MODIFICATION
K -- Demolish Heat Detectors
- Notice Date
- 7/19/2013
- Notice Type
- Modification/Amendment
- NAICS
- 561621
— Security Systems Services (except Locksmiths)
- Contracting Office
- Department of the Air Force, Air Force Special Operations Command, 27 SOCONS, 110 E. Sextant, Cannon AFB, New Mexico, 88103-5109, United States
- ZIP Code
- 88103-5109
- Solicitation Number
- FA4855-13-T-0007
- Archive Date
- 7/24/2013
- Point of Contact
- Benjamin L.Crain, Phone: 5757846065, Goldie Silvestre, Phone: 575-784-2956
- E-Mail Address
-
benjamin.crain@cannon.af.mil, goldie.silvestre@cannon.af.mil
(benjamin.crain@cannon.af.mil, goldie.silvestre@cannon.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Demolish Heat Detectors SOURCES SOUGHT ANNOUNCEMENT. The 27 Special Operations Contracting Squadron (27 SOCONS) is seeking information concerning the availability of capable contractors to provide non-personal services for the demolition of heat detectors. This Sources Sought is issued solely for information and planning purposes and does not constitute a solicitation nor is this notice a request for quotation or proposal. DO NOT submit a quote or proposal; no award will be made as a result of this sources sought. The Air Force will NOT be responsible for any cost incurred by interested parties in responding to this sources sought. ***PWS INFORMATION*** BASIC SERVICE: The contractor shall provide all labor, material, equipment, and supplies, necessary to provide demolition of heat detection components in Hangar 199. There are a total of 27 heat detectors to be demolished along with approximately 1000' of corresponding conduit and wiring while ensuring that the other fire components in the Hangar remain operational at Cannon AFB, NM. Before demolition begins a certified Fire Protection Engineer (FPE) shall perform tests on the wet pipe system to identify any discrepancies or anomolies. A. Hanger 199 is a 3 bay hanger with ceiling heights that vary from 19'-50'. There are a total 27 heat detectors installed within the 3 bays, 9 of which are located in a paint booth possibly requiring the use of respirators. The detectors, along with associated wiring and conduit, shall be removed in their entirety to the termination point in the mechanical room, leaving no remnants of the system behind. The work includes modifying existing and providing new water flow indicators for interior fire alarm system. Installation and testing must conform to the applicable requirements of NFPA 70, NFPA 72, and NFPA 90A. Equipment and devices shall be compatible and operable in all respects, and shall in no way impair reliability or operational functions of the existing interior fire alarm system and the existing base fire alarm system. Existing base fire alarm system is a radio system. Materials and equipment to be furnished under this contract shall be the current design products of manufacturers regularly engaged in production of such equipment and shall be listed by the Underwriters' Laboratories, Inc. in the UL Fire Prot Dir, or approved by Factory Mutual System and listed in FM P7825. B. Tests indicate that some of the heat detectors are wired in series with the pull stations, wet pipe system in the administrative offices, and with the high expansion foam (HEF) controls. A certified Fire Protection Engineer shall perform tests before demolition begins to check for any discrepancies or anomalies in the wet pipe system. The Contractor shall then provide an electrical schematic in the Demolition Plan (Red Lines on the GFI are acceptable) depicting how the heat detectors will be removed such that the above mentioned items will work properly once demolition is complete. The Demolition Plan shall include the Contractor's plan for ensuring the entire system will work (i.e. water flow valves or rewiring the pull stations). The contractor shall also provide redlined as-built plans or drawings in AutoCAD 2010 versions or later file showing where the termination of each of the utilities will stop. C. The Contractor shall ensure that, upon completion of removal of heat detection devices, the items mentioned in the sections A & B are in working condition. The Contractor shall be responsible for arranging preliminary and final testing to demonstrate the items wired in series with heat detection are in satisfactory working condition. ***END OF PWS INFORMATION*** If your firm is capable of providing the requirements described above, please provide a Statement of Capability to Ms. Dawn M. Armant (dawn.armant@cannon.af.mil), SSgt Benjamin Crain (benjamin.crain@cannon.af.mil), or SrA Goldie Silvestre (goldie.silvestre@cannon.af.mil) by July 23, 2012 @ 4:30PM MDT. The Statement of Capability shall include: A)Contractor Name •Address •Point of Contact (POC) •POC phone number(s) and email addresses •CAGE Code •Website, if applicable •State if your company is registered under NAICS Code 561621 or not •State your companies socio-economic status (business size and type) B)Description of Relevant Contract Experience (Government and Commercial) •Contract number •Description of the requirement •Dollar Value •POC for the requiring activity •POC address, email, phone number(s), fax number, and the company's web page, if applicable Any information provided by industry to the Government as a result of this sources sought synopsis is strictly voluntary. Responses will not be returned. No entitlements to payment of direct or indirect costs or charges to the Government will arise as a result of contractor submission of responses, or the Government's use of such information. The information obtained from industries responses to this notice may be used in the development of an acquisition strategy and future RFP.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFSOC/FA4855/FA4855-13-T-0007/listing.html)
- Place of Performance
- Address: 27 SOCONS, Cannon AFB, New Mexico, 88103, United States
- Zip Code: 88103
- Zip Code: 88103
- Record
- SN03121725-W 20130721/130719234312-7cddc9c66f0475387b5c886fc2aa5635 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |