SOLICITATION NOTICE
10 -- Construction and installing of lightning protection system
- Notice Date
- 9/17/2013
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238290
— Other Building Equipment Contractors
- Contracting Office
- RCO Grafenwoehr (PARC Europe, 409th CSB), UNIT 28130, APO, AE 09114
- ZIP Code
- 09114
- Solicitation Number
- W912PB13T8044
- Response Due
- 9/26/2013
- Archive Date
- 11/16/2013
- Point of Contact
- Phuong Nguyen, 09641838873
- E-Mail Address
-
RCO Grafenwoehr (PARC Europe, 409th CSB)
(phuong.h.nguyen3.mil@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. 1.1. Construct two (2) Lightning protection systems at Tugay Komutanligi Gaziantep, Turkey 1.2. Tugay Komutanligi Gaziantep currently has no lightning protection and was not designed to be a critical storage facility requiring such protection. A lightning protection system must be designed and implemented consisting of a conductor system with air terminals on the roof of the building; bonding of the structure and other metal objects; grounding of electrodes, and interconnecting conductors. 1.3. Objectives. Tugay Komutanligi Gaziantep requires a safe, secure, and fully supported facility to sustain its critical site description. The facility and its electrical infrastructure must be protected from lightning strikes. Properly designed / constructed lightning protection systems do work and pass the current to ground, preventing damage from electrocution, human burns, burning buildings, exploding bricks and mortar, melted electrical equipment, damaged electronic equipment and stresses on electronic equipment which can fail before their normal mean time before failure Work will be done at Tugay Komutanligi Gaziantep, Turkey. The contractor shall construct two (2) lighting protection systems in accordance with the specifications and guidelines in DoD Manual 6055.09-M, Vol. 2, February 29, 2008; Incorporating Change 1, April 6, 2012, DoD Ammunition and Explosives Safety Standards: Explosives Safety Construction Criteria and NFPA 780 2011 edition. The attached design are for site specific dimensions and general configurations, any conflict between design and specifications in DoD Manual 6055.09-M and NFPA 780 will be brought to the attention of the contracting office before submitting quotes. DoD Manual 6055.09-M and NFPA 780 specifications will have priority over specifications in the design. The contractor shall provide their own detailed drawings for approval by the contracting officer. References in the drawings to MIL-HDBK-1004/6 30 May 1988 will be omitted. The contractor can final drawing shall include steel mast mounted on concrete foundations. Concrete masts or use of steel masts without concrete foundations, if within the design specifications in NFPA 780, can be considered.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/b4fb576d1ec60a58ac403a0c2c7118c1)
- Place of Performance
- Address: RCO Grafenwoehr (PARC Europe, 409th CSB) UNIT 28130, APO AE
- Zip Code: 09114
- Zip Code: 09114
- Record
- SN03191020-W 20130919/130917235527-b4fb576d1ec60a58ac403a0c2c7118c1 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |