- Description
- SALIENT CHARACTERISTICS- TOMOTHERAPY SYSTEM The tomotherapy system requires a detector, a phantom, and compatible software that meets or exceeds the following approximate specifications. a. DETECTOR Device type:Vented ionization chambers Detector design:cubic Number of detectors:729 Detector size:0.5 cm x 0.5 cm x 0.5 cm (0.125 cm ³) Detector spacing:10 mm center-to-center, 5 mm edge-to-edge Max. field size: 27 x 27 cm ² Max. measurement points:2916 (four measurements) Reproducibility:? ± 0.5% Dead time: zero Repetition rate: 200 ms Measured quantities: absorbed dose to water (Gy), absorbed dose rate to water (Gy/min) Resolution: 1 mGy or 1 mGy/min Measurement range: (0.5... 45) Gy/min Reference point: 7.5 mm below the surface of the array Housing material: GPR Dimensions: 30 cm x 42 cm x 2.2 cm (W x D x H) Weight: approx. 5.7 kg Power supply:(90... 265) VAC; (50... 60) Hz PC connection:RS232, Ethernet b. PHANTOM Design:Octagon-shaped solid body phantom with two exchangeable bottom parts (LINAC phantom with air cavity, CT phantom) Dimensions:diameter 32 cm, length 32 cm Weight:approx. 24 kg Material:Polystyrene (water equivalent within ~ 2%) Density:1.04 g/cm3 Extent of supply:LINAC & CT phantom, positioning device, merge 729 insert c. SOFTWARE COMPATIBILITY: The included tomotherapy system software must be compatible with the following computer system specifications. Operating system: Microsoft ® Windows ® (XP Professional, Vista ® Business x32/x64, Windows 7 Professional x32/x64) Processor:Multi-core processor Memory (RAM):2 GB Hard disk:500 MB of free space for application software 600 MB of free space for.NET Framework 4.0+ Screen resolution:1280 x 1024 Interfaces:Network interface Other:Windows ® Internet Explorer ® 8.0 or higher, Adobe ® Reader ® 7.0 or higher
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/8849bdb7b62f8ed8c55e30969bed0512)
- Document(s)
- Attachment
- File Name: VA240-12-Q-0206 VA240-12-Q-0206.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=441526&FileName=VA240-12-Q-0206-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=441526&FileName=VA240-12-Q-0206-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA240-12-Q-0206 VA240-12-Q-0206.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=441526&FileName=VA240-12-Q-0206-000.docx)
- Record
- SN02841318-W 20120817/120816001218-8849bdb7b62f8ed8c55e30969bed0512 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |