65 -- SURGICAL MICROSCOPE SYSTEM

Notice Date
3/28/2013
 
Notice Type
Presolicitation
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Defense Logistics Agency, DLA Acquisition Locations, DLA Troop Support - Medical, 700 Robbins Avenue, Philadelphia, Pennsylvania, 19111-5096, United States
 
ZIP Code
19111-5096
 
Solicitation Number
SPM2D113R0008
 
Archive Date
4/30/2013
 
Point of Contact
Sheila L Thorpe, Phone: 215-737-5978
 
E-Mail Address
Sheila.Thorpe@dla.mil
(Sheila.Thorpe@dla.mil)
 
Small Business Set-Aside
N/A
 
Description
BRAND NAME OR EQUAL SPECIFICATION Surgical Microscope System 1. SCOPE : This specification covers the requirements for a surgical microscope system for use during cataract and retina surgery. The surgical microscope system shall be Zeiss OPMI LUMERA 700 Surgical Microscope Zeiss part number 00000L7041776227 or equal with components listed in paragraph 3. The required surgical microscope system shall have the following salient characteristics. 2. SALIENT CHARACTERISTICS : At a minimum, the microscope system shall have the following characteristics/specifications:. •· The microscope system's optics shall be apochromatic. •· The microscope system shall have a magnification factor with a range of 0.4-2.4 •· The microscope system shall have a motorized zoom with a zoom ratio of 1:6 •· The microscope system shall have a motorized focus with a focus range of 70mm •· The microscope system shall have a motorized X-Y coupling with a maximum travel range of 61mmX61mm and with an automatic centering control. •· The microscope system shall have inclinable eyepiece head(s) with wide-field eyepieces (10x) •· The microscope system shall have objective lenses with f = 175mm •· The microspore system shall have an integrated keratoscope •· The microscope system shall have an integrated beam slitter •· The microscope system shall be fully HD video and HD video recording integrated. •· The microscope system shall have an integrated 22-inch HD Video Monitor •· The microscope system shall have an integrated HD camera. •· The microscope system shall have a floor stand. •· The microscope system's light source shall be a Xenon light source (with filters) or equal, that can provide a whiter, more natural light, higher contrast image of the surgical field than standard halogen illumination. •· The microscope system shall have a fully programmable wireless foot control panel. •· The microscope system shall have an integrated assistant's scope that can be used for training or active assistance. The assistant's scope shall have a motorized zoom control that can be synchronized with the microscope or controlled separately. The assistant's scope shall have inclinable eyepiece head(s) •· The microscope system shall have integrated components (non-contact type) that are capable to provide a retina wide-angle-viewing for retinal surgery. The system components shall have integrated inverters. The system components for retinal surgery shall include at least two different types of lens for retinal surgery (60D to 90D lens and 128D to 132D lens) 3. System configuration : Zeiss part number 00000L7041776227 includes the following Zeiss part numbers. Part number 3059539900000000. QTY: 1 ( Lumera 700 with floor stand) Part number 3026819100000000. QTY: 1 ( Asst scope with electric zoom Lumera 700) Part number 3026819023000000. QTY: 1 (SC Illumination Lumera 700 with assist scope) Part number 3049779023000000. QTY: 1 (SL Eye light source with HaMode Filter) Part number 3049709020000000. QTY: 1 (Foot control panel wireless (FCP WL) Part number 3049708760000000. QTY: 1 (6 m cable for foot switch) Part number 3059539037000000. QTY: 1 (22 in Monitor w/ bracket Lumera 700) Part number 3058109001000000. QTY: 1 (Asepsis set 22mm (6-pack)) Part number 3055420000000000. QTY: 2 (Wide field, push-in eyepiece 10X) Part number 3026519905000000. QTY: 1 (Objective, F=175 APO for Lumera 700) Part number 3058109001000000. QTY: 1 (Asepsis set 22mm (6-pack)) Part number 3055420000000000. QTY: 2 (Wide field, push-in eyepiece 10X) Part number 3058109001000000.QTY: 2 (Asepsis set 22mm (6-pack)) Part number 3058109017000000. QTY: 1 (Asepsis caps handgrip Lumera 700 (x6) Part number 3060700000000000. QTY: 1(Sterile drapes no 70 pack of 5) Part number 0000001055278000. QTY: 1 (Dust cover blue) Part number 3037979140000000. QTY: 2 (Electrical Inverter tube) Part number 3026819740000000. QTY: 1 (Integrated HD Camera) Part number 0000000021783971. QTY: 1 (RESIGHT 700- Optional package. This package includes: Part number 3027219030000000. QTY: 1 (Focus unit, RESIGHT 700, electrical) Part number 3027219100000000. QTY: 3 (Asepsis lens 60D for RESIGHT) Part number 3027219080000000. QTY: 3 (Asepsis 128D for RERSIGHT) Part number 3027219200000000. QTY: 3 (RESIGHT tray, sterilization, for lens holder) Part number 3027219070000000. QTY: 3 (Ster. lens holder RESIGHT for obj f=175 mm) Part number 3058109001000000. QTY: 1 (Asepsis set 22 mm (6-pack)) Part number 3027219040000000. QTY: 1 (Dovetail mount RESIGHT OPMI VISU/ Lumera) 3. Workmanship. The system and all accessories shall be free from defect that detract from its appearance or impair its serviceability. 4. Unit. Each (EA) System plus accessories, as specified, constitutes one unit. 5. REGULATORY REQUIREMENTS. 5.1 Federal Food, Drug, and Cosmetic Act. If the product covered by this document has been determined by the U.S. Food and Drug Administration to be under its jurisdiction, the offeror/ contractor shall comply, and be responsible for compliance by its subcontractors/suppliers, with the requirements of the Federal Food, Drug and Cosmetic Act, as amended, and regulations promulgated thereunder. In addition, the offeror/contractor shall comply, and be responsible for compliance by its subcontractors/suppliers, with the requirements of all other applicable Federal, State, and local statutes, ordinances, and regulations. 5.2 Recovered materials. The offeror/contractor is encouraged to use recovered materials in accordance with the Federal Acquisition Regulation (FAR) Subpart 23.403 to the maximum extent practical. 6. QUALITY ASSURANCE PROVISIONS. 6.1 Contractor certification. The contractor shall certify and maintain substantiating evidence that the product offered meets the salient characteristics of this brand name or equal specification, and that the product conforms to the producers' own drawings, specifications, standards, and quality assurance practices, and is the same product offered for sale in the commercial market-place. The government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract. 6.2 Metric products. Products manufactured to metric dimensions will be considered on an equal basis with those manufactured using inch-pound units. Dimensions and tolerances specified shall be converted using conversion tables contained in the latest revision of ASTM E 380. 7. PACKAGING. Preservation, packaging packing, labeling and marking. Shall be as specified in the contract and/or order. Specific requirements for this item are indicated in Section C, Description/Specification; general packaging and marking requirements are indicated in Section D, Packaging and Marking.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DLA/J3/DSCP-M/SPM2D113R0008/listing.html)
 
Place of Performance
Address: Ft. Meade, Maryland, 20755, United States
Zip Code: 20755
 
Record
SN03023576-W 20130330/130328235304-21018e6350599d53b8509ca17d6effde (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.