AWARD
Y -- Relocate Lab to Bldg 761 and Install Cleanroom in Building 760, Kirtland Air Force Base, Bernalillo County, New Mexico
- Notice Date
- 9/20/2013
- Notice Type
- Award Notice
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- USACE District, Albuquerque, CESPA-CT, 4101 Jefferson Plaza NE, Albuquerque, NM 87109-3435
- ZIP Code
- 87109-3435
- Solicitation Number
- W912PP-13-P-0123
- Archive Date
- 10/20/2013
- Point of Contact
- Karen Irving, (505) 342-3356
- E-Mail Address
-
USACE District, Albuquerque
(karen.k.irving@usace.army.mil)
- Small Business Set-Aside
- N/A
- Award Number
- W912PP-13-P-0123
- Award Date
- 9/17/2013
- Awardee
- ALMS, Limited Company (620117833) <br> 11 Espejo Ave <br> Moriarty, NM 87035-5338
- Award Amount
- $143,697.08
- Line Number
- 0001
- Description
- This contract action was accomplished using other than competitive procedures because a statute exists that expressly authorizes or requires that the acquisition be made from a specific source or through another agency (FAR 6.302-5); specifically, Sole source awards under the 8(a) Program. Per FAR 6.302-5 a J&A is not required for this award. Relocate and Prep Lab and Assemble Cleanroom Relocate all identified lab equipment from Bldg. 422, Lab 110, to Bldg. 761, Lab 7. Bldg. 761 Lab 7 Preparation - Install window coverings as specified on both windows in Lab 7. Install laser interlock system as specified at both doors into Lab 7. Provide new covers for floor electrical boxes. Bldg. 760 Lab 115 Cleanroom Installation - Remove existing optic tables. Protect and store in Hanger. Purchase and install cleanroom as specified in Lab 115. Install laser interlock system at hangar door and mechanical room door into Lab 115. Provide the following power receptacles in main lab area: a. Ten (10) each 250v-30A with 15' long whips. b. Six (6) each 250v-30A with 15' long whips. c. Nine (9) each 120v-20A quad boxes on 16' long whips. e. Two (2) quad 120v outlets in the mezzanine area. Customer to provide specific location. f. Refer to attached drawing for lab electrical locations. g. Return optic tables to Lab 115. h. Install 4'x7' concrete equipment pad for Chiller outside of lab 115.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA47/Awards/W912PP-13-P-0123.html)
- Record
- SN03197753-W 20130922/130921000045-9fdea01a45f78df0131b03bcae596ddd (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |