Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 10, 2013 FBO #4124
MODIFICATION

Z -- DISA Critical Equipment Upgrade Design and Equipment Installation at DECC PAC Bldg 475, JBPHH, Hawaii

Notice Date
3/8/2013
 
Notice Type
Modification/Amendment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Honolulu, Attn: CECT-POH, Building 230, Fort Shafter, Hawaii, 96858-5540, United States
 
ZIP Code
96858-5540
 
Solicitation Number
W9128A-13-Z-0006
 
Archive Date
4/13/2013
 
Point of Contact
Tristin N. Matsuki, Phone: 808-835-4382, Kent Tamai, Phone: 808-835-4377
 
E-Mail Address
Tristin.N.Matsuki@usace.army.mil, kent.a.tamai@usace.army.mil
(Tristin.N.Matsuki@usace.army.mil, kent.a.tamai@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
THIS IS A SOURCES SOUGHT NOTICE and is for information purposes only. THIS IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS OR BIDS. The U.S. Army Corps of Engineers, Honolulu District, requests letters of interest from SMALL BUSINESS, 8(a), SERVICE DISABLED VETERAN OWNED SMALL BUSINESS (SDVOSB), HUBZONE, AND/OR WOMEN OWNED PRIME CONTRACTORS interested in performing work on a potential design-build construction solicitation for the DISA Critical Equipment Upgrade Design and Equipment Installation at DECC PAC Bldg 475, JBPHH, Hawaii. NO SOLICITATION IS CURRENTLY AVAILABLE. UNRESTRICTED Prime Construction Contractors are also invited to provide input on why the Government should not consider restricting this project as a set-aside. Project Description: To support Tier III data center equipment upgrades on the third floor of Building 475, Joint Base Pearl Harbor Hickam (JBPHH), Pearl Harbor, Hawaii for the Defense Enterprise Computing Center Pacific (DECC PAC). In support of additional computing rack equipment, deteriorated and under-utilized spaces on the third floor will be rehabilitated and reconfigured. Critical mechanical 1000 Ton air conditioning systems that provide infrastructure isolation from the rest of the facility to include: chillers, cooling towers, pumps, and piping will be installed in a 2N configuration. Rack containment systems for high density computing to include: in-row coolers, computer room air conditioners, power distribution units will be installed. The old and obsolete electrical distribution system on the third floor and service entrance will be upgraded and reconfigured to provide a dedicated 2N redundancy with medium voltage transformers and uninterruptable power supply to the computer equipment. Backup generators will be installed in the generator yard to provide a dedicated source of backup power for the computer equipment. The electrical systems to be designed and installed includes a UPS system in the 3.2MW range and a generator system in the 6MW range. The existing old and obsolete Substation K-6 on the ground floor will be replaced and reconfigured to provide power to the building. The existing old and obsolete generator in the generator yard will be replaced and reconfigured to provide backup power to the building. Project Magnitude: The estimated price range of this work is: $10M - $25M. Interested PRIME CONTRACTORS should submit the following: a. Narrative demonstrating experience in similar type of work. b. Bonding capability for a single contract action and aggregate of the interested small business prime contractor. c. DUNS/CAGE CODE. d. Indicate whether small business contractor is a socio-economic category of FAR PART 19. e. Expiration date in SAM.GOV. Narratives shall be no longer than two (2) pages. Email responses are required. Responses to this sources sought announcement will be used by the Government to make appropriate acquisition decisions. NO SOLICITATION IS CURRENTLY AVAILABLE. Responses are to be sent via email to tristin.n.matsuki@usace.army.mil and kent.a.tamai@usace.army.mil no later than March 29, 2013, 2:00 p.m. Hawaiian standard time. THIS NOTICE IS NOT A REQUEST FOR PROPOSALS, QUOTATIONS OR BIDS. It is a market research tool being utilized to determine the availability of potential qualified contractors before determining the method of acquisition. Please note that it is required that your company be registered in the System for Award Management (SAM), please see https://www.sam.gov/portal/public/SAM/ for additional information. In addition, this sources sought is not to be construed as a commitment by the government, nor will the government pay for any information solicited or delivered.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA83/W9128A-13-Z-0006/listing.html)
 
Place of Performance
Address: 1942 Gaffney Street, Suite 200, Pearl Harbor Naval Station, Hawaii, 96860, United States
Zip Code: 96860
 
Record
SN03007349-W 20130310/130308234226-957d3ad0ef3f014879aa26c4cff6786d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.