Description
PLEASE NOTE: The Government has received a question that needs clarification. Question: Is this requirement a design-build project? Answer: No, this is NOT a Design Build Project. This is an Engineering Design and a Construction Period Services Requirement, using NAICS code 541330, Engineering Services. As stated in the original pre-solicitation, the solicitation will be posted to FBO.gov in the month of January 2013. The remainder of this document from the original pre-solicitation remains unchanged. This is a pre-solicitation notice ONLY. The government reserves the right not to solicit or award this requirement. DESCRIPTION The Contractor shall provide all A/E design and construction services, in accordance with VA Master Specifications and industry standards to provide: A complete and fully functional design for a chilled water plant capable of meeting the current cooling loads for conditioned space of the Cheyenne Veterans Administration Medical Center (VAMC). The system must achieve all of the following standards: The system shall meet current Cheyenne VAMC building cooling loads. The system shall be designed to accept the addition of all equipment necessary to support a 25% increase in capacity for future cooling loads. The system shall include chilled water mains, taps and routing to supply all areas of the facility. The system shall be fully integrated with current building systems. The system shall have sufficient redundancy to operate at full capacity with any single point of equipment failure or scheduled equipment maintenance. The system shall to the greatest extent possible be comprised of similar type, capacity and brand of equipment in order to maximize interoperability, interchangeability and minimize maintenance stocks. The system shall meet or exceed all current year Federal energy efficiency standards. The system shall include all software and hardware required to automatically monitor and operate the system in the most efficient manner possible. The system shall operate for twenty years without major equipment repair or replacement when operated within design parameters and subject to standard maintenance practices. The system shall include necessary water treatment and conditioning required to meet the twenty year lifetime standard. The system shall be designed in accordance with VA Specifications and meet all applicable standards, codes and guidelines as contained therein. The system shall resolve issues with existing 75-ton air-cooled chiller to include: Insufficient chilled water flow Major service due to long-term lack of use Revised control sequence to integrate chiller into BAS GENERAL: All design and work will conform to the current edition of the VA Master Specifications and VA Design Standards as published at the following site: www.cfm.va.gov, code of Colorado Regulations, EPA, ASHRAE, IBC 2003, NFPA and NEC building code and standards. Solicitation will be issued in the month of January 2013, on fbo.gov. SET-ASIDE: At this time, this will be a Service Disabled Veteran Owned Business, utilizing NAICS 541330 for Professional Engineering. CONTRACTING OFFICE ADDRESS: Department of Veterans Affairs ; Network Contracting Office, 19; 4100 East Mississippi Avenue #900; Glendale, CO 80246 PLACE OF PERFORMANCE: Cheyenne, Wyoming VAMC at 2360 East Perishing Blvd. Cheyenne, WY 82001 POINT OF CONTACT: Tracy Lynn Jackson Contract Specialist Tracy.jackson2@va.gov 303.603.3272
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VARMCCC/VARMCCC/VA25913R0199/listing.html)
 
Document(s)
Attachment
 
File Name: VA259-13-R-0199 VA259-13-R-0199_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=583479&FileName=VA259-13-R-0199-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=583479&FileName=VA259-13-R-0199-001.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;Cheyenne VAMC;2360 East Pershing Blvd.;Cheyenne, WY
Zip Code: 82001
 
Record
SN02964558-W 20130116/130114233814-a08fb4e2bc7dac5dc5c5ce31cad2f1ff (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.