1.9 450 V Bus 1SA GCC 3.1.10 Emerg Swbd. Bus Tie (1SB) Mfr. FPE Mfr. FPE Type: 50HL-3 Type: 50HL-3 Frame 1600 Amp Frame 1600 Amp Serial No. BH28835-85 Serial No. BH28836-85 3.1.11 SSDG #4 Breaker 3.1.12 SSDG#3 Breaker Mfr. FPE Mfr. FPE Type: 100H-3 Type: 100H-3 Frame 4000 Amp Frame 4000 Amp Serial No. BH28832-85 Serial No. CCBS196-01 3.1.13 PTO #1 Breaker 3.1.14 PTO #2 Breaker Mfr. FPE Mfr. FPE Type: 100H-3 Type: 100H-3 Frame 4000 Amp Frame 4000 Amp Serial No. BH28831-85 Serial No. BH28828-85 3.1.15 1SB Bus Tie (non-auto) 3.1.16 Emergency Generator Mfr. FPE Mfr. FPE Type: 50H-3 Type: 50H-3 Frame 1600 Amp Frame 1600 Amp Serial No. BH28885-85 Serial No. CCBS162-05 3.1.17 120 V Emergency Bus 3.1.18 Fwd. Emergency Light Load Center Mfr. FPE Mfr. FPE Type: 30HL-3 Type: 30HL-3 Frame 600 Amp Frame 600 Amp Serial No. BH28887-85 Serial No. BH28889-85 3.1.19 Fwd. Emergency Load Center 3.1.20 1SA Bus Tie Mfr. FPE Mfr. FPE Type: 30HL-3 Type: 100H-3 Frame 600 Amp Frame 4000 Amp Serial No. BH28888-85 Serial No. BH28827-85 3.1.21 1SB Bus Tie 3.1.22 1SA Bus Tie (non-auto) Mfr. FPE Mfr. FPE Type: 100H-3 Type: 50H-3 Frame 4000 Amp Frame 1600 Amp Serial No. BH28829-85 Serial No. BH28886-85 3.1.23 Spare for Emergency Bus Tie 3.1.24 SSDG/PTO Spare Mfr. FPE Mfr. FPE Type: 50HL-3 Type: 100H-3 Frame 1600 Amp Frame 4000 Amp Serial No. BH38541-86 Serial No. BH28470-84 3.1.25 Spare for Group Control Center Vital 3.1.26 SSDG/PTO Spare Mfr. FPE Mfr. FPE Type: 50HL-3 Type: 100H-3 Frame 2000 Amp Frame 4000 Amp Serial No. BH31540-86 Serial No. BH28830-85 3.1.27 Emergency Generator Spare 3.1.28 Spare Mfr. FPE Mfr. FPE Type: 50HL-3 Type: 100H-3 Frame 1600 Amp Frame 4000 Amp Serial No. Bh28884-85 Serial No. 3.1.29 Spare Mfr. FPE Type: 100H-3 Frame 4000 Amp Serial No. 3.2 Quantity: 3.2.1 Twenty-nine (29) air circuit breakers to be dealt with. 4.0 GOVERNMENT FURNISHED EQUIPMENT/MATERIAL/SERVICES 4.1 Government Furnished Services (GFS): Government will provide a field service engineer for breaker maintenance, technical assistance and advice to the MSCREP. 5.0 NOTES 5.1 This item shall be worked in conjunction with item no. 305, Switchboard and Motor Controller Cleaning, found elsewhere in this work package. 5.2 Location 6.0 QUALITY ASSURANCE REQUIREMENTS 6.1 All work shall be performed to the satisfaction of the Port Engineer and the Chief Engineer. 7.0 STATEMENT OF WORK REQUIRED 7.1 All work performed on the circuit breakers listed in paragraph 3.0 shall be by a qualified service technician, experienced in the inspection, repair, and overhaul of Federal Pacific Circuit Breakers, in accordance with reference 2.1.1 & 2.1.2, and to manufacturer specifications. Provide all special tools, testing instruments, and OEM repair parts required by this work item. 7.1.1 In conjunction with ship's force, isolate and tag out the individual circuit breakers described in paragraph 3.0 prior to commencement of repairs. 7.1.1.1 Service technician provide supervision of switch board cleaning as per item 305, found in elsewhere in this work package. 7.1.2 Rack out and remove the individual circuit breakers for inspection and repair. Upon completion of repairs and inspections, reinstall and rack in the individual circuit breakers. 7.1.3 Remove all arc chutes, barriers, boxes and faceplates. 7.1.4 Thoroughly disassemble, clean and inspect breakers including all closing linkages. 7.1.5 Remove oxidation from main contacts and moving contacts. 7.1.6 Lubricate and exercise breakers. 7.1.7 Inspect and make all necessary adjustments according to manufacturer's specifications. 7.1.7.1 Conduct micro ohms test on breakers according to manufacturer's specifications with 100 AMP test set. 7.1.7.2 Check differential according to manufacturer's specifications using manufacturer's recommended tool. 7.1.7.3 Check deflections in accordance with manufacturer's specifications using manufacturer's recommended tool. 7.1.7.4 Check contact pressure and make all necessary adjustments according to manufacturer's specifications with manufacturer's recommended tool. 7.1.7.5 Test all electronic overload protection relays according to manufacturer's specifications using manufacturer's recommended test set. 7.1.8 Test all electrical operated breakers electrically on bench and in the switchboard. 7.1.9 Check all anti single-phase protection for damages and electrical test to make sure that the breaker will trip. 7.1.10 Check all contacts for damages, pitting or wear. 7.1.11 Remove, clean, and inspect to manufacturer specifications clusters for all breakers. 7.1.12 Check all under voltage assemblies. 7.1.13 Submit two (2) copies of a written report of the results of the tests and inspections, along with any recommended repairs or repair parts, to the Port Engineer. 7.1.13.1 The cost of additional repairs or repair parts, if authorized, shall be covered by a change order to this work item. 7.1.14 Perform the following known repairs to the circuit breakers: 7.1.14.1 Replace the old style latch check switches with the new style on the following breakers: 7.1.15 Upon completion of repairs and testing, reassemble and reinstall the breakers in their original locations. 7.1.15.1 Label individual breakers with service date, company name, phone number and number of cycles. 7.1.16 Provide two (2) copies of a written report of results of inspections, repairs, and testing of the individual circuit breakers to the Port Engineer. 7.2 Conduct an operational test of the individual circuit breakers to the satisfaction of the Chief Engineer and the Port Engineer. 7.3 Mechanically clean, prepare, prime and paint all new and disturbed areas to match surrounding surfaces. 7.4 All dirt and debris shall be removed from the ship on a daily basis and work areas left clean and in good order. 7.5 Preparation of Drawings: None. 7.6 Manufacturer's Representative: 7.6.1 The Government shall provide a qualified service technician, experienced in the inspection, repair, and overhaul of Federal Pacific Circuit Breakers, throughout the performance of this work item. Service technician shall provide all special tools, testing instruments, and OEM repair parts required by this work item. 8.0 GENERAL REQUIREMENTS 8.1 None additional. The following FAR and DFAR provisions and clauses apply to this solicitation and are incorporated by reference: 52.204-7 Central Contractor Registration; 52.212-1 Instructions to Offerors-Commercial Items; 52.212-3 Alt I Offeror Representations and Certifications - Commercial Items (Offerors are advised to include a completed copy of this provision with their quote or a statement stating that it is available via the ORCA website, https://www.acquisition.gov.) 52.212-4 Contract Terms and Conditions-Commercial Items; 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items 52.204-10 Reporting Executive Compensation and First-Tier Subcontract Awards (over 25k) 52.209-6 Protecting the Government' Interest When Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment (over 30K) 52.219-28 Post-Award Small Business Program Representation. 52.222-3 Convict Labor, 52.222-19 Child Labor - Cooperation with Authorities and Remedies, 52.222-21 Prohibition of Segregated Facilities, 52.222-26 Equal Opportunity, 52.222-35 Equal Opportunity for Disabled Veterans (over 100K) 52.222-36 Affirmative Action for Workers with Disabilities, (Over 15K) 52.222-37 Employment Reports on Special Disabled Veterans (When 52.222-35 Applies) 52.223-18 Contractor Policy to Ban Text Messaging While Driving 52.225-13 Restrictions on Certain Foreign Purchases, and 52.232-33 Payment by Electronic Funds Transfer --Central Contractor Registration 52.222-41 Service Contract Act 52.222-42 Statement of Equivalent Rates for Federal Hires (only used when 52.222-41 applies) 52.215-5 Facsimile Proposals: (757) 443-5982 52.222-50 Combating Trafficking in Persons 52.232-18 Availability of Funds (only used with an unapproved budget, not standard) 252.203-7005 Representation Relating to Compensation of Former DoD Officials 252.204-7004 Required Central Contractor Registration. Alternate A; 252.209-7999 Representation by Corporations Regarding an Unpaid Delinquent Tax Liability or a Felony Conviction under any Federal Law 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Application to Defense Acquisition of Commercial Items 252.203-7000 Requirements Relating to Compensation of Former DoD Officials 252.225-7001 Buy American Act--Balance of Payments Program; 252.232-7003 Electronic Submission of Payment Requests; and 252.247-7023 Transportation of Supplies by Sea Alternate III. 252.225-7000 Buy American Act--Balance of Payments Program Certificate, 52.252-2 Clauses Incorporated by Reference This contract incorporates one or more clauses by reference with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause my be accessed electronically at this/these address(es): http://www.arnet.gov/far Responsible sources shall provide the following: 1. Price quote which identifies the requested item(s), unit price, and extended price 2. Total price 3. Prompt Payment Terms 4. Remittance address, Tax Identification Number, DUNS number and Cage Code 5. Responses to this solicitation are due 30 September 2012 at 0800 local time, Norfolk, VA. LATE QUOTES MAY NOT BE CONSIDERED FOR EVALUATION. Quotes may be emailed to Roy.Williams@navy.mil or faxed via 757-443-5982 Attn: Roy Williams. Please reference the solicitation number on your quote. MSFSC INVOICE INSTRUCTIONS FOR SHIPPING CHARGES At the time of invoice, a shipping receipt must be provided to substantiate shipping or freight charges greater than $25.00. MSC WIDE AREA WORKFLOW (WAWF) INSTRUCTIONS (APR 2012) To implement DFARS 252.232-7003, Electronic Submission of Payment Requests and Receiving Reports (MAR 2008), Military Sealift Command (MSC) utilizes Wide Area WorkFlow (WAWF) to electronically process vendor requests for payment. This application allows DoD vendors to submit and track Invoices and Receipt/Acceptance documents, if applicable, electronically. The Contractor is required to utilize this system when processing invoices and receiving reports, if applicable, under this contract/order, unless an exception at DFARS 252.232-7003(c) applies. The Contractor shall: (i) ensure an Electronic Business Point of Contact is designated in Central Contractor Registration (CCR) at http://www.ccr.gov. (ii) register to use WAWF at the https://wawf.eb.mil site, within ten (10) calendar days after award of this contract or modification. Step by step procedures to register are available at the https://wawf.eb.mil site. (iii) ensure review of the MSC WAWF Vendor Guide, available at the MSC site http://www.procurement.msc.navy.mil under the references section. In the event you have WAWF questions, contact the MSC WAWF point of contact (POC) at MSCHQ_WAWF@navy.mil. NOTE: The POC identified above is for WAWF issues only. Any other contracting questions/problems should be addressed to the Contracting Officer or other person identified in the contract to who questions are to be addressed. The Contractor is directed to use the Commercial Invoice format when processing invoices and receiving reports, if applicable. 0 This contract/order DOES require submission of Material Inspection and Receiving Reports (MIRR) DFARS Clause 252.246-7000; therefore, the vendor IS required to process receiving reports in WAWF under this contract/order. 1 This contract/order does NOT require submission of Material Inspection and Receiving Reports (MIRR) DFARS Clause 252.246-7000; therefore, the vendor is NOT required to process receiving reports in WAWF under this contract/order. The information contained in the table below is for WAWF purposes only. If any information included in these instructions, e.g., Ship to DoDAAC, contradicts information elsewhere in this contract, those other terms shall take precedence for any matter other than invoicing and receiving reports, if applicable. When entering the invoice into WAWF, the Contractor shall fill in the following DoDAAC fields or DoDAAC extensions exactly as shown in the table below. Fields that should not be filled in when entering the invoice into WAWF will be indicated below with the direction, "Leave Blank." WAWF Routing Table Contract Number To Be Determined Delivery Order To Be Determined Cage Code/Ext To Be Determined Pay DoDAAC N40442 Issue Date To Be Determined Admin By DoDAAC N40442 Issued By DoDAAC N40442 Ship To Code/Ext N62387 Ship From Code/Ext Leave Blank LPO DoDAAC Leave Blank Acceptor Email Address Leave Blank Inspect By DoDAAC/Ext Leave Blank In some situations the WAWF system will pre-populate the "Pay DoDAAC," "Admin By DoDAAC" and "Issue By DoDAAC." The Contractor shall verify that those DoDAACs automatically entered by the WAWF system match the information in the table above. If these DoDAACs do not match, then the Contractor shall correct the field(s). If Receiving Reports are required, ensure that the "Inspection" and "Acceptance" defaults of "destination" for both fields are not changed in the WAWF online interface. The CLINs on the WAWF invoice shall be entered exactly as set forth in the contract document including CLIN number (e.g. 0001), Quantity (may be adjusted for actual quantity or dollar value delivered and invoiced), and Unit Price (e.g. $1.00). The dollar amounts on each CLIN or SubCLIN on the WAWF invoice shall reflect final performance values, but in no instance can the dollar amount for each CLIN or SubCLIN exceed what is specified in the contract document. The Contractor shall bill to the lowest level, e.g., the SubCLIN level. The Quantity and Unit of Measure fields must be filled out exactly as indicated in the CLINs and SubCLINs to reduce the possibility of the invoice being delayed or rejected during processing. Before closing out of an invoice session in WAWF, but after submitting the document or documents, the Contractor will be given the option to send additional email notifications by clicking on the "Send More Email Notifications" link that appears on the page. The Contractor shall click on this link and add the acceptor's/receiver's email address in the first email address block and add any other additional email addresses desired in the following blocks. This additional notification to the Government is important to ensure the acceptor/receiver is aware that the invoice documents have been submitted into the WAWF system. BASIS FOR AWARD: Award will be made to the responsible, technically acceptable quoter, whose quote, conforming to the combined Synopsis/Solicitation, offers the lowest evaluated price. SHIP & BASE ACCESS Vendors are responsible for correctly submitting forms/applications. Vendors are encouraged to monitor email using "Request a Read Receipt" function and to confirm receipt of facsimile transmissions. Due to enhanced security measures, ship and base access is required for pre-award ship visits (e.g. ship-check) and for contract performance. Specifically the following permissions are required: 1. El Paso Intelligence Center (EPIC) personnel screening requirement 2. Base/Repair Facility Access Request 3. Vehicle Access Request 4. Ship Access List (vendor-provided) All forms are available for download on the MSC contracts webpage at http://www.msc.navy.mil. Click on "Contracts" in the upper right corner. "EPIC template" is under "Reference" subheading. Click on "Online Library of Common Documents" for all other forms. EPIC: Required for access to MSC vessels. Complete EPIC form strictly adhering to format requirements and forward to (CONUS East Coast repairs) MSFSC(underscore)EPIC(underscore)EAST@navy.mil and (CONUS West Coast and HI repairs) MSC.SSUSD.EPIC@NAVY.MIL. EPIC personnel screening requests are desired seven calendar days prior to performance start date. Requests will be managed as expeditiously as circumstances permit. Vendor will be notified by MSFSC of personnel who are denied access to the vessel. Base/Repair Facility Access: Permit is required to access Navy facilities. Base/Repair Facility Access Request is desired seven days prior to ship check or performance start date. Submit forms per the document instruction and to the Port Engineer. A courtesy copy (CONUS West Coast performance locations only) to Ermanno Magliulo, Engineering Director, at ermanno.magliulo@navy.mil will be appreciated. RAPIDGate® is being implemented for access to DoD facilities in CONUS, HI, Guam and Puerto Rico. Vendor is responsible to acquire RAPIDGate® status and destination base individual access badge(s) activation prior to performance start date. Delays that may result from inadequate planning are contractor responsibility. Vendor instructions and program information is available at http://www.RAPIDGate.com or tel. 877.727.4342. RAPIDGate® access requires (in succession) (1) Individual Base Commander approval for vendor to access base, (2) Successful vendor RAPIDGate® company annual enrollment, (3) Company employee individual enrollment and possession of RAPIDGate® identification badge for single base or multiple base (enterprise) access. Vendor is responsible to confirm that each employee held annual RAPIDGate® badge is active for the specific facility and performance period in accordance with RAPIDGate® User Agreement (http://www.RAPIDGate.com). Additional access permissions may be required such as Navy Base Point Loma "Enclave Access request form". Vehicle Access: Required for vehicle access to Navy facilities. Follow supplemental instructions on Base Access forms or base-specific vehicle access forms. Ship Access List* (Vendor-Provided): On company letterhead attachment via email, the vendor is required to provide the ship master (courtesy copy the Port Engineer) with an accurate, current list of performing personnel prior to being admitted aboard the vessel. Under no circumstances will a hand-delivered list be accepted.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/MSC/N322051/N40442-12-T-7515/listing.html)
 
Record
SN02797645-W 20120711/120709235455-e09cf4b4d8a953d7cf99ceff3abf96de (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.