SOURCES SOUGHT
H -- Integrity Testing of In Service and Out of Service Storage Tanks
- Notice Date
- 5/1/2013
- Notice Type
- Sources Sought
- NAICS
- 562910
— Remediation Services
- Contracting Office
- ACC - Pine Bluff Contracting Office (ACC-RI-Pine Bluff), ATTN: CCRC-ISP, 10-020 Kabrich Circle, Pine Bluff, AR 71602-9500
- ZIP Code
- 71602-9500
- Solicitation Number
- W911RP-13-R-0091
- Response Due
- 5/13/2013
- Archive Date
- 6/30/2013
- Point of Contact
- Retha J. Sprinkle, 870-540-3054
- E-Mail Address
-
ACC - Pine Bluff Contracting Office (ACC-RI-Pine Bluff)
(retha.j.sprinkle.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- Sources Sought Synopsis: The Contracting Division, Pine Bluff Arsenal (PBA), Pine Bluff, Arkansas 71602-9500, has a requirement for a contractor to provide all labor, equipment and supplies to perform all aspects of CAT-I tank testing and CAT-II tank residue removal/disposal of tank blinding and removal. The contractor must be certified in Steel Tank Institute (STI) standard SP001 to perform non-destructive integrity testing of in-service (CAT-1) above ground storage tanks (ASTs) to include the cleaning, blinding and removal of specific out-of-service (CAT-II) ASTs and underground storage tanks (USTs) at PBA. Without draining the tanks and without significant disruption of PBA's operation, the contractor will test and evaluate each AST and their respective valves and piping, in accordance with applicable Steel Tank Institute (STI) or American Petroleum Institute (API) standards with one of the following external, non-destructive integrity testing technique as stated within the Federal regulations 40 CFR 112.8 (6): (1) Hydrostatic testing (2) Radiographic Testing Ultrasonic testing (d) Acoustic testing or (e) another system of noon-destructive shell testing. After such testing completed, the contractor will replace or reinstall any tank insulation or out shell material that was removed during testing. The contractor shall develop a report of all findings; recommendations regarding the continued use of the tank and test results and will, at the completion of the project, submit the report, in electronic (compact disk) and hard copy format to PBA Environmental. If you are interest and can perform the above mention duties, please submit an email to rethe.j.sprinkle.civ@mail.mil. A determination has not been made as to what type of set-aide will be used if any; therefore, all interested parties must submit your interest in writing. The North American Industry Classification System NAICS code 562910 (19.0 M). This is not a solicitation; this is a Sources Sought Synopsis for interested contractors to submit their interest. All contractors must be registered in SAM's. Submit your responses with the following information: (1) Name of contractor ; complete Address and phone number; point of contact;, Small or Large or other Set-Aside type business; years of experience; NAICS Code, certification question (Yes or No). Questions may be sent via email. The Sources Sought Synopsis will be posted for ten (10 days only). Refer to the project as Integrity Testing of In/Out Service Storage Tanks (Reference No: W911RP-13-R-0091) Contract Specialist number is 870-540-3054.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/b6bc023516230ff7646e39b18a38a0b6)
- Place of Performance
- Address: ACC - Pine Bluff Contracting Office (ACC-RI-Pine Bluff) ATTN: CCRC-ISP, 10-020 Kabrich Circle Pine Bluff AR
- Zip Code: 71602-9500
- Zip Code: 71602-9500
- Record
- SN03049587-W 20130503/130501234324-b6bc023516230ff7646e39b18a38a0b6 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |