Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JANUARY 04, 2013 FBO #4059
MODIFICATION

58 -- Sony HD Camera

Notice Date
1/2/2013
 
Notice Type
Modification/Amendment
 
Contracting Office
421 North Main St, Leeds, MA 01053
 
ZIP Code
01053
 
Solicitation Number
VA241-13-Q-0222
 
Response Due
1/7/2013
 
Archive Date
7/6/2013
 
Point of Contact
Name: Kolleen Blanton, Title: Purchasing Agent, Phone: 4135844040, Fax: 4135823119
 
E-Mail Address
kolleen.blanton@va.gov;
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
AMENDMENT NOTICE:This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice.The solicitation number is VA241-13-Q-0222 and is issued as an invitation for bids (IFB), unless otherwise indicated herein.The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2005-63. The associated North American Industrial Classification System (NAICS) code for this procurement is 423620 with a small business size standard of 100.00 employees.This requirement is a [ Service-Disabled Veteran Owned ] set-aside and only qualified offerors may submit bids.The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2013-01-07 16:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com.FOB Destination shall be Augusta, ME 04330 The VHA NCO 01 - 631 - Northampton, MA requires the following items, Exact Match Only, to the following: LI 001, Product Number: PMW-10MD Sony HD Camera The PMW-10MD Full HD Medical Grade camera system combines outstanding image quality with the convenience of a built-in HD recorder. Its compact size and remote head design allow for simple integration into a wide variety of medical and scientific applications. The camera is equipped with 3 one half-inch (1920 x 1080) ExmorTM CMOS sensors, each delivering over 2 million pixels. Although small in size, the PMW-10MD delivers a superb video image, excellent sensitivity of F10, and a remarkable signal to noise ratio of 54 dB. Combine these specifications with a high horizontal resolution of 1,000 TV lines and a wide dynamic range of 450%, the PMW-10MD stands out as one of the best camera systems available for medical applications. Highlights: Compact camera head measures approximately 1.4: x 1.77" x 1.96: Designed for mounting above the OR table or on a surgical microscope using optional lenses and optical adapters, 1, EA; LI 002, Product Number: VUSB300 MEDICAP USB-300HD W/2 EACH FOOTSWITCH High Definition Medical Video Recorder The MediCap USB300 is the medical industry's easiest, most affordable high-definition recorder. Record up to two weeks of HD video on the internal hard drive or record directly to a convenient USB flash drive. Now you can experience easy, affordable HD video without all the hassles of DVD disks. Works with All Medical Cameras Record high-definition video from your endoscope, arthroscope, surgical camera, ultrasound, etc. Save to an internal hard drive or external USB flash drive. Can be accessed via any computer on your network. Intuitive Use It's so easy, most users never look at the manual. Just plug it in and go. You'll be recording videos within minutes of opening the box. Medical Grade With its steel case and fluid resistant front panel, the MediCap is built to withstand the rigors of the OR, and it's so compact it will fit on any cart. Learn More... Technical Specifications - Detailed information about the USB300's capabilities. Quick Demo - Shows how easy it is to use the USB300. Brochure - Information in a printer-friendly format. Available in several languages (see links to the left). Model Comparison - Feature-by-feature comparison of MediCap models. The MediCap USB300 can record in high definition and standard definition. If you only need standard definition, you may be interested in our USB200 model., 1, EA; LI 003, Product Number: LMD-3250 MEDICAL GRADE SONY LMD-3250 MD 32" MEDICAL GRADE LCD DISPLAY The LMD-3250MD 32? 1920x1080 HD monitor is the latest edition to Sony's comprehensive range of medical grade LCD displays. This 32? widescreen monitor* offers a 10-bit panel driver, 10-bit signal processing and Sony ChromaTRU color balance technology for ultra high performance. The LMD-3250MD displays a 1920x1080P full HD signal pixel-to-pixel enabling the purest reproduction of images captured by today?s HD surgical cameras. The LMD-3250MD was designed to be mounted on surgical carts, boom arms, walls or at a table top workstation with the optional SU-32FW/S stand. With built-in HD-SDI, DVI-D, HD15, RGB, Y/C, composite and SD-SDI inputs and one expansion slot, the LMD-3250MD can be integrated into any system environment. Built upon the same platform, the LMD-3250MD incorporates the same great features of the popular LMD-2450MD 24? model. The LMD-3250MD includes some new features such as enhanced side-by-side functions for better multi-modality performance, a full 10-bit panel driver that delivers an expanded color gamut, and a smaller power supply enabling easier operating room integration. Incorporating industry-leading Sony HD technology and design, the LMD-3250MD is the perfect addition to today?s HD operating rooms, enabling medical professionals to experience the full benefit of their HD surgical cameras. Highlights: Medical grade for the OR Ideal for displaying images from today's HD surgical cameras 32" full HD resolution (1920 x 1080 pixel) panel 16:9 widescreen flat panel LCD Multi-Picture display modes 10-bit signal processing Sony ChromaTRU? Color Balance Technology for superb color consistency VESA mount on boom arms, surgical carts or at a workstation Versatile inputs for out-of-the-box connectivity in almost any environment, 1, EA; Solicitation and Buy Attachments ***Question Submission: Interested offerors must submit any questions concerning the solicitation at the earliest time possible to enable the Buyer to respond. Questions must be submitted by using the 'Submit a Question' feature at www.fedbid.com. Questions not received within a reasonable time prior to close of the solicitation may not be considered.*** For this solicitation, VHA NCO 01 - 631 - Northampton, MA intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. An Offeror may submit a series of pricing bids, which descend in price during the specified period of time for the aforementioned reverse auction. VHA NCO 01 - 631 - Northampton, MA is taking this action in an effort to improve both vendor access and awareness of requests and the agency's ability to gather multiple, competed, real-time bids.All responsible Offerors that respond to this solicitation MUST submit the pricing portion of their bid using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a bid on www.FedBid.com.Offerors that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Offerors that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Offerors may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith bids, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process.Should offerors require additional clarification, notify the point of contact or FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com.Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Failure to comply with the below terms and conditions may result in offer being determined as non-responsive. New Equipment ONLY; NO remanufactured or "gray market" items. All items must be covered by the manufacturer's warranty. Bid MUST be good for 30 calendar days after close of Buy. This solicitation requires registration with the System for Award Management (SAM) prior to award, pursuant to applicable regulations and guidelines. Registration information can be found at www.sam.gov. The selected Offeror must comply with the following commercial item terms and conditions, which are incorporated herein by reference: FAR 52.212-1, Instructions to Offerors - Commercial Items, applies to this acquisition; FAR 52.212-3, Offeror Representations and Certifications - Commercial Items - the selected offeror must submit a completed copy of the listed representations and certifications; FAR 52.212-4, Contract Terms and Conditions - Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Items, paragraph (a) and the following clauses in paragraph (b): 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.225-13, 52.232-34. The full text of the referenced FAR clauses may be accessed electronically at https://www.acquisition.gov/far/. In addition to any VHA buy terms entered in FedBid, the Seller (Bidder) has reviewed and acknowledges any attached solicitation documents, item details, delivery schedule, and/or instructions to Seller (collectively referred to as requirements), and agrees to all terms and conditions set forth in the solicitation documents. While additional support documentation (e.g. Seller Attachments) may be requested, pricing shall be entered as a 'bid' in the reverse auction - offline pricing is not an acceptable bid. At the conclusion of the reverse auction, if attached to the buy, the apparent winning bidder shall be required to complete the solicitation documents prior to award. Shipping must be free on board (FOB) destination CONUS (Continental U.S.), which means that the seller must deliver the goods on its conveyance at the destination specified by the buyer, and the seller is responsible for the cost of shipping and risk of loss prior to actual delivery at the specified destination. Offeror must be registered in the Central Contractor Registration (CCR) database before an award can be made to them. If the offeror is not registered in the CCR, it may do so through the CCR website at http://www.ccr.gov.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NoVAMC/VAMCCO80220/VA241-13-Q-0222/listing.html)
 
Place of Performance
Address: Augusta, ME 04330
Zip Code: 04330-6796
 
Record
SN02957886-W 20130104/130102234116-98771b97d834aa33d97bd61622f3c47f (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.