Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 13, 2013 FBO #4158
SOURCES SOUGHT

61 -- RV STYLE GAS GENERATORS

Notice Date
4/11/2013
 
Notice Type
Sources Sought
 
Contracting Office
USPFO for Connecticut, 360 Broad Street, Hartford, CT 06105-3795
 
ZIP Code
06105-3795
 
Solicitation Number
0010309897
 
Response Due
4/25/2013
 
Archive Date
6/10/2013
 
Point of Contact
Thomas Tortorella, 860-524-4840
 
E-Mail Address
USPFO for Connecticut
(thomas.tortorella@ng.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
THIS SOURCES SOUGHT IS BEING ISSUED FOR PLANNING AND MARKET RESEARCH PURPOSES ONLY. THIS IS NOT A SOLICITATION. RESPONSES TO THIS NOTICE ARE NOT CONSIDERED AS OFFERS AND CANNOT BE ACCEPTED BY THE GOVERNMENT TO FORM A BINDING CONTRACT. THE GOVERNMENT WILL NOT BE RESPONSIBLE FOR ANY COSTS INCURRED BY INTERESTED PARTIES RESPONDING TO THIS SOURCES SOUGHT. The Connecticut National Guard is seeking small business contractors who are capable of providing and installing three (3) RV Style Gas Generators on RV style trailers located at a CT Army National Guard facility in Windsor Locks, CT 06096. Installation would include mounting and hard wiring the Generators into existing breaker boxes inspected and tested to Specifications. The required Specifications for the Generators are as follows: Rated Maximum Continuous Power Capacity (Gasoline): 6500 Watts Rated Voltage: 120 Rated Maximum Continuous Load Current 120 Volts: 54.2 Amps Main Line Circuit Breakers: 30 & 30 Amp Rated AC Frequency: 60Hz Engine RPM: 2571 Rotor RPM: 3600 Starter: 12 Vdc (Electric) Dimensions (L X W X H):NTE 33.7 X 21.5 X 16.8 Inches/NTE 856 X 546 X 427 Millimeters Weight: NTE 293 pounds Shipping: Included in Quote - Enclosed quiet, critical grade muffler. Muffler mounted inside the unit to prevent injuries while stationary or in transit. - Each unit will include service manuals and repair and replacement parts catalogs. - Due to the unique nature of this project the size and weight are parameters that are not flexible. This unit must be rugged and durable its sole purpose is to provide a dependable source of power. The generators will be used in a military environment. Any products proposed in response to this notice will be thoroughly evaluated to determine compliance with the specifications; therefore, submissions must include sufficient data (brochures, cutsheets, dimensions, product data, etc.) to make the determination. Products submitted that do not clearly demonstrate compliance will not be considered. In the event the generators can be obtained under General Service Administration (GSA) contract, please indicate the GSA contract number. This will be Small Business (SB) Set-Aside. The Government reserves the right to decide whether or not an SB Set-Aside is appropriate based on responses to this notice. The planned NAICS (North American Industry Classification System) code for this requirement is 335312 with a business size standard of 1,000 employees. Companies responding to this notice must indicate their size status. Note: NAICS 335312 is not waived under the Small Business Administration's Nonmanufacturer Rule, thus, if an SB Set-Aside is deemed appropriate, an SB will be required to furnish a product manufactured by itself or another SB. All interested Small Business concerns shall provide in writing, a notice stating their positive intention to submit a bid no later than 4 p.m., 25 April 2013. This notification, which shall not exceed five (5) typewritten pages, must include: (1) Positive statement of intent to bid. (2) A completed and signed Sources Sought Information Request Form (attached). Contractors should indicate their interest to the Contracting Officer, in writing as early as possible, but no later than 4 p.m., 25 April 2013. Information shall be provided by e-mail to Major Thomas Tortorella at thomas.e.tortorella.mil@mail.mil or mail at: USPFO For Connecticut (P&C), Attn: Major Thomas Tortorella, 360 Broad St., Hartford, CT 06105. E-mail is the preferred method. THIS SOURCES SOUGHT IS BEING ISSUED FOR PLANNING AND MARKET RESEARCH PURPOSES ONLY. THIS IS NOT A SOLICITATION. RESPONSES TO THIS NOTICE ARE NOT CONSIDERED AS OFFERS AND CANNOT BE ACCEPTED BY THE GOVERNMENT TO FORM A BINDING CONTRACT. THE GOVERNMENT WILL NOT BE RESPONSIBLE FOR ANY COSTS INCURRED BY INTERESTED PARTIES RESPONDING TO THIS SOURCES SOUGHT.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA06/0010309897/listing.html)
 
Place of Performance
Address: 14 Civil Support Team (CST) Route 75 Windsor Locks CT
Zip Code: 06096-1076
 
Record
SN03034674-W 20130413/130411235505-ea9238c634d1d1b64902a7f4d14eb3ba (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.