SOLICITATION NOTICE
54 -- HazMat Storage Locker Without Explosion Panel
- Notice Date
- 9/3/2013
- Notice Type
- Combined Synopsis/Solicitation
- Contracting Office
- 1968 Gilbert St., Norfolk, VA 23511
- ZIP Code
- 23511
- Solicitation Number
- 1300365304
- Response Due
- 9/9/2013
- Archive Date
- 3/8/2014
- Point of Contact
- Name: Client Services, Title: Client Services, Phone: 1.877.933.3243, Fax: 703.422.7822
- E-Mail Address
-
Clientservices@fedbid.com;
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice.The solicitation number is 1300365304 and is issued as a Request for Quote (RFQ), unless otherwise indicated herein.The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2005-69. The associated North American Industrial Classification System (NAICS) code for this procurement is 332311 with a small business size standard of 500.00 employees.This requirement is a [ Small Business ] set-aside and only qualified offerors may submit quotes.The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2013-09-09 11:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com.FOB Destination shall be Norfolk, VA 23511 The FLC - Norfolk requires the following items, Meet or Exceed, to the following: LI 001: HAZMAT Storage Locker Without Explosion Panel. Item Description: - 22 ft locker/container. - Minimum Exterior Dimensions: 100Hx264Wx96D. - Minimum Interior Dimensions: 84.5Hx252Wx84D. - Minimum 55 Gallon Drum Capacity: 38. - Must have built-in spill containment sump with chemical resistant coating. Sump must be weather proof, noncombustible and minimum 12-gauge steel. Sump capacity must be minimum 25 percent of total storage capacity of the locker. - Minimum R-11 and Maximum R -15: Insulation in Walls & Ceiling. - Minimum: 12 Gauge Galvannealed Steel constructed for exterior walls. - Minimum: 20 Gauge cold roll interior walls. - Must be double wall construction with 3?-3.5? of air space throughout. - Underwrites Laboratories (UL) approved and 2008 & 2011 NEC compliance on all electrical installation. - Storage locker must be in accordance with standards set forth by National Fire Protection Association ( NFPA) Code 30 and comply with OSHA and EPA regulations. - Must be Factory Mutual (FM) approved for storing and dispensing of flammable and combustible liquids. - Locker base must have channel design to allow visual inspection under building. Crane/forklift opening to be provided for ease in off loading and relocation. - Minimum two air inlet vents in the front and two in the back of lock for nature ventilation. The Natural ventilation shall provide a rate of 1 cubic foot per min per square foot of floor space. Vents must have fire dampers and exterior louver for optimum airflow and preclusion of bird and animal entry. - All accessories must be FM & UL approved. - Color: Gray., 1, EA; LI 002: 50 Hz. Load Center. - One Contacter for AC. - One Contacter for exhaust system. - One 30 Amp Plug & Receptacle for AC Unit. - One 50 Hertz ? 30 Amp Plug & Receptacle for AC Unit., 1, EA; LI 003: - 19,500 British thermal unit (BTU) Hazardous Location AC Unit. - Class 1, Div. 2. - With Color Coded Thermostat. - Explosion Proof AC unit. 19,500 BTU. - 50 Hertz. - 230 V., 1, EA; LI 004: Explosion Proof Exhaust System. - 343 Cubic Feet of Air per Minute (CFM). - 50 Hertz., 1, EA; LI 005: 4-Hour Fire Rating. - Fire Rated Walls must be Intertek tested and FM approved for 4 Hours. - Fire Rated Roof must be Intertek tested and FM Approved for 3 Hours., 1, EA; LI 006: Explosion-Proof Interior Light w/Switch. -Incandescent., 2, EA; LI 007: -250 Volt Light Bulb. -Designed for 50 Hz Applications. -100 Watt., 2, EA; LI 008: Dry Chemical Fire Suppression System. - Fire Suppression System must be designed and installed in accordance with the National Fire Protection Association (NFPA17). The tank must be able to pressurize and the nitrogen cartridge is un-installed during shipping to prevent discharge and to in compliance Department of Transportation regulations., 1, EA; LI 009: Dry Chemical Fire Suppression System Audible Alarm. - 50 Hz. - 240 Volt. -.07 Amp. Color: Red., 1, EA; LI 010: - 60'W x 80'H Double Door 4-Hour Fire Rated. - Must have UL classified commercial grade keyed lock set. - The double door should have one active leaf to serve as personnel entrance and exit. It must be equipped with a door closer., 2, EA; LI 011: SHELVES, 14"W with 2" LIP SIDES. - Minimum 3/10? tiers on the back wall. - Maximum 3/17' tiers on the back wall. - Minimum of 30 feet. - Maximum of 51 feet., 20, EA; LI 012: Grounding Kit (8ft rod, 10ft cable & clamp)., 1, EA; LI 013: Fiberglass Floor Grating., 1, EA; LI 014: Portable Eyewash Station 16 gallon capacity. -Green., 1, EA; LI 015: 2.5 lb. Refillable Portable Fire Extinguisher. - ABC Dry Chemical., 1, EA; LI 016: 24"W x 72"L Steel Ramp w/Skid-Resistant Finish., 1, EA; LI 017: - U.S. Department of Transportation Hazardous Placard Holder. - Front of the locker., 2, EA; LI 018: - National Fire Protection Association 704 rating signs. - Front of locker., 2, EA; LI 019: ***QUOTE SHALL INCLUDE SHIPING TO NORFOLK, VA., 1, EA; Solicitation and Buy Attachments ***Question Submission: Interested offerors must submit any questions concerning the solicitation at the earliest time possible to enable the Buyer to respond. Questions must be submitted by using the 'Submit a Question' feature at www.fedbid.com. Questions not received within a reasonable time prior to close of the solicitation may not be considered.*** For this solicitation, FLC - Norfolk intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. An Offeror may submit a series of pricing quotes, which descend in price during the specified period of time for the aforementioned reverse auction. FLC - Norfolk is taking this action in an effort to improve both vendor access and awareness of requests and the agency's ability to gather multiple, competed, real-time quotes.All responsible Offerors that respond to this solicitation MUST submit the pricing portion of their quote using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a quote on www.FedBid.com.Offerors that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Offerors that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Offerors may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith quotes, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process.Should offerors require additional clarification, notify the point of contact or FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com.Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Failure to comply with the below terms and conditions may result in offer being determined as non-responsive. This announcement constitutes the only solicitation; a formal, written solicitation will not be issued. PAPER COPIES OF THIS SOLICITATION WILL NOT BE AVAILABLE. This solicitation documents and incorporates provisions and clauses in effect through FAC 2005-60 and DFARS Change Notice 20120724. It is the responsibility of the contractor to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at these addresses: www.acqnet.gov/far and http://www.acq.osd.mil/dpap/dfars/index.htm The NAICS code is 332311 and the Small Business Standard is 500. FAR 52.247-34, F.o.b. Destination applies New Equipment ONLY; NO remanufactured or "gray market" items. All items must be covered by the manufacturer's warranty. No partial shipments are permitted unless specifically authorized at the time of award. Bid MUST be good for 30 calendar days after close of Buy. FAR 52.212-3 Offeror Reps and Certs / FAR 52.212-3 Alt1 Offeror Reps and Certs. EFFECTIVE JAN 2005, all offerors are required to use ?Online Representations and Certifications Application (ORCA) to respond to federal solicitations. To register in ORCA, please go to www.bpn.gov/orca. You must be active in the Central Contractor Registration (www.ccr.gov) and have a Marketing Partner Identification Number (MPIN), to register in ORCA. Failure to register in ORCA may preclude an award being made to your company. The full text of the referenced FAR clauses may be accessed electronically at https://www.acquisition.gov/Far/ 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders?Commercial Items. 52.204-10 Reporting Subcontract Awards. 52.219-28 Post-Award Small Business Program Rerepresentation. 52.222-3 Convict Labor 52.222-19 Child Labor--Cooperation with Authorities and Remedies 52.222-21 Prohibition of Segregated Facilities 52.222-26 Equal Opportunity 52.222-36 Affirmative Action for Workers w/ Disabilities 52.223-18 Contractor Policy to Ban Text Messaging while Driving (SEPT 2010) 52.225-13 Restrictions on Certain Foreign Purchases. 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items. (MAR 2011) 252.247-7023 (iv) Alt III - ALTERNATE III (MAY 2002) 252.247-7023. 252.232-7010: Levies on Contract Payments 5252.NS-046P: Prospective Contractor Responsibility 52.212-4: Contract Terms and Conditions-Commercial Items 52.212-1: Instructions to Offerors-Commercial Items 52.252-1:Solicitation Provisions Incorporated by Reference 52.252-2: Clauses Incorporated by Reference Control of Government Personnel Work Product (April 1992) 252.203-7000: Requirements Relating to Compensation of Former DOD Officials (Sep 2011) 252.203-7005 Representation Relating to Compensation of Former DOD Officials (Nov 2011) 52.204-7 Central Contractor Registration (Dec 2012) 52.204-13 CCR Maintenance (Dec 2012) 52.209-6 Protecting the Government's Interest When Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment (Dec 2010) 52.219-6 Notice of Total Small Business Set-Aside (Nov 2011) 52.232-33 Payment by Electronic Funds Transfer - CCR (Oct 2003) 52.225-25 Prohibition on Contracting with Entities Engaging in Certain Activities or Transactions Relating to Iran -- Reps and Certs (Dec 2012) 252.204-7004 Alt A Central Contractor Registration (Feb 2013) 252.223-7008 Prohibition of Hexavalent Chromium (May 2011)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVSUP/N00189/1300365304/listing.html)
- Place of Performance
- Address: Norfolk, VA 23511
- Zip Code: 23511
- Zip Code: 23511
- Record
- SN03172145-W 20130905/130903235832-3e5d2215c58eef3f6c885998a08611fa (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |