DOCUMENT
66 -- 3d imaging system - Attachment
- Notice Date
- 2/7/2013
- Notice Type
- Attachment
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- Department of Veterans Affairs;North Texas Veterans Health Care Center;VISN 17 Network Contracting Activity;4500 S. Lancaster Road;Dallas TX 75216
- ZIP Code
- 75216
- Solicitation Number
- VA25713I0630
- Response Due
- 2/13/2013
- Archive Date
- 2/16/2013
- Point of Contact
- Brian Delaney
- E-Mail Address
-
7-0252<br
- Small Business Set-Aside
- Total Small Business
- Description
- The Department of Veterans Affairs, NCO17 Network Contracting Activity, 4500 S. Lancaster rd, Dallas Texas 75216 is conducting market research through this sources sought notice to seek sources for a 3D Cardiac Mapping System ( Carto 3 System.) The NAICS is 334510 and the classification code is 66. This is not a solicitation or request for quotation but an attempt to find who would be interested in this procurement. Items descriptions are listed below Item No.Model/ No.DescriptionQtyU/MUnit CostExt. Amount 1.CARTO 3 SYSTEM, MFR. BIOSENSE WEBSTER, Includes: Coolflow Irrigation pump w/interface cable and manual; baseline software license, location pad w/foot pedal, grounding cable, optic cable, power supply unit, patient interface unit, pin box, system cables, patch unit, Windows workstation computer w/two 24" high-resolution flat screen repeater monitors, user's manual, color inkjet printer and physician and staff training. 1EA 2.STOCKERT EP/IO KIT1EA 3.CART for CARTO 3 System1EA 4.CART for Carto 3 workstation1EA 5.SIEMENS BWI Communication Upgrade for Sequoia or X300 POTENTIAL VENDOR: BIOSENSE WEBSTER. POTENTIAL VENDOR PTR:VENDOR PRODUCT #: BWICOMMKIT1EA 6.CLINICAL MODULE PACKAGE FOR CARTO 3 SYSTEM: CARTOMERGE, Image integration software module; CARTOSOUND, software module; Complex fractional Atrial electrograms (CFAE) software module license to used with CARTO 3 system; CARTO 3 Premium service for one year. POTENTIAL VENDOR: BIOSENSE WEBSTER. POTENTIAL VENDOR PTR: VENDOR PRODUCT #: CMCSCFC31EA 7.GENERATOR, STOCKERT 70, with temp and power control modes POTENTIAL VENDOR: BIOSENSE WEBSTER POTENTIAL VENDOR PTR: VENDOR PRODUCT #: S7001EA 8.REMOTE CONTROL for Stockert 70 Generator POTENTIAL VENDOR: BIOSENSE WEBSTER. POTENTIAL VENDOR PTR: VENDOR PRODUCT #: S70191EA All items must be 100% compatible with the Biosense image integration software (CartoMerge and CartoSound Salient Characteristics: 1.The system must be compatible and capable of being interfaced with the current hemodynamic monitoring system, GE CardioLab. 2.Utilizes magnetic and current-based methods for visualizing the attached catheters inside the body. 3.The system can visualize up to five catheters at once from a variety of manufacturers and allows for diagnosis and treatment of atrial fibrillation and ventricular tachycardia arrhythmias. 4.The system can integrate with pre-acquired magnetic resonance (MR) and computed tomography (CT) images for catheter localization. 5.The system can integrate with intracardiac echo ultrasound. System includes an integrated radiofrequency (RF) generator for completing ablation procedures that are guided by the mapping equipment. 6.The system software controls and integrates the 3D mapping abilities and the cardiac ablation functions of the unit. 7.The system includes an irrigation unit. This sources sought announcement is not a request for proposals and the Government is not committed to award a contract pursuant to this announcement. The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses must be submitted via email to brian.delaney@va.gov: NLT 2/13/2013 1200 CST.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANTHCS/VANTHCS/VA25713I0630/listing.html)
- Document(s)
- Attachment
- File Name: VA257-13-I-0630 VA257-13-I-0630MOD1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=611226&FileName=VA257-13-I-0630-001.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=611226&FileName=VA257-13-I-0630-001.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA257-13-I-0630 VA257-13-I-0630MOD1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=611226&FileName=VA257-13-I-0630-001.docx)
- Record
- SN02981797-W 20130209/130207234604-4b5aad72871656cede439e3fa05b2555 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |