MODIFICATION
48 -- Rotary Electric Actuators
- Notice Date
- 8/15/2012
- Notice Type
- Modification/Amendment
- NAICS
- 333995
— Fluid Power Cylinder and Actuator Manufacturing
- Contracting Office
- M67001 MARINE CORPS BASE CAMP LEJEUNE - RCO Marine Corps Base Camp Lejeune, NC
- ZIP Code
- 00000
- Solicitation Number
- M6700112Q0279
- Response Due
- 8/17/2012
- Archive Date
- 9/17/2012
- Point of Contact
- Deborah Woleslagle 910-450-5405 Primary POC is Deborah Woleslagle (deborah.woleslagle@usmc.mil; 910-450-5405)
- E-Mail Address
-
ary
- Small Business Set-Aside
- Total Small Business
- Description
- The purpose of this amendment is to enhance competition for this commoodity purchase. The following changes are applied: 1. The NEW Extension due date is 17 Aug 2012, 8:00 A.M. EST. All interested vendor(s) shall submit their best quote by the due date and time. All vendor(s) who have previously submitted a quote shall re-submit by the new due date and time. 2. If vendor quoted a similar item other than the suggested brand name item, vendor shall clearly state how the like item meets each of the specified minimum characteristics required by the Government. A mere brochure is not sufficient. The minimum requirements include various options that may not come with standard features. The vendor shall clearly state each option as required under the minimum requirements. The Government's minimum requirements are: Removable Torque or Thrust bushing Modes of Operations: Motor and Manual Manual operation: Accomplished by the uses of a Handwheel and Declutch Lever. (Note: Declutch Lever shall be Padlockage to permit Motor operation only). ABSOLUTE POSITION ENCODER WITH SENSING CIRCUITS with Built-in Self-Test. (Note:Encoder shall measure valve position at all times) ELECTRONIC TORQUE SENSOR: (Adjustment from 40 to 100% of rating in 1% increments) (APT) Analog Position Transmitter: Provide (4-20 Ma) signal that is proportional to valve position. (ATT) Analog Torque Transmitter: Provide (4-20 Ma) signal that is proportional to rate output torque. Monitor Relay: Shall trip when the actuator is not available for remote operation. (Both N/O and N/C contacts to be included) LCD DISPLAY: Display valve position as percent of Open All calibrations of actuators shall be possible without removing any covers or uses of special tools. (ESD) Emergency Shut Down Provision shall be included in each actuator.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/USMC/M67001/M6700112Q0279/listing.html)
- Place of Performance
- Address: Freight Traffic Branch (Attn: Murlene Smith)
- Zip Code: Ash Street, Bldg 1118
- Zip Code: Ash Street, Bldg 1118
- Record
- SN02841416-W 20120817/120816001336-c40cf58b969f0d2ba43bd93d57c5afe9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |