Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 29, 2012 FBO #3931
MODIFICATION

66 -- Electro Dynamic Shaker

Notice Date
8/27/2012
 
Notice Type
Modification/Amendment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B129, Mail Stop 1640, Gaithersburg, Maryland, 20899-1640, United States
 
ZIP Code
20899-1640
 
Solicitation Number
SB1341-12-RQ-0663
 
Archive Date
9/30/2012
 
Point of Contact
Joni L Laster, Phone: 301-975-8397, Patrick K Staines, Phone: (301)975-6335
 
E-Mail Address
joni.laster@nist.gov, patrick.staines@nist.gov
(joni.laster@nist.gov, patrick.staines@nist.gov)
 
Small Business Set-Aside
N/A
 
Description
The purpose of this amendment (amendment II), is to respond to vendor questions as follows: Question: Do you have a list of test profiles that you need to run? Answer: The shaker(s) will be used in single-frequency constant-amplitude mode (sine mode) at frequencies ranging from 1 Hz to 2 kHz. Question: How many channels will be required including both control and monitoring? Answer: Closed loop control is required along with real-time readout of the shaker oscillation. The readout may be from a separate monitoring channel or from the control channel. Question: What test types will be required? Sine, Random, Shock, SRS, Time History Replication, etc.? Answer: Sine tests will be performed Question: The specifications sheet calls out a minimum of one accelerometer - do you need more than one? Are there certain specifications that you need the accelerometer to meet? Answer: The accelerometer is required as this is an essential part of the feedback control loop. More than one may be included by the manufacturer at their discretion (e.g. if this improves performance). The particular specifications of accelerometer(s) are not part of the RFQ. The important parameter for the technical evaluation will be the expected spectral purity and uniaxial character of the sine-force excitation, taking into account the accelerometer characteristics and all other parts of the control loop. Question: Documentation - can one copy of the manual be electronic (PDF) or do both copies need to be hard copy? Answer: One copy of the manual may be electronic Question: Can you provide information on the specimen that needs to be mounted on the table to understand the number of holes that will need to be drilled and tapped. Answer: A number of different specimens will be mounted, and will be coupled to the shaker armature with an adaptor plate. Therefore a typical set of mounting holes will be adequate. For example, a set of four 1/4-20 mounting holes on a bolt circle (e.g. diameter 3"), with a central 1/4-20 or 1/4-28 hole, would be adequate. The due date and time of August 30, 2012 @ 3pm EST (local time) remains unchanged. Only timely responses shall be considered for award.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SB1341-12-RQ-0663/listing.html)
 
Place of Performance
Address: 100 Bureau Drive, Gaithersburg, Maryland, 20899, United States
Zip Code: 20899
 
Record
SN02856199-W 20120829/120827235622-7980ad308371a9d622abc0c8889b04e4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.