MODIFICATION
58 -- FMS Case KU-B-ULZ
- Notice Date
- 11/28/2012
- Notice Type
- Modification/Amendment
- Contracting Office
- ACC-APG - Aberdeen Division B, HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE, ABERDEEN PROVING GROU, MD 21005-1846
- ZIP Code
- 21005-1846
- Solicitation Number
- MARKET-SURVEY-5350-1
- Response Due
- 12/28/2012
- Archive Date
- 1/27/2013
- Point of Contact
- Tineka C. Davis, 443-861-5437
- E-Mail Address
-
ACC-APG - Aberdeen Division B
(tineka.c.davis.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- FOR MORE INFORMATION PLEASE CONTACT: Mitch Jacquay 443-861-5671 mitchell.a.jacquay.civ@mail.mil, Franklin Lee 443-861-5657 franklin.f.lee.ctr@mail.mil, Tony Blais 443-861-5672 anthony.w.blais.civ@mail.mil This is a revision to Market Survey 5350-1 to clarify the item description. FOR MORE INFORMATION PLEASE CONTACT Mitch Jacquay, EMAIL mitchell.a.jacquay.civ@mail.mil, Franklin Lee, EMAIL franklin.f.lee.ctr@mail.mil, Tony Blais EMAIL anthony.w.blais.civ@mail.mil This is a survey to locate suppliers or the actual manufacture of the Falcon 5000 Portable HPGe-Based Radionuclide Identifier (RID) and to supply OCONUS Training for up to 6 students. Presently, the only known source of this RID Canberra Industries, Inc. 800 Research Parkway, Meriden, CT 06450. less than BR greater than less than BR greater than **You must respond NO LATER than the Respond Date and Time Specifications for the Falcon 5000 Portable HPGe-Based Radionuclide Identifier is as follows: POWER Instrument Input 90-240 V ac; Universal ac adapter included. Batter y Type - Rechargeable Li-Ion; hot swappable. Batter y Configurations - - One internal batter y - four hours operation*. - Two internal batteries - eight hours operation*. Tablet Input 90-240 V ac; Universal ac adapter included. Battery Type - Rechargeable Li-Ion. Battery Configurations - - One internal batter y - three hours operation*. *Nominal value only. Actual run time depends on application specifics. DETECTOR GM TUBE - Internal Geiger-Mueller tube for high dose/count rate measurements. HPGe Detector - 60 x 30 mm (2.4 x 1.2 in.) (diameter x depth): relative efficiency approximately 20%. NEUTRON PROBE (Optional) - - Internal 3He tube with moderation. - Active Volume 8 x 2.54 cm (3.1 x 1 in.) (length x diameter). - Intrinsic neutron efficiency ~1% using an unmoderated 252Cf source. PHYSICAL DETECTOR DIMENSIONS - 400 x 347 x 155 mm (15.75 x 13.66 x 6.10 in.). DETECTOR WEIGHT - 15.5 kg (34.1 lb) with batteries not including the neutron probe. RUGGEDIZED TABLET DIMENSIONS - 284.5 x 209.6 x 40.6 mm (11.2 x 8.25 x 1.60 in.). RUGGEDIZED TABLET WEIGHT - 2.0 kg (4.45 lb). PERFORMANCE ENERGY RANGE - - HPGe - 30 keV - 3.0 MeV. - GM TUBE - 30 keV to 1.4 MeV. FWHM for BE2830 BEGe 20% detector - - less than 2.0 keV at 1332 keV. - less than 1.0 keV at 122 keV. Electrical Cooler - - TYPE - Pulse Tube Cooler. - TIME TO COOL DETECTOR - Three hours at 25 C (77 F). - WARRANTY - Five years; prorated. GPS MCA - - CHANNELS 256 - 8192 channels. - LIVE TIME CORRECTION - Live Time Correction (LTC) of spectral data. - Input Count Rate greater than 500 kcps. - PRESETS - Live time (or real time) preset 1 to 106 seconds. - High Voltage Inhibit - High voltage is automatically inhibited until the detector has reached operating temperature. CONTROLLER HARDWARE - Tablet PC. OPERATING SYSTEM - Windows XP. DISPLAY - 1024 x 768 color display. COMMUNICATION WITH INSTRUMENT - Wireless Communication - 802.11g Wi-Fi. - Security by WEP or WPA 32 bit encryption. (Wireless lockout available for Wired communication only mode). - Wired Communication - RJ-45 (Ethernet cable). SPECTRUM UPDATE - Two seconds per 8k spectra. SOFTWARE Functions Dose. Locate. Spectrum. Identification Functions. Dose Alarm (Continuously monitored with configurable set point, audio alert and visual indication). Genie 2000 Basic Spectroscopy and Gamma Analysis packages included. Radionuclide Identification algorithms are user configurable. Nuclide Library, Identification Algorithm, measurement geometry and other adjustable parameters are predefined in Genie 2000.ASF file (Analysis Sequence File). Nuclide Library - Configurable Library with Full Nuclide Editor (Default Library based on ANSI N42.34 specification). Secondary Analysis for SNM identifications to specify isotopic classification (RGPu, WGPu, HEU, DU...). ISOCS detector characterization available for numerical calibration and activity quantification of unique measurement geometries. 1Any other source that can provide the exact Portable HPGe-Based Radionuclide Identifier as described above must show either: Information/data/documentation which verifies that they have, in fact, previously manufactured the exact same item for the United States Government and as such can provide documentation of passing all First Article/Initial Production testing as described in the above mentioned specifications. 2A quality system to monitor all phases of manufacturing will be requested after contract award. 3. Identify whether you are a small or large business 4. If you are a small business then identify your subcategory, i.e. 8A, SDB, SDVOB, etc.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/f87465b9df3a14d9c4997dcadc3de43e)
- Place of Performance
- Address: ACC-APG - Aberdeen Division B HQ CECOM CONTRACTING CENTER, 6001 COMBAT DRIVE ABERDEEN PROVING GROU MD
- Zip Code: 21005-1846
- Zip Code: 21005-1846
- Record
- SN02938557-W 20121130/121128234548-f87465b9df3a14d9c4997dcadc3de43e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |