H -- FY-13 Annual Fire Alarm and Detection Inspections - Attachment
- Notice Date
- 10/12/2012
- Notice Type
- Attachment
- NAICS
- 541350
— Building Inspection Services
- Contracting Office
- Department of Veterans Affairs;VAMC Manchester;718 Smyth Road;Manchester NH 03104
- ZIP Code
- 03104
- Solicitation Number
- VA24113Q0011
- Response Due
- 10/22/2012
- Archive Date
- 1/20/2013
- Point of Contact
- Richard Coutermarsh
- E-Mail Address
-
Contract Specialist email
(richard.coutermarsh@va.gov)
- Small Business Set-Aside
- Total Small Business
- Description
- STATEMENT OF WORK Annual Fire Alarm, and Detection (FAD) Inspections BACKGROUND: The contractor will provide labor, equipment and transportation to inspect FAD in Veterans Affairs Medical Center Manchester buildings. WORK REQUIREMENT: The contractor will inspect equipment in accordance with applicable National Fire Protection Association (NFPA) code. Tests include: 1. Test fire alarm initiating devices, fire detection and alarm equipment in accordance with (IAW) NFPA-72-1999 annually with 25 percent of devices inspected quarterly so that by contract year end all equipment has been tested. Equipment includes: a.Duct detectors, electro-mechanical release devices, heat detectors, manual fire alarm boxes and smoke detectors annual testing (TO INCLUDE SENSITIVITY TEST) 2. Test occupant alarm notification devices IAW NFPA 72-1999, including audible devices, speakers and visible devices. 3. Test automatic smoke detection air-handler shutdown devices IAW NFPA 90A-1999. CONTRACTOR REQUIREMENTS: The contractor shall have 5-years of experience in inspecting, testing and certifying hospital or commercial building fire alarm, detection and suppression systems. Contractor shall include pricing for (1) one base year plus (4) four additional option years. ADMINISTRATIVE REQUIREMENTS: The contractor will coordinate all work with the VAMC Safety Specialist. The contractor will provide a written report, with inspection sheets, indicating pass or failure status of all equipment and devices, with any written recommendations. QUANTITIES OF TESTED DEVICES: DeviceNumber of devices 1.a. Duct detectors40 1.a. Electro-mechanical release devices55 1.a. Heat detectors20 1.a. Manual fire alarm boxes120 1.a. Smoke detectors170 2. Audible and visible notification devices302 4. Air-handler shutdown devices20
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/MaVAMC608/MaVAMC608/VA24113Q0011/listing.html)
- Document(s)
- Attachment
- File Name: VA241-13-Q-0011 VA241-13-Q-0011_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=497792&FileName=VA241-13-Q-0011-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=497792&FileName=VA241-13-Q-0011-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA241-13-Q-0011 VA241-13-Q-0011_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=497792&FileName=VA241-13-Q-0011-000.docx)
- Place of Performance
- Address: Manchester VAMC;718 Smyth Rd;Manchester, NH 03104-7007
- Zip Code: 03104
- Zip Code: 03104
- Record
- SN02913105-W 20121014/121012234146-b9fc66c40d308d140cd7c940dafbc490 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |