SPECIAL NOTICE

41 -- Air Handler Upgrades

Notice Date
9/18/2012
 
Notice Type
Special Notice
 
NAICS
334512 — Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFLCMC/PKO - WPAFB, 1940 ALLBROOK DRIVE, WRIGHT-PATTERSON AFB, Ohio, 45433-5309, United States
 
ZIP Code
45433-5309
 
Solicitation Number
FA8601-12-P-0451
 
Archive Date
10/5/2012
 
Point of Contact
Matthew J. Strange, Phone: 9372570997
 
E-Mail Address
matthew.strange@wpafb.af.mil
(matthew.strange@wpafb.af.mil)
 
Small Business Set-Aside
N/A
 
Description
The United States Air Force, ASC/Operational Contracting Division, Wright-Patterson AFB, Ohio 45433-5344. This is a Sole Source synopsis published for informational purposes only. This proposed action is for the procurement of seven (7) Air Handler Upgrades: two (2) in-row coolers and five (5) precision chilled water cooling systems. The government intends to solicit and negotiate with only one source under the authority of FAR 6.302-1. This proposed procurement will be a Sole Source under North American Industry Classification System Code (NAICS) 334512. Size standard is 500 employees. The Newport Digital Lock-In-Radiometry System the only known item that satisfies the critical requirements. The required specifications for the Air Handler Upgrades with installation: Requirements for two (2) in-row coolers: • Air Handler must be compatible with Liebert remote monitoring and control devices • Air Handler must be able to interface with Liebert Site Scan Web • Must have a capacity of 40 kW, chilled water cooled • Must use R410A Refrigerant • Must have variable speed fans • Must have adjustable air supply baffles • Must have a graphical display • Must have the ability for: o Electric reheat o Humidification o Dual float condensation pump o Air filtration o Unit-to-unit communication (teamwork modes of operation) • Have the following Dimensions o Height: not to exceed 79 inches o Width: 24 inches (+/-1 inch acceptable) o Depth: 43 inches (+/- 1 inch acceptable) o Must not exceed 740 lbs Requirements for five (5) precision chilled water cooling systems: • Air Handler must be compatible with Liebert remote monitoring and control devices • Air Handler must be able to interface with Liebert Site Scan Web • Must have a capacity of 105 kW chilled water cooled • Must have EC plug fans • Must be A-frame coil design • Must have an infrared humidifier • Must have a graphical display • Must have the ability for: o Predictive humidity control o Air Filtration o Unit-to-unit communication (teamwork modes of operation) • Configuration must comply with EC plug fan under floor with down-flow supply • Must have electronic chilled water control valve • Have the following Dimensions o Height: not to exceed 72 inches o Width: 99 inches (+/-1 inch acceptable) o Depth: 35 5/8 inches (+/-1 inch acceptable) o Must not exceed 1420 lbs This notice of intent is not a request for competitive quotations. However, all responsible sources may submit a capability statement, proposal, quotation or exception to the intent to purchase on a sole source basis, which shall be considered by the Government if received within two (2) days of this notice. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. The Department of Defense (DoD) has determined the Central Contractor Registration (CCR) to be the single DoD registration for contractors who conduct business or who are interested in conducting business with the DoD. Contractors must be registered in CCR prior to award for solicitations issued after 21 May 1998. You may contact CCR at 1-888-CCR-2423, fax at 1-703-696-0213. DUNS/CCR website: http://ccr.edi.disa.mil/ccr/cgi-bin/query.pl.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/88 CONS/FA8601-12-P-0451/listing.html)
 
Place of Performance
Address: 1940 Allbrook Dr., WPAFB, Ohio, 45433, United States
Zip Code: 45433
 
Record
SN02888827-W 20120920/120919003044-009da65483210be371508abdaac145ae (fbodaily.com)
 