SOURCES SOUGHT
66 -- Brand Name or Equal Amsco Century Steam Sterilizer - RFI-1105396
- Notice Date
- 7/23/2012
- Notice Type
- Sources Sought
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Health and Human Services, Food and Drug Administration, Office of Acquisitions and Grants Services, 5630 Fishers Lane, Room 2129, Rockville, Maryland, 20857-0001
- ZIP Code
- 20857-0001
- Solicitation Number
- FDA-RFI-1105396
- Archive Date
- 8/10/2012
- Point of Contact
- Juana Quinteros, Phone: 3018276764
- E-Mail Address
-
Juana.Quinteros@fda.hhs.gov
(Juana.Quinteros@fda.hhs.gov)
- Small Business Set-Aside
- N/A
- Description
- Brand Name or Equal Amsco Century Medium Steam Sterilizer, Transfer Car, Installation, Base year and 1 option year Service Maintenance Agreement, RFI in MS Word format. General Information: Document Type: Request for Information (RFI) Release Date: July 23, 2012 Response Date: July 26, 2012 at 4:30pm EST via e-mail to Contracting Specialist Contracting Office Address: Food and Drug Administration (FDA), Juana Quinteros Juana.Quinteros@fda.hhs.gov Contract Specialist Description: Brand Name or Equal Amsco Century Medium Steam Sterilizer, Transfer Car, Installation, Base year and 1 option year Service Maintenance Agreement. This is a Request for Information (RFI) to identify the capabilities of the marketplace of all interested parties. This request is for information and planning purposes only and shall not be construed as a solicitation or as an obligation on the part of the Food and Drug Administration (FDA) for any future solicitation. No official solicitation exists; therefore, please do not request a copy of a solicitation. If in the future an official solicitation is released, there is no guarantee that sources responding to this will be included on the source list. Telephone inquiries will not be accepted. The FDA makes no implied or in fact contract by issuing this RFI. Acknowledgement of receipt of responses will not be made, nor will respondents be notified of the FDA's view of the information received. Do not send any material that requires a non-disclosure agreement or that may be business sensitive. Responses received that include a non-disclosure agreement or identify information that is business sensitive will not be accepted. Responses to this notice will not be returned. According to FAR Part 10, Market Research, the results of the market research will be used to: (i) Determine if sources capable of satisfying the agency's requirements exist; (ii) Determine if commercial items or, to the extent commercial items suitable to meet the agency's needs are not available, non-developmental items are available that- (A) Meet the agency's requirements; (B) Could be modified to meet the agency's requirements; or (C) Could meet the agency's requirements if those requirements were modified to a reasonable extent; (iii) Determine the extent to which commercial items or non-developmental items could be incorporated at the component level; (iv) Determine the practices of firms engaged in producing, distributing, and supporting commercial items, such as type of contract, terms for warranties, buyer financing, maintenance and packaging, and marking; (v) Ensure maximum practicable use of recovered materials and promote energy conservation and efficiency; and (vi) Determine whether bundling is necessary and justified. (vii) Assess the availability of electronic and information technology that meets all or part of the applicable accessibility standards issued by the Architectural and Transportation Barriers Compliance Board at 36 CFR Part 1194. The extent of market research will vary, depending on such factors as urgency, estimated dollar value, complexity, and past experience. The contracting officer may use market research conducted within 18 months before the award of any task or delivery order if the information is still current, accurate, and relevant. Market research involves obtaining information specific to the item being acquired and should include- (i) Whether the Government's needs can be met by- (A) Items of a type customarily available in the commercial marketplace; (B) Items of a type customarily available in the commercial marketplace with modifications; or (C) Items used exclusively for governmental purposes; (ii) Customary practices regarding customizing, modifying or tailoring of items to meet customer needs and associated costs; (iii) Customary practices, including warranty, buyer financing, discounts, contract type considering the nature and risk associated with the requirement, etc., under which commercial sales of the products or services are made; (iv) The requirements of any laws and regulations unique to the item being acquired; (v) The availability of items that contain recovered materials and items that are energy efficient; (vi) The distribution and support capabilities of potential suppliers, including alternative arrangements and cost estimates; and (vii) Size and status of potential sources. Mission and Objectives: The following statement of work outlines the need and requirements for the purchase of Brand Name or Equal Amsco Century Medium Steam Sterilizer, Transfer Car, installation, Base year and 1 Option years of Service Maintenance. RFI Instructions: Please complete Part A, Specification Questionnaire, describing your company's capabilities; Part B, Size of Business and Part C, Estimated Dollar Value Range. Responses shall be:  identified with the RFI number ;  no more than five (5) pages in length;  not submit marketing materials;  submitted to the email as indicated above. FDA makes no implied or in fact contract by issuing this RFI. Acknowledgement of receipt of responses will not be made, nor will respondents be notified of the FDA's view of the information received. Part A. Technical Capability Specification Questionnaire: Is your company capable of providing Brand Name or Equal Amsco Century Medium Steam Sterilizer, Transfer Car, Installation, Base year and 1 option year Service Maintenance Agreement. Line Item Item Description 0001 Amsco Century Medium Steam Sterilizer 0002 Transfer Car 0003 Installation of new item and de-installation of old item 0004 Base Year-Service Maintenance Agreement 0005 Option Year 1- Service Maintenance Agreement Does this steam sterilizer have vacuum sterilization? Does this steam sterilizer have Chamber Dimensions 26" x 37.5" x 48"? Does this steam sterilizer have Power Requirements 120V, 1Ph; 460/480V, 3Ph? Does this steam sterilizer have 97% Vapor Quality Steam? Does this steam sterilizer have a hinged door and a left hand recessed one wall, single door? Does this steam sterilizer have Standard Brass and Copper Threaded Pipin? Does this steam sterilizer have Seismic Mounting? Does this steam sterilizer have a 48" Loading Car and Transfer Car for Hinged Platform? Does this steam sterilizer have an Installation of a Sterilizer? Does this steam sterilizer have a 1st-year Preventative Maintenance? Does this steam sterilizer have 2nd-year Comprehensive Preventative Maintenance? What is your customary practice for a warranty for this type of instrument? Part B. Size of Business The Government is seeking small business opportunities. State whether your company is a small business (and also state your under socioeconomic status), College/University, large business or a non-profit organization. Part C. Estimated Dollar Value Range Based on the government's mission, objectives, and scope of work, what dollar value range would you determine to be the most accurate rough estimate. Under $50,000.00 Over $50,000.00
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/FDA/DCASC/FDA-RFI-1105396/listing.html)
- Place of Performance
- Address: 22201 23rd Drive, SE, Bothell, Washington, 98021, United States
- Zip Code: 98021
- Zip Code: 98021
- Record
- SN02812174-W 20120725/120723235803-85abbf5bc64daccc3ac5b7e4743f074e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |