SOLICITATION NOTICE
65 -- Dialysis System
- Notice Date
- 8/15/2012
- Notice Type
- Combined Synopsis/Solicitation
- Contracting Office
- Western Regional Contracting Office, ATTN: MCAA W BLDG 9902, 9902 Lincoln Street, Tacoma, WA 98431-1110
- ZIP Code
- 98431-1110
- Solicitation Number
- W91YU0-12-T-0146
- Response Due
- 8/16/2012
- Archive Date
- 10/15/2012
- Point of Contact
- Angela Dexter, 253-968-4912
- E-Mail Address
-
Western Regional Contracting Office
(angela.dexter@amedd.army.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is solicitation W91YU0-12-T-0146, 0010217984 issued as a Request for Quotation (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-60 The associated North American Industrial Classification System (NAICS) code for this procurement is 339112 (Surgical and Medical Instruments Manufacturing), Size standard is 500 employees. This RFQ is being issued as Firm Fixed Price, UNRESTRICTED. All responsible sources may submit a quotation which shall be considered by the agency. These items/supplies are for use at Williams Beaumont Medical Center, El Paso, TX All responsible Contractors shall provide an offer for the following. Brand Name or Equal (B.Braun) CLIN 0001: Dialysis System, includes manuals and training, part number: Item Number 710200L, qty: 10; Unit issue: EA CLIN 0002: Accurate Dialysis Measurement System, Item Number 7102233, qty: 10; Unit issue: EA CLIN 0003: Pyrogen Filter Hardware, Item Number 7102102, qty: 10; Unit issue: EA CLIN 0004: Freight charges, qty: 1 Unit issue: EA SPECIFICATION: Physical size of machine60 in. H x 28 in. W x 22 in. D Dialysate Temperature Range :33 - 40 Profiling :User-definable near, Exponential Conductivity Range :12.5-16 mS/cm Profiling :Total Sodium and Bicarbonate User definable, Linear, Exponential Dialysate Flow Range :300 - 800 ml/min Profiling :User definable, Linear, Exponential Ultrafiltration Range :0 - 3,000 mlihr Profiling :User-definable, 20 Pre-set Profiles Extracorporeal Circuit Blood Flow Range :50 - 600 mlJrnin Settings :10 mLfmin increments Heparin Flow Range :1-10 mI/hr Settings :0.1 mlihr increments Profiling :User definable, Linear, Exponential Venous Pressure Range : 20 - 390 mmHg. Arterial Pressure :Pre- or Post-pump monitoring Range :-400 - +700 mmHg. Air Detection :Ultrasonic sensor on venous line Red Sensors :Detect blood in extracorporealcircuit to initiate an automatic heparin bolus at beginning of dialysis and stop blood pump at the end of dialysis Venous line - at air detector. EVALUATION OF FACTORS: Award will be made based on Technically Acceptable, Lowest price. The evaluated price will be the total price of the quote, Technical Factors are more important than Price. Price must be determined to be fair and reasonable. A.Equipment must have the capability of calculating real time URR (UREA REDUCTION RATION). B. Equipment must have 21 different variations of UF (Ultrafiltration) modeling options. C. Equipment must have the options for pre-program on the machines to initialize of the pre- rinse and testing. D. Must have only (1) chemical solution to perform within 30 minutes disinfection cycle E. Equipment shall have post -blood pump arterial pressure monitoring (PBE) F. Equipment shall have single needle mode for the continuation of treatment when an aceess clots G. Equipment shall have Arterial Bolus Administration, which utilizes the blood pump to measure the amount of saline infuse into the bloodlines. H. Pre-programmed and user -defined treatment files which can be set for UF, Nia, Bicarb, dialysate flow, temperature and heparin. I. Equipment shall have an auto-on/off time which allows the center to save time. J. Equipment shall touch screen combine with off-screen for blood pump operation, on/off and speed control is always available via the by hard keys K. Equipment shall have alarm conditions that can be muted and cleared via "Acknowledge" hard key. L. Equipment shall provide treatment parameters that are entered via the "Enter" hard key. The key must lights up when the user press to confirm an entry. The following provisions will be included in the established solicitation, 52.212-1 Instructions to Offerors-Commercial Items; Addendum to 52.212-1 Instructions to Vendors (LOCAL PROVISION 5004); 52.212-2 Evaluation-Commercial Items; Addendum to 52.212-2 Evaluation Criteria; 52.212-3 Offerors Representations and Certifications- Commercial Items. Offerors must complete FAR 52.212-3 Offerors Representations and Certifications- Commercial Items or do so on-line at http://orca.bpn.gov. The following FAR clauses apply to this acquisition, 52.204-7 Central Vendor Registration. 52.212-1 Instructions to Offerors- Commercial Item, 52.212-4 Contract Terms and Conditions Commercial Items; 52.212-5 Deviation Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Items, 52.219-28 Post Award Small Business Program Representation, 52.252-2, Addendum to 52.212-1 (Local Provision 5004), The following Addendum to FAR 52.212-4(c) (Local Clause 5003) will also be included in the agreement, UNILATERAL CHANGES 1. The Contracting Officer may unilaterally reduce and/or de-obligate any quantities not supplied/performed at the end of the Unilateral Modifications; The Government may make unilateral modifications considered administrative in nature. Clauses Incorporated by Reference. 52.204-10 reporting Executive Compensation and First -Tier Subcontract Award,52,211-6 Brand Name or Equal, 52.222-3, Convict Labor, 52.222-19 Child Labor Cooperation With Authorities And Remedies, 52.222-21, Prohibition of Segregated Facilities 52-222-26, Equal Opportunity, 52.222-35 Equal Opportunity for Special Disabled Veterans, 52.222-36, Affirmative Action for Workers with Disabilities, 52.222-37 Employment Reports on Special disabled Veterans, Veterans of the Vietnam Era, and Other eligible Veterans, 52.222-50 Combat Trafficking in Persons,52.222-54 Employment Eligibility Verification, 52.223-18 Contractor Policy to Ban Tex Messaging While Driving, 52.225-3 Buy American Act-Free Trade, Agreements, 52.225-13 Restriction on Certain Foreign Purchases, 52.228-5 Insurance -Work on Government Installation,52.233-3 Protest After Award, 52.233-4 Applicable Law For Breach of Contract Claim, 52.236-9 Protection of Existing Vegetation, Structure, Equipment, Utilities, and Improvement, 52.242-13 Bankruptcy. The following DFARS clauses apply, 252.203-7000 requirements Relating to compensation of Former DOD Officials, 252.203-7002 Requirement to Inform Employees of Whistleblower Rights, 252.204-7003 Control of Government Personnel Work Product, 252.212-7001 Deviation, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items; 252.225-7001, Buy American Act and Balance of Payments Program, 252.232-7003, Electronic Submission of Payment Requests, 252.247-7023, Transportation of Supplies by Sea 252.247-7023 with Alt III; 252.232-7010 Levies on Contract Payments 252.211-7003 Item Identification and Valuation. The full text version of FAR provisions and clauses may be accessed electronically at www.arnet.gov/far All vendors will be required to submit invoicing through the Wide Area Work Flow electronic invoicing (WAWF). Potential contractors must be registered in the System for Award Management (SAM's) to be eligible for award. The Sam's internet web site is http://www.sams.gov Place of Delivery: William Beaumont Army Medical Center 5005 N. Piedrass Street El Paso,TX 79920 Contact: Angela Dexter, Phone 253-968-4912, Fax 253-986-4091, Email angela.dexter@us.army.mil. ALL QUESTIONS SHALL BE SUBMITTED VIA EMAIL.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA13/W91YU0-12-T-0146/listing.html)
- Place of Performance
- Address: Western Regional Contracting Office ATTN: MCAA W BLDG 9902, 9902 Lincoln Street Tacoma WA
- Zip Code: 98431-1110
- Zip Code: 98431-1110
- Record
- SN02841305-W 20120817/120816001209-318d0dc8ce6d13a02805be87f8747b0a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |