SOURCES SOUGHT
J -- Generator Repair
- Notice Date
- 5/16/2013
- Notice Type
- Sources Sought
- NAICS
- 811310
— Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Contracting Office
- Department of the Air Force, Air Force Global Strike Command, 341 CONS, 7015 Goddard Drive, Malmstrom AFB, Montana, 59402, United States
- ZIP Code
- 59402
- Solicitation Number
- F2W3D23127A001
- Archive Date
- 6/7/2013
- Point of Contact
- Gabriel L Zambrano, Phone: 4067314968, Deborah Ezop, Phone: 4067314011
- E-Mail Address
-
gabriel.zambrano.2@us.af.mil, deborah.ezop@malmstrom.af.mil
(gabriel.zambrano.2@us.af.mil, deborah.ezop@malmstrom.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- TROUBLESHOOT POWER TRANSFER EQUIPMENT 1. GENERAL: The purpose of this document Is to outline the minimum needs of the Government. The Contractor shall provide troubleshooting/minor programming and wiring adjustments In regards to the back-power controls at the designated building. 2. MINIMUM REQUIREMENTS: 2.1: Troubleshoot to determine the reason that the utility breaker on the transfer switch falls to close upon transfer from generator power to utility power during closed transition. Perform correction for any minor programming/wiring problems that are diagnosed. 2.1.1- Current Situation: The utility breaker attempts to close during transition, but falls to the open position. The breaker must then be manually closed under an open transition condition. This manual close has to be accomplished at the transfer switch, not the controller. The error message for the breaker merely Indicates "Breaker Failure". 2.2: Troubleshoot to determlne the reason that the generator is not communicating with the controller. Perform correction for any minor programming/wiring problems that are diagnosed. 2.2.1- Current Situation: When the generator Is on-line, the controller does not recognize and display this condition. 2.2.2- Current Situation: The controller Is not able to monitor the running conditions of the generator, e.g. temperature, oil pressure, etc. 3. SPECIFICS: 3.1-The Contractor shall be approved by Cummins Power Generation to work on the paralleling switchgear and controller. The controller is Cummins Model No. PCUL3001G- 580D, Serial No. F090006905. 3.2- Work will most likely be required to be performed on a Saturday or Sunday. 3.3-The Contractor's schedule must be flexible to allow the Government to obtain · permission to work In the building. It may take up to six to eight weeks to obtain permission. 3.4- Wiring diagrams will be provided for use by the successful bidder
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/2570f2a3c5377b74db78215414fe1d11)
- Place of Performance
- Address: Malmstrom AFB, Great Falls, Montana, 59402, United States
- Zip Code: 59402
- Zip Code: 59402
- Record
- SN03063917-W 20130518/130516234900-2570f2a3c5377b74db78215414fe1d11 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |