SPECIAL NOTICE
99 -- REPAIR MAINTENANCE OF TURNSTILE
- Notice Date
- 4/3/2013
- Notice Type
- Special Notice
- NAICS
- 332999
— All Other Miscellaneous Fabricated Metal Product Manufacturing
- Contracting Office
- N63394 Naval Surface Warfare Center, Port Hueneme 4363 Missile Way Port Hueneme, CA
- ZIP Code
- 00000
- Solicitation Number
- N6339413T5094
- Small Business Set-Aside
- N/A
- Description
- Naval Surface Warfare Center Corona (NSWC, Corona), Command Operations Department (CM) Code CM01, requires a Firm Fixed Price (FFP) contract to perform 5yr maintenance kit on PNG turnstile end units (2) and intermediate unit (1) which provide access control to the Daugherty Memorial Assessment Center. The government intends to award a sole-source, firm fixed priced contract to Automatic Control Systems. This procurement is commercial item IAW FAR Part 8.404. No solicitation will be issued but responsible sources may submit inquiries or request for information to marcella.webber@navy.mil or by phone at 951-273-4454. THE GOVERNMENT INTENDS TO SOLICIT AND NEGOTIATE WITH ONLY ONE SOURCE UNDER THE AUTHORITY OF FAR 6.302-1 FOR THIS PROCURMENT ACTION. INTERESTED PARTIES MAY IDENTIFY THEIR INTEREST AND CAPABILITY TO RESPOND TO THE REQUIREMENT, OR SUBMIT CAPABILITY STATEMENTS. THIS NOTICE OF INTEREST IS NOT A REQUEST FOR COMPETITIVE QUOTES OR PROPOSALS. BACKGROUND Building 547, the Daugherty Memorial Assessment Center (DMAC) is part of the Joint Warfare Assessment Laboratory that serves as an analytic fusion center for collaborative assessment of Navy, Army, Air Force, and Coalition war fighting performance and capability. The facility provides a secure environment with access control for the assessment of classified Navy, Army, and Air Force warfighting RDTE&A Training, and tactical operations data. Building 547 supports approximately 250 engineers and analysis ™s performing data analysis and training assessment each day requiring a strict logging a access control system to ensure the facility is properly armed and secured 24 hours, 7 days per week. The turnstiles which provides access control to the facility, log employee access and provides real-time occupancy counts to ensure the building is properly armed and secured when the building is unoccupied. SCOPE OF WORK: Perform 5yr maintenance kit on PNG turnstile end units (2) and intermediate unit (1). Maintenance shall be performed per the turnstile manufacturer recommendations. Materials include 5yr maintenance kit for end units (2) and 5yr maintenance kit for intermediate unit. PERORMANCE REQUIREMENTS Maintenance performed shall include: Inspect motors Replace motor crank bumper Replace large bumpers Replace and adjust all limit switches Replace shutter sliders (High glass only) Replace shutter guides (High glass only) Replace safety shutter assembly (High glass only) Replace plinth hardware Inspect clean and adjust all photocells Inspect and clean all Plexiglas Inspect all pictograms Inspect all electrical connections and cables Inspect motor crank set screws Inspect up and down main shaft set screws Inspect clips on rod Replace and adjust springs Replace fuses Measure main voltage (120V) Measure low voltage (24V) Inspect and tighten all bolts Add Locktite #242 on spring bolts Lubricate all bushings Lubricate springs Lubricate shutter guides (High glass only) Lubricate shutter pin (High glass only) Replace PLC battery Clean all the inside of the PNG with a vacuum Inspect door locks Inspect adjust and clean mobile glass Inspect adjust and clean fixed glass (High glass only) Inspect adjust and clean stainless steel housing Test PNG in entrance and exit
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVSEA/N63394/N6339413T5094/listing.html)
- Record
- SN03027238-W 20130405/130403234235-f3263cdbba3b9dba9abdba3859e62fe5 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |