Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 26, 2013 FBO #4171
SOLICITATION NOTICE

12 -- Aircraft Hangar Wheeled Fire Suppression System 'This presolicitation was previously posted under FA8726-13-R-0012' - Responses to Questions

Notice Date
4/24/2013
 
Notice Type
Presolicitation
 
NAICS
339999 — All Other Miscellaneous Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFLCMC - Hanscom, 9 Eglin Street, Hanscom AFB, Massachusetts, 01731, United States
 
ZIP Code
01731
 
Solicitation Number
FA8726-13-R-0013
 
Point of Contact
John M. Lynch, Phone: 7812254117, Anthony A. Garcia, Phone: 781-377-1600
 
E-Mail Address
john.lynch@hanscom.af.mil, anthony.garcia@hanscom.af.mil
(john.lynch@hanscom.af.mil, anthony.garcia@hanscom.af.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Questions and Answers 001 Quantity of five (5) wheeled portable Fire Protection Systems for one (1) Group IV membrane fabric over metal truss hangar of area 14,160 sq ft (118'x120'x56'h) housing BD-700 commercial aircraft. An array of portable low-level, low-expansion foam system as found in National Fire Protection Association (NFPA) standard 409 pp. 9.14, 9.141, 9.14.7.4, 9.14.7.4.1, 9.14.7.4.2, 9.14.7.4.3 and 9.14.7.4.4 is required. Each of the five (5) Fire Protection Systems shall contain Flame Detection Sensors, audible/signal alarms, a manual safety over-ride (emergency), battery operation and charge indication, sensor over-ride, 120-gallon tank with pressure indicator of pre-mix CAFS foam solution with a range of 75 feet, manual and automatic turret operation, user manual publication, maintenance manual, and user orientation/training manual. Either the length or the width shall be less than 5 ft. The systems must have a 100 foot hose on a reel for hose operation, accessible independent of the turreted CAD system. In addition, the unit will require a wireless connection to activate the hangar Fire Alarm Control Panel, thus a transmitter and receiver is required, coded outputs shall be: alarm, status, low battery, and restore. The receivers are located within the hangar.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/ESC/FA8726-13-R-0013/listing.html)
 
Place of Performance
Address: Dover, Delaware, 19902, United States
Zip Code: 19902
 
Record
SN03044960-W 20130426/130424235124-d5b73b5c1ad4c9dc1340caf4bc35ea2b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.