SOLICITATION NOTICE
J -- Emergency Generators Maintenance Services- McMillan Water Treatment Plant in Washington, DC
- Notice Date
- 5/17/2013
- Notice Type
- Synopsis
- NAICS
- 811310
— Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
- Contracting Office
- USACE District, Baltimore, 10 South Howard Street, Baltimore, MD 21203
- ZIP Code
- 21203
- Solicitation Number
- W912DR-13-T-0104
- Response Due
- 6/4/2013
- Archive Date
- 7/16/2013
- Point of Contact
- SHARLA ANDREWS, 4109622708
- Small Business Set-Aside
- Total Small Business
- Description
- The contract must supply maintenance service for three emergency power generator units located at McMillan Water Treatment Plant in Washington, DC. The service contract shall include the following: Provide a certified technician to 1) perform all manufacturer-recommended annual preventive maintenance on the emergency generator sets; 2) perform four (quarterly) inspections and testing of the generator sets under full plant load conditions. Furnish typewritten inspection reports containing all test results, technician's comments, and other pertinent information. Manufacturer, model number and serial number as well as the Washington Aqueduct's asset ID number assigned to each unit shall identify equipment in the report. Where applicable, reports shall include quote mark as-found quote mark and quote mark as-left quote mark conditions. All test results and reports shall be electronically sent to the owner no later than seven days after completion of service work. A copy of the technicians' field report shall be delivered to the owner upon completion of each service visit. Provide emergency maintenance service at the pre-determined hourly rate. Annual Preventive Maintenance: The annual Preventive Maintenance (PM) work shall include the tasks listed in the section below titled Annual Preventive Maintenance Tasks. The contractor shall provide a manufacturer-certified technician for an 8-hr day to perform the services on all three emergency generators. The technician shall replace oil, filter, and other items listed to be replaced under the contract. The annual PM work shall be scheduled at least 2-weeks in advance and the contractor's technician will perform the work on site from 7:00 am to 3:00 pm. One of the quarterly quote mark Inspection and Testing quote mark of the generators needs to be scheduled immediately following the annual PM work to ensure proper operation of the generator sets. Quarterly Inspection and Testing: The contractor shall provide a manufacturer-certified technician on a quarterly basis for a total of 4-days a year to inspect the generators and monitor their performance when they are exercised under plant load conditions. During this quarterly test run, the utility power to the plant will be shut off and the generators will be operated for a minimum of 4-hrs under full plant load. The quarterly test dates shall be scheduled at least 2-weeks in advance and the contractor's technician will be on site from 7:00 am to 3:00 pm on each of those dates to monitor the performance of the units, make necessary adjustment, provide training when required, and submit also technician's field report on the test. The technician's field report is separate from the formal report that needs to be submitted by the company within a week after completion of each quarterly test. In the event any of the generators fail to run when the utility power is out, the contractor shall provide emergency maintenance service on the units at the pre-determined hourly rate. The contractor shall report to McMillan plant, ready to start troubleshooting, within 4-hours after receipt of emergency service request. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (17-MAY-2013); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/USA/COE/DACA31/W912DR-13-T-0104/listing.html)
- Place of Performance
- Address: Washington Aqueduct's McMillan Water Treatment Plant 2500 First Street, NW Washington DC
- Zip Code: 20001
- Country: US
- Zip Code: 20001
- Record
- SN03065137-F 20130519/130518220435 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |