H -- FY-13 Annual Fire Alarm and Detection Inspections - Attachment

Notice Date
10/12/2012
 
Notice Type
Attachment
 
NAICS
541350 — Building Inspection Services
 
Contracting Office
Department of Veterans Affairs;VAMC Manchester;718 Smyth Road;Manchester NH 03104
 
ZIP Code
03104
 
Solicitation Number
VA24113Q0011
 
Response Due
10/22/2012
 
Archive Date
1/20/2013
 
Point of Contact
Richard Coutermarsh
 
E-Mail Address
Contract Specialist email
(richard.coutermarsh@va.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
STATEMENT OF WORK Annual Fire Alarm, and Detection (FAD) Inspections BACKGROUND: The contractor will provide labor, equipment and transportation to inspect FAD in Veterans Affairs Medical Center Manchester buildings. WORK REQUIREMENT: The contractor will inspect equipment in accordance with applicable National Fire Protection Association (NFPA) code. Tests include: 1. Test fire alarm initiating devices, fire detection and alarm equipment in accordance with (IAW) NFPA-72-1999 annually with 25 percent of devices inspected quarterly so that by contract year end all equipment has been tested. Equipment includes: a.Duct detectors, electro-mechanical release devices, heat detectors, manual fire alarm boxes and smoke detectors annual testing (TO INCLUDE SENSITIVITY TEST) 2. Test occupant alarm notification devices IAW NFPA 72-1999, including audible devices, speakers and visible devices. 3. Test automatic smoke detection air-handler shutdown devices IAW NFPA 90A-1999. CONTRACTOR REQUIREMENTS: The contractor shall have 5-years of experience in inspecting, testing and certifying hospital or commercial building fire alarm, detection and suppression systems. Contractor shall include pricing for (1) one base year plus (4) four additional option years. ADMINISTRATIVE REQUIREMENTS: The contractor will coordinate all work with the VAMC Safety Specialist. The contractor will provide a written report, with inspection sheets, indicating pass or failure status of all equipment and devices, with any written recommendations. QUANTITIES OF TESTED DEVICES: DeviceNumber of devices 1.a. Duct detectors40 1.a. Electro-mechanical release devices55 1.a. Heat detectors20 1.a. Manual fire alarm boxes120 1.a. Smoke detectors170 2. Audible and visible notification devices302 4. Air-handler shutdown devices20
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/MaVAMC608/MaVAMC608/VA24113Q0011/listing.html)
 
Document(s)
Attachment
 
File Name: VA241-13-Q-0011 VA241-13-Q-0011_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=497792&FileName=VA241-13-Q-0011-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=497792&FileName=VA241-13-Q-0011-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Manchester VAMC;718 Smyth Rd;Manchester, NH 03104-7007
Zip Code: 03104
 
Record
SN02913105-W 20121014/121012234146-b9fc66c40d308d140cd7c940dafbc490 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.