10 -- Rental of Temporary Switchgear at CRREL; Hanover , NH

Notice Date
3/5/2013
 
Notice Type
Award Notice
 
NAICS
532490 — Other Commercial and Industrial Machinery and Equipment Rental and Leasing
 
Contracting Office
USACE District, New England, 696 Virginia Road, Concord, MA 01742-2751
 
ZIP Code
01742-2751
 
Solicitation Number
W912WJ13Q0057
 
Response Due
3/4/2013
 
Archive Date
4/4/2013
 
Point of Contact
Michael Stearns, 978-318-8354
 
E-Mail Address
USACE District, New England
(michael.d.stearns@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Award Number
W912WJ-13-M-0100
 
Award Date
3/5/2013
 
Awardee
HARRIS, JAY (879377430) <br> 42 PROSPECT ST <br> NEWBURYPORT, MA 01950-2825
 
Award Amount
$96,480.00
 
Line Number
0001
 
Description
The contractor shall provide, install, secure, and maintain a minimum of 13.2kV, 1000 amp temporary main switchgear and 5ea 400 amp sub feeders to power all of the CRREL site, and disconnect all components in the existing switchgear cabinet. The current cabinet contains a switch for the main incoming feed and 5 sub feeders that branch out throughout the facility. The current switchgear and feeders are no longer able to hold SF6 insulating gas, and the switchgear and 5 sub feeders must be replaced. The contractor is required for all coordination with the power utility company, and may have a maximum power outage of 48 hours conducted during a weekend. The contractor shall be responsible to change over all power feeds to the facility to a temporary system while a permanent replacement is being fabricated and procured. The contractor shall be responsible to completely de-energize the existing cabinet to prepare it for demolition. The temporary unit shall be set up adjacent to the existing cabinet, and secured by temporary fencing provided by the contractor. The contractor shall be responsible for providing and installing the temporary switchgear within 45 days of contract award, and maintain the unit for six months with an option to extend on a monthly basis. The contractor shall be required to coordinate with a follow on contract to switch over all connections to the permanent replacement unit provided under a separate contract.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA33/W912WJ13Q0057/listing.html)
 
Record
SN03003684-W 20130307/130305234538-9a5cc7068ca4b5b7ba8a4db43a434f78 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.