Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 13, 2013 FBO #4249
SOLICITATION NOTICE

66 -- Toxic Gas Instrumentation and Industrial Gas Analyzer

Notice Date
7/11/2013
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
ACC - Warren (ACC-WRN)(DTA), ATTN: AMSTA-AQ-AMB, E Eleven Mile Road, Warren, MI 48397-5000
 
ZIP Code
48397-5000
 
Solicitation Number
0010343728
 
Response Due
7/15/2013
 
Archive Date
9/9/2013
 
Point of Contact
Jeremy Mueller, 586-282-6201
 
E-Mail Address
ACC - Warren (ACC-WRN)(DTA)
(jeremy.t.mueller.mil@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Quantity: One (1) Toxic Gas Instrumentation Equipment must meet the following minimum requirements: Measure up to five gas components by combining the different technologies into one unit. 4 ranges per channel Dynamic Auto ranging 1:10 or more Auto calibration Zero and span stability by auto zero and automatic gain control (AGC) without span gas Pressure compensated Sample flow rate measurement Analog, digital and serial I/Os. Enclosure -Configurable for 19 quote mark rack / table-top enclosure Vibration Decoupling - Optical bench without vibration decoupling Gas ComponentsMinimum Ranges Maximum Ranges Ammonia NH3 0 - 100 ppm 0 - 30% Carbon dioxide CO2 0 - 5 ppm 0 - 100% Carbon monoxide CO 0 - 10 ppm 0 -100% Hexane C6H14 0 - 300 ppm 0 - 9,000 ppm Methane CH4 0 - 300 ppm0 - 100% Nitric dioxide NO2 0 - 10 ppm 0 - 1,000 ppm Nitric oxide NO 0 - 150 ppm 0 - 100% Nitrous oxide N2O 0 - 200 ppm 0 - 2,000 ppm Oxygen O2 0 - 1% 0 - 100% Sulphur dioxide SO2 0 - 25 ppm 0 - 80% Sulphur hexafluoride SF6 0 - 5 ppm 0 - 2% Water vapor H2O 0 - 1,000 ppm 0 - 10% Quantity: One (1) Industrial Gas Analyzer Equipment must meet the following minimum requirements: - 0.5cm-1 Industrial FTIR, MCT Detector, ZnSe Optics, Dual ADC: - ZnSe (Zinc Selenide) interferometer with selectable resolution from 0.5cm-1 to 32cm-1. - ZnSe beam splitter with Ge coating for moisture protection - Dual ADC for enhanced signal to noise - MCT (Mercury Cadmium Telluride) detector, 1x1 mm element size, 2 to 18 micron range - 1650 K IR source; silicon carbide glower - ZnSe (Zinc Selenide) windows for resistance to moisture damage - All interface optics gold coated for high throughput -Separate input and output ports for the collimated beam, allowing use of externally mounted sample interfaces. Peripheral Device Package: Includes power supply, fiber optic distribution board, numerical display for one pressure sensor, temperature and limit controllers for one heater band, and redundant high current relays. Control temperatures to 240 Celsius, monitor pressure with a voltage transducer, and allow data transfer to computer for recording information on spectra file headers. Temperature controller accuracy 1% full scale + ILSD (40 degrees F to 500 degrees F). Communicates with data system via fiber optic cable (3 meter length required), with spectrometer via 25 pin ribbon cable, and with up to four valve manifolds via 15 pin connectors. 15cm Pathlength ZnSe Gas Cell: Nominal path length is 15cm in single pass transmission cell. Pressure Transducer, Voltage: 0-30 psia. Calibrated and temperature-compensated industrial pressure transducer. Single Band Heating: For high and low temperature applications. Stainless steel with MICA insulation and including built in dual J type thermocouples for applications up to 240 degrees C. Optical Interface: Focused beam. Consists of two light guides and two parabolic mirror assemblies.. Spectrometer Software: Both dual and single ADC. Featuring automated data collection and real-time spectral analysis with alarm outputs which is implemented by means of an advanced multivariate algorithm. Spectra and quantitative results may be archived; and time of collection, concentration, and error analysis data may be later exported to any spreadsheet program, Excel, Lotus, etc. or used to generate concentration versus time plots for individual components. Concentration data can automatically be corrected for temperature and pressure changes, and mass emissions can be calculated in near real time. FTIR Spectrometer Software: Windows based application featuring a user friendly graphical interface. Includes all essential spectral data manipulation functions including baseline correction, spectral region zap, subtraction, derivatives, smoothing, offset, truncate, scale, peak picking and measurement, ATR correction and conversion between absorbance, transmittance and diffuse reflectance. Computer System with minimum specification: P4 CPU, 3.0GHz, 512 MB SD RAM, combo CDRWDVD, 80GB HD, 17 quote mark flat panel LCD monitor with keyboard, mouse and loaded with Windows XP PRO. Fully tested with FTIR software packages. Offeror shall include all shipping charges and deliver supplies F.O.B. DESTINATION to the following address: TACOM LCMC Central Receiving Dock, Bldg 249 6501 E. Eleven Mile Rd Warren, MI 48397-5000 Offeror shall deliver requirement by the following date: 120 Days After Award B.This acquisition is unrated under the Defense Priorities and Allocations System (DPAS). C.Bids must be received by ACC-WRN no later than 1500 hrs EST, 15 Jul 2013. Email bid to jeremy.t.mueller.mil@mail.mil. Offeror must be registered in System for Award Management (SAM) prior to receiving an award. Refer to website https://www.sam.gov/portal/public/SAM/
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/c94bdca025c151ea713eaa709742e44d)
 
Place of Performance
Address: ACC - Warren (ACC-WRN)(DTA) ATTN: AMSTA-AQ-AMB, E Eleven Mile Road Warren MI
Zip Code: 48397-5000
 
Record
SN03113844-W 20130713/130711235217-c94bdca025c151ea713eaa709742e44d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.