SOURCES SOUGHT
66 -- Bench Top Temperature Chamber - Package #1
- Notice Date
- 2/20/2013
- Notice Type
- Sources Sought
- NAICS
- 334513
— Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
- Contracting Office
- General Services Administration, Public Buildings Service (PBS), NEW Design & Construction Contracting (10PCC), 400 15th Street SW, Auburn, Washington, 98001-6599, United States
- ZIP Code
- 98001-6599
- Solicitation Number
- TBD-BenchTop
- Archive Date
- 3/16/2013
- Point of Contact
- Dwayne Cannon, Phone: 4042156787
- E-Mail Address
-
dwayne.cannon@gsa.gov
(dwayne.cannon@gsa.gov)
- Small Business Set-Aside
- N/A
- Description
- Specification of a Bench Top Temperature Chamber Commercial Off-the-Shelf", BenchTop temperature chamber, capabable of meeting the following performance characterisitics: •1. Performance Characteristics •1.1. Operational •1.1.1. Able to reach controlled temperatures from -40 Centigrade {C} to 200 C with a 40 Watt live load in the chamber. •1.1.2. Controlled by a programmable digital controller able to accept no less than ten separate programs. •1.1.3. Operate in either an automatic or manual mode. •1.1.4. Have an output that can activate an alarm. •1.1.5. Have multiple inputs to monitor temperature. •1.1.6. Provisions for an external data logger can record chamber temperature. •1.1.7. Have a sealable access port to the chamber, three to six inches in diameter. •1.1.8. Have self contained refrigeration system. No external facility coolant required. Although optionally, CO2 or LN from portable bottles may be used to assist. •1.1.9. The only utility service required will be electrical. •1.1.10. The chamber door will have a latching feature and will be vapor tight when latched. •1.2. Physical •1.2.1. The interior workspace shall be a minimum of 1 cubic foot with a minimum chamber dimension of 11 inches. •1.2.2. The unit shall be reasonably considered "bench top". •1.3. Electrical •1.3.1. Power requirements: no more than 20 amperes from a single phase, 120 Volt AC (nominal), 60 Hertz line. •1.3.2. The electrical connector shall be the appropriate NEMA rated plug. •1.3.3. The power cord shall be wired according to the National Electric Code and be a minimum of seven feet lon.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/10PDC/TBD-BenchTop/listing.html)
- Place of Performance
- Address: Hill AFB, 7879 Wardliegh Rd, Hill AFB, Utah, 84056, United States
- Zip Code: 84056
- Zip Code: 84056
- Record
- SN02991394-W 20130222/130220234531-f623fbd03baed420014ec6655e52d3fc (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |