Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 22, 2013 FBO #4228
SOLICITATION NOTICE

65 -- PMG 115- Version 4.0 Advance RF Generator

Notice Date
6/20/2013
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
423450 — Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
 
Contracting Office
Western Regional Contracting Office, ATTN: MCAA W BLDG 9902, 9902 Lincoln Street, Tacoma, WA 98431-1110
 
ZIP Code
98431-1110
 
Solicitation Number
W91YU0-13-T-0143
 
Response Due
6/21/2013
 
Archive Date
8/19/2013
 
Point of Contact
kendre green, 253-968-4378
 
E-Mail Address
Western Regional Contracting Office
(kendre.green@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is solicitation W91YU0-13-T-0143, issued as a Request for Quotation (RFQ). This solicitation document and incorporated provisions/clauses are those in effect through Federal Acquisition Circular 2005-66. The associated North American Industrial Classification System (NAICS) Code for this procurement is 423450 (Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers), Size standard is 100 Employees. This RFQ is being issued as Firm Fixed Price, Unrestricted. All responsible sources may submit a quotation, which will be considered by the agency. These items/supplies are for use at Bassett Army Community Hospital (BACH), Ft Wainwright, Alaska. All Business Contractors shall provide an offer for the following CLINs and Specifications, for the following Brand Name or Equal (B. Braun): CLIN 0001: PMG-115-td Advanced RF Generator V4.0, qty: 1; Unit issue: EA CLIN 0002: V3 Multi-RF Module, qty: 1; Unit issue: EA CLIN 0003: Multi-Cooled RF Module, qty: 1; Unit issue: EA CLIN 0004: Peristaltic Pump, qty: 1; Unit issue: EA CLIN 0005: Sinergy Connector Cable, qty: 1; Unit issue: EA CLIN 0006: Transdiscal Cooled RF Y Connector Cable, qty: 1; Unit issue: EA CLIN 0007: 20G, 100M Straight RF Probe, qty: 4; Unit issue: EA CLIN 0008: 20G, 100M Straight RF Probe, qty: 8; Unit issue: EA CLIN 0009: One Day Training, qty: 1; Unit issue: EA CLIN 0010: On-Site Clinical Support, qty: 1; Unit issue: EA SPECIFICATIONS: Impedance Measurement Impedance 25 - 1000 10%, 10 1001 - 3000 20%, 10 Multi-RF Mode: Accuracy subject to condition that impedances of all other probes are within 100-1000 ; accuracy defined at ambient temperature of 25 C. Stimulation Stimulation Amplitude Ranges Voltage Mode: 0.00 - 10V, 0.01 V increments Current Mode: 0.00 - 10 mA, 0.01 mA increments Stimulation Rate 1shot, 2, 5, 10, 20, 50, 75, 100, 150, 180, and 200 Hz Stimulation Pulse Duration 0.1, 0.2, 0.5, and 1.0 ms RF Output Frequency 460.8 kHz 1%, quasi-sinusoidal Maximum Power 50 W Maximum Channels 1-4 User Selectable Measurement Accuracy Power 0.25 W, 5% Temperature 3 C Elapsed Time 1 s/min Timer Standard RF Mode 10 s - 900 s (depending on mode) Multi-RF Mode 10 s - 900 s (depending on mode) TRANSDISCAL* Mode 1 - 30 min Cooled-RF Mode 15 s - 30 min Multi Cooled RF Mode 15 s - 30 min IDL Mode 30 s - 20 min RFA Mode 1 - 30 min Mechanical Specifications Size 9.5 quote mark x 12.5 quote mark x 14.0 quote mark (25 cm x 32 cm x 35 cm) maximum Weight 16.5 lb (7.5 kg) maximum Environmental Specifications Operational Temperature 10 C to 35 C Storage Temperature -40 C to 70 C Humidity 20 % to 95 % non-condensing PC Compatibility RS232 port allows for data downloading with DATASTREAM* data recording software The KIMBERLY-CLARK ADVANTAGE* EVALUATION OF FACTORS: Award will be made based on Technically Acceptable, lowest price. Sellers MUST enter exactly what they are quoting to include: make, model and description in order for their quote to be considered. Buyer will evaluate quote mark equal items quote mark on the basis of information furnished by the Seller and identified in the quote. The evaluated price will be the total price of the quote. Technical Factors are more important than Price. Price must be determined to be fair and reasonable. A. Equipment MUST be Software Upgradable The following Provisions / Clauses are applicable: The following provisions will be included in the established solicitation, 52.212-1 Instructions to Offerors-Commercial Items; Addendum to 52.212-1 Instructions to Vendors (LOCAL PROVISION 5004); 52.212-2 Evaluation-Commercial Items; Addendum to 52.212-2 Evaluation Criteria; 52.212-3 Offerors Representations and Certifications- Commercial Items. Offerors must complete FAR 52.212-3 Offerors Representations and Certifications- Commercial Items or do so on-line at http://sam.gov. The following FAR clauses apply to this acquisition, 52.204-7 Central Vendor Registration. 52.212-1 Instructions to Offerors- Commercial Item, 52.212-4 Contract Terms and Conditions Commercial Items; 52.212-5 Deviation Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Items, 52.219-28 Post Award Small Business Program Representation, 52.252-2, Addendum to 52.212-1 (Local Provision 5004), The following Addendum to FAR 52.212-4(c) (Local Clause 5003) will also be included in the agreement, UNILATERAL CHANGES 1. The Contracting Officer may unilaterally reduce and/or de-obligate any quantities not supplied/performed at the end of the Unilateral Modifications; The Government may make unilateral modifications considered administrative in nature. Clauses Incorporated by Reference. 52.204-10 reporting Executive Compensation and First -Tier Subcontract Award, 52.211-6 Brand Name or Equal, 52.222-3, Convict Labor, 52.222-19 Child Labor Cooperation With Authorities And Remedies, 52.222-21, Prohibition of Segregated Facilities 52-222-26, Equal Opportunity, 52.222-35 Equal Opportunity for Special Disabled Veterans, 52.222-36, Affirmative Action for Workers with Disabilities, 52.222-37 Employment Reports on Special disabled Veterans, Veterans of the Vietnam Era, and Other eligible Veterans, 52.222-50 Combat Trafficking in Persons, 52.222-54 Employment Eligibility Verification, 52.223-18 Contractor Policy to Ban Tex Messaging While Driving, 52.225-3 Buy American Act-Free Trade, Agreements, 52.225-13 Restriction on Certain Foreign Purchases, 52.228-5 Insurance -Work on Government Installation, 52.233-3 Protest After Award, 52.233-4 Applicable Law For Breach of Contract Claim, 52.236-9 Protection of Existing Vegetation, Structure, Equipment, Utilities, and Improvement, 52.242-13 Bankruptcy. The following DFARS clauses apply, 252.203-7000 requirements Relating to compensation of Former DOD Officials, 252.203-7002 Requirement to Inform Employees of Whistleblower Rights, 252.204-7003 Control of Government Personnel Work Product, 252.212-7001 Deviation, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items; 252.225-7001, Buy American Act and Balance of Payments Program, 252.232-7003, Electronic Submission of Payment Requests, 252.247-7023, Transportation of Supplies by Sea 252.247-7023 with Alt III; 252.232-7010 Levies on Contract Payments 252.211-7003 Item Identification and Valuation. The full text version of FAR provisions and clauses may be accessed electronically at www.arnet.gov/far All vendors will be required to submit invoicing through the Wide Area Work Flow (WAWF) electronic invoicing system. Potential contractors must be registered in the System for Award Management (SAM's) to be eligible for award. The Sam's internet web site is http://www.sam.gov. Place of Delivery: Bassett Army Community Hospital 4076 Neely Road Ft Wainwright, AK 99703 Contact: Kendre Green, Purchasing Agent, Phone 253-968-4378, Fax 253-986-4091, Email: kendre.m.green.civ@us.army.mil. ALL QUESTIONS MUST BE SUBMITTED VIA EMAIL.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA13/W91YU0-13-T-0143/listing.html)
 
Place of Performance
Address: Western Regional Contracting Office ATTN: MCAA W BLDG 9902, 9902 Lincoln Street Tacoma WA
Zip Code: 98431-1110
 
Record
SN03095201-W 20130622/130620235300-8f5b56fbdf825aeae7b6d1ac24c1f9a4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.