Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 18, 2013 FBO #4254
MODIFICATION

59 -- Vector Network Analyzer

Notice Date
7/16/2013
 
Notice Type
Modification/Amendment
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFNWC/PZI - Kirtland, Installation Contracting Division, AFNWC/PZI, 8500 Gibson SE, Bldg 20202, Kirtland AFB, New Mexico, 87117-5606, United States
 
ZIP Code
87117-5606
 
Solicitation Number
F2KBAB319A001
 
Point of Contact
Tyler Wallace Macdonald, Phone: 5058460144, Rafaela Kovacs, Phone: 5058467691
 
E-Mail Address
tyler.macdonald@kirtland.af.mil, rafaela.kovacs@kirtland.af.mil
(tyler.macdonald@kirtland.af.mil, rafaela.kovacs@kirtland.af.mil)
 
Small Business Set-Aside
N/A
 
Description
An interested vendor had asked the following questions in regards to the solicitation. The Government has provided the below responses to said questions. Please incorporate any changes to quotes provided in light of the aforementioned responses: 1. Is the solicitation for a wideband solution (10 MHz to 110 GHz with 1 mm coaxial connector) or banded solution (75-110GHz with output WR-10 waveguide)? ---Banded Solution (75-110GHz with output to WR-10 Waveguide) 2. Does the system have to support both banded and wideband operation? ---Banded Solution only 3. Will there be any measurements conducted between 24 GHz to 40 GHz; 40 GHz to 50 GHz; and/or 50 GHz to 67 GHz? ---Measurements will be performed in the 75-110GHz range only. 4. Are the performance data and system data parameters to be provided with the converters or are data without the converters admissible? ---With the converters (probably?). With the exception of the Harmonic power spec (which is for the base unit), we would prefer that the integrated system (with the converters) meet the requested specs. If, for some reason, none of the vendors are unable to meet these specifications, the bids will be evaluated strongly on which comes closest to the desired specs., 5. Are these data (item 7, 9,10) specified value or typical value? and under what conditions? ---Typical values under controlled laboratory conditions. 6. Is interim performance data admissible? ---It is unclear what this means. What does the vendor define as interim performance?
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/377CONSKOC/F2KBAB319A001/listing.html)
 
Place of Performance
Address: Kirtland AFB, NM, Albuquerque, New Mexico, 87117, United States
Zip Code: 87117
 
Record
SN03117234-W 20130718/130716234754-7e4a23c6505762f0249f43ccb4001472 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.