SOLICITATION NOTICE
S -- Consolidated Electrical Services
- Notice Date
- 9/19/2013
- Notice Type
- Presolicitation
- NAICS
- 221118
— Other Electric Power Generation
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, AFLCMC/PZIO - WPAFB, 1940 ALLBROOK DRIVE, WRIGHT-PATTERSON AFB, Ohio, 45433-5309, United States
- ZIP Code
- 45433-5309
- Solicitation Number
- FA8601-13-R-0073
- Archive Date
- 10/18/2013
- Point of Contact
- Zachary Kauth,
- E-Mail Address
-
zachary.kauth.1@us.af.mil
(zachary.kauth.1@us.af.mil)
- Small Business Set-Aside
- N/A
- Description
- THIS IS NOT A REQUEST FOR A QUOTE, PROPOSAL OR ANY OFFER WHATSOEVER. The Government is in no way obligated to do business with or to enter into any form of agreement or contractual relationship with any person, company or other entity that sees this announcement, submits inquiries, provides information regarding capabilities or otherwise responds to this announcement. Information provided in response to this announcement by any means whatsoever and in any form whatsoever shall be at the expense of the provider. The Government will not compensate any person, company or other entity that submits any information in response to this announcement. ALL INQUIRIES AND/OR RESPONSES ARE DUE NO LATER THAN NOON, LOCAL TIME, ON 3 OCTOBER 2013. This announcement is part of continuous market research to assess whether there are businesses capable of providing electrical generation, transmission, and distribution to Wright-Patterson Air Force Base (WPAFB), Ohio AS A CONSOLIDATED PRODUCT. Under this approach, a single source would provide generation, distribution, and transmission of electricity to WPAFB under one contract. This announcement allows businesses in the industry and other interested parties to provide feedback, which will help improve WPAFB's understanding of the industry and its ability to satisfy this requirement. WPAFB is particularly interested in the availability and potential size of discounts and savings that may result from the acquisition of electrical generation, transmission, and distribution AS A CONSOLIDATED PRODUCT. Currently the peak demand at WPAFB is 77.5 MW(mega-Watts as of 4 Jul 2013 with a consumption of 41,910,011 kWh (kilo-Watt-hours from 30 Jun - 31 Jul). WPAFB anticipates a load increase over the next year at 8.5 MW of demand and 6,000,000 kWh of consumption. Attached to this announcement are the technical requirements for WPAFB. Careful compliance with these requirements is required. CAPABILITIES STATEMENTS: Prospective sources must be certified by the Public Utilities Commission of Ohio (PUCO) and show proof of that certification and must demonstrate their capability to provide the required consolidated product. Capabilities statements shall include projections of discounts on current and future loads and sufficient information to determine if the firm can meet the minimum technical requirements. A completed Offeror Representations and Certifications IAW FAR 52.212-3 (ALT I) shall be submitted. Responses shall include company name, physical and mailing address, and point of contact with his/her phone number. Prospective sources must also indicate their business size status base (e.g. large, small, 8(a), woman-owned, HUBZone, service-disabled veteran-owned small business, etc.) in relation to North American Industry Classification System (NAICS) code 221119. Prospective Sources should also include their corresponding Dun & Bradsheet Number (DUNS Number) and Commercial and Government Entity (CAGE) Codes. Questions or capabilities statements can be sent via fax, e-mail, U.S. Postal Service or commercial carrier to the attention of Zachary Kauth referencing announcement number FA8601-13-R-0073. Send faxes to 937-257-3926 or 937-656-1412. Send e-mail to zachary.kauth.1@us.af.mil. You are advised that all correspondence sent via e-mail shall contain a subject line that reads "FA8601-13-R-0073, Consolidated Electric Service." Note that e-mail filters at Wright-Patterson are designed to filter e-mails without subject lines or with suspicious subject lines or contents (i.e.,.exe or.zip files). Therefore, if this subject line is not included, the e-mail may not get through the e-mail filters. Also be advised that.zip or.exe files are not allowable attachments and may be deleted by the e-mail filters at WPAFB. If documents are attached to an e-mail, ensure only.pdf,.doc,.docx,.xls. or.xlsx documents are sent. The e-mail filters may delete any other form of attachments. Documents sent via the U.S. Postal Service or commercial carrier should be addressed to: AFLCMC/PZIOB ATTN: Zachary Kauth 1940 Allbrook Drive, Room 109 WPAFB OH 45433-5344 You can contact Zachary Kauth by telephone at 937-522-4611. ALL INQUIRIES AND/OR RESPONSES ARE DUE NO LATER THAN NOON, LOCAL TIME, ON 3 OCTOBER 2013. TECHNICAL REQUIREMENTS: The contractor shall furnish all labor, tools, material, equipment, and incidentals to supply and delivery firm electric power. The delivery point for such power shall be that point on the electrical system at which the Dayton Power and Light Company takes possession of the electricity for final delivery of the electricity to the meter(s) of the specific facilities on Wright-Patterson Air Force Base in Ohio. Contractor will provide deregulated electric generation service to accommodate an estimated annual volume of 415,000,000 kWh (calendar year) of firm electrical generation to the point of delivery to the supplying electrical grid. Due to an addition of buildings in the coming year, Wright-Patterson anticipates an average annual increase in electrical consumption from 2009 to 2010 of 5 percent. The contractor will be responsible for providing and coordinating all services required to delivery firm electrical generation services to the designated point of service. Electrical generation service shall be available and commence on 1 January 2014. The resulting contract will be a firm-fixed price and shall have a performance period of a minimum of one-year and a maximum of five years duration. EVIDENCE OF RESPONSIBILITY: An offeror must possess, at a minimum, twelve consecutive months of experience (within the past two years) providing firm generation of electricity to wholesale or retail customers. Respondent shall provide evidence that it is authorized to conduct business by each state's regulatory body having jurisdiction over the state's electric industry prior to award of any contract for solicited requirements. The offeror must demonstrate the ability to obtain, transmission service agreements in the company's name for the ability to obtain necessary transmission service agreements shall render the respondent non-responsible. CAPABILITIES STATEMENT: Interested parties shall submit a capabilities package, with a cover letter, that is brief and concise, yet clearly demonstrates ability to meet the stated requirements with sufficiently qualified personnel. The capabilities package should clearly present evidence that the interested party is fully capable of providing the required electric generation services and as such may contain any information that the interested party feels is relevant. The following issues should be also addressed in the capabilities package: 1. Provide a description as to your capability and capacity to perform and manage the work; 2. Address briefly how your company will perform this work; a. Clearly describe your background and experience, within the past ten years, in providing labor, tools, material, equipment, and incidentals to supply and deliver firm electrical power to the point of service; b. Identify the proposed sources of supply for base load generation; c. Describe whether electricity would be provided from a generation owned by the offeror, obtained under long-term contracts, and/or obtained under short-term contracts/spot market purchases; d. Indicate whether the sources of supply are located within the service control area, or an adjacent control area; e. Describe how electricity would be transmitted from the sources of supply identified above to Wright-Patterson Air Force Base, Ohio.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/88 CONS/FA8601-13-R-0073/listing.html)
- Place of Performance
- Address: Wright-Patterson AFB, OH, WPAFB, Ohio, 45433, United States
- Zip Code: 45433
- Zip Code: 45433
- Record
- SN03195967-W 20130921/130920000356-bb0e150c8997ebfddf597f7911de1e27 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |