H -- Base + 4 Option years, Space Pressure Differential Testing, GLA - Attachment
- Notice Date
- 2/20/2013
- Notice Type
- Attachment
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 22;4811 Airport Plaza Drive;Suite 600;Long Beach CA 90815
- ZIP Code
- 90815
- Solicitation Number
- VA26213Q0467
- Response Due
- 2/25/2013
- Archive Date
- 2/26/2013
- Point of Contact
- Michael L. Jensen
- Small Business Set-Aside
- Total Small Business
- Description
- Statement of Work Description: Quarterly Differential Pressure Testing Purchase Request: 691-13-1-5091-0018 Duration: Base Year plus four (4) Option Years. The exercise of an option year is not guaranteed, and will be dependent on several factors, including satisfactory performance under the Contract. Quote to Include: Base Year Pricing, as well as for each of the four option years. Set-Aside: This acquisition is being set-aside for small businesses. Evaluation Factors: Past performance, VA experience, and price; with past performance and VA experience being significantly more important than price. Work Location: VA West Los Angeles Medical Center 11301 Wilshire Blvd. Los Angeles, CA 90073 Work Site: Building 500 Location and Number of Rooms To Be Tested: Ground Floor: 1 First Floor: 4 Second Floor: 1 Third Floor: 5 Fourth Floor: 2 Fifth Floor: 10 Total Rooms 23 Requirements: 1.On a quarterly basis, Contractor shall provide all parts labor and materials required to measure and record the differential pressure relationship from the listed rooms to the adjoining space. 2.All work shall be performed by certified AABC technicians with current certification. 3.Work is to be performed Monday through Friday, 8:00AM through 3:00PM, and will be coordinated through the Engineering Department point of contact. 4.Most of the rooms are occupied by patients; the nursing staff will facilitate the testing in those areas. Some delay may occur due to patient needs and nursing activities, at no expense to the hospital. 5.4 (Four) bound copies of the report shall be provided to the Engineering Department within one week of completion. 6.The report shall contain the room number, the required pressure condition, and whether it is a positive or a negative room. The report shall include the actual pressure in reference to the adjacent space in inches water column, and also include the pressure in SI units, which are Pascals. 7.Calibration certificates and technician certification shall be provided in each report.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LBVANBC/VAMD/VA26213Q0467/listing.html)
- Document(s)
- Attachment
- File Name: VA262-13-Q-0467 VA262-13-Q-0467.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=625165&FileName=VA262-13-Q-0467-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=625165&FileName=VA262-13-Q-0467-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA262-13-Q-0467 VA262-13-Q-0467.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=625165&FileName=VA262-13-Q-0467-000.docx)
- Place of Performance
- Address: VA West Los Angeles Medical Center;Bldg. 500;11301 Wilshire Blvd.;Los Angeles, CA 90073
- Zip Code: 90073
- Zip Code: 90073
- Record
- SN02991461-W 20130222/130220234611-34c9e89979f88dbc23d5266408ecb146 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |