Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 25, 2013 FBO #4323
SOURCES SOUGHT

Z -- CAP 076086 - Installation of Lightning Protection Systems (MOTCO) Concord, CA

Notice Date
9/23/2013
 
Notice Type
Sources Sought
 
NAICS
238290 — Other Building Equipment Contractors
 
Contracting Office
USACE District, Sacramento, 1325 J. Street, Sacramento, CA 95814
 
ZIP Code
95814
 
Solicitation Number
W91238-13-S-0266
 
Response Due
10/14/2013
 
Archive Date
11/22/2013
 
Point of Contact
Ryan Bayless, 916-557-7090
 
E-Mail Address
USACE District, Sacramento
(ryan.j.bayless@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a SOURCES SOUGHT SYNOPSIS. This announcement seeks information from industry, which will be used for preliminary planning purposes. No proposals are being requested or accepted with this synopsis. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. NO SOLICITATION, SPECIFICATIONS, OR DRAWINGS ARE AVAILABLE AT THIS TIME. Responses are being sought from qualified small and large business concerns possessing the technical/construction expertise and bonding capability to execute the work requirements. The required work elements include, but may not be limited to the following; installation of poles, catenary lightning protection systems (with ground loops), and exterior security lighting. Work performance may require multiple mobilizations in order to accommodate an on-going mission schedule, which will prohibit construction/occupation all non-essential personnel from occupying the tidal side of the installation during a mission. Interested contractors must be able to provide verifiable experience of performing similar projects that involve both electrical and civil disciplines working within areas having existing fill (bay mud). Description of Work: The installation (previously known as the Concord Naval Weapons Station) is now known as Military Ocean Terminal Concord (MOTCO), which the Department of the Army has taken possession from the Department of the Navy several years ago. The current areas that require Lightning Protection Systems were originally constructed (for the Department of Navy missions) without existing protection from lightning strikes. The current customer desires the installation of Lightning Protection Systems that are to cover the following 4 locations; Classification Yards 1 & 2, Building 177, and the quote mark R quote mark Buildings (#'s 1 through 4). These locations are separated from one another and are located on the Tidal Side of the Installation where there is the potential for uncovering Unexploded Ordnance. This situation will require special circumstances during the construction effort, which will include the employment of UXO Construction Support during all construction activities. The basic approach to the construction of the MOTCO Lightning Protection project will be to erect steel poles with construction of overhead catenaries except at R1-R4 building site where both steel and wood poles are utilized without catenary but with air terminals. The lightning poles should be supported by 28 foot deep (3 feet diameter drilled) cast-in-place caisson foundations at all locations with the exception of the quote mark R quote mark Buildings location, where it is anticipated that four 16 inch square concrete precast piles will be driven 78 feet deep and a pile cap to be formed and poured after pile driving operations.. It is anticipated that Building 177 will require a total of 15 new steel lightning poles, twenty new steel lightning poles for Classification Yard #1, twenty new steel lightning poles for Classification Yard #2, and 8 new steel poles & six new wood poles for the quote mark R quote mark Buildings. The lightning poles are required to be electrically grounded (via 2 copper clad grounding rods) with the stringing overhead catenaries for 3 sites but without stringing overhead catenary for R1-R4 building site. Trenching for the installation of an underground bare copper counterpoise, and exothermic welding ( which will be required at each lightning pole location) will be part of Contractor's responsibility.. The purpose of this synopsis is to gain knowledge of interest, capabilities and qualifications of various members of industry, Large and Small Business Communities. The Government must ensure there is adequate competition among the potential pool of responsible contractors. This procurement is for: 1. Construction 2. Estimated construction range: $1 - $5 Million 3. NAICS Code: 238290 4. Business Size Standard: To be determined after responses to the sources sought are received and evaluated. 5. FSC Code: Z2QA 6. In accordance with FAR 52.219-14(b)(3), Limitation on Sub-Contracting: quote mark General Construction. quote mark The concern will perform at least 15 percent of the cost of the contract, not including the cost of materials quote mark. Prior Government contract work is not required for submitting a response under this sources sought synopsis. The official Synopsis citing the solicitation number will be issued on Federal Business Opportunities www.fbo.gov and inviting firms to register electronically to receive a copy of the solicitation when it is issued. A firm-fixed price contract is anticipated to be awarded using sealed bidding criteria. Firm's response to this Synopsis shall be limited to 10 pages and shall include the following information: Firm's name, address, point of contact, phone number, and e-mail address. Firm's interest in bidding on the solicitation when it is issued. Provide Example Projects: The firm should provide a brief description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of the project - Provide at least one (1) example project demonstrating lightning protection experience and two (2) example projects demonstrating experience in trenching within environmentally sensitive habitat areas and the use of UXO Construction Support. Firm's Business Size category (Large Business, Small Business, HUB Zone, Service Disabled Veteran Owned Small Business, Women Owned, or 8(a). Firm's Joint Venture information if applicable - existing and potential Proof of available bonding capacity in the amount of at least 5,100,000.00. Documentation must be in the form of a statement from the contractor's bonding company via letter from bonding company Responses must be printed on 8.5X11 paper, front only, and limited to no more than 10 pages. Facsimile responses will not be accepted. Interested Firm's shall respond to this Sources Sought Synopsis no later than 1:00 pm, Monday, 14 October 2014. All interested firms must be registered in CCR to be eligible for award of Government contracts. Email responses to: Ryan.j.bayless@usace.army.mil, or Carol.a.dones@usace.army.mil mail responses to: USACE Sacramento District, Attn: Ryan Bayless, 1325 J Street, Rm. 878, Sacramento, CA 95814 EMAIL IS THE PREFERRED METHOD WHEN RECEIVING RESPONSES TO THIS SYNOPSIS.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA05/W91238-13-S-0266/listing.html)
 
Place of Performance
Address: USACE District, Sacramento 1325 J. Street, Sacramento CA
Zip Code: 95814
 
Record
SN03198234-W 20130925/130923234908-2bdaf6775fcda7a1a41116376e91e4e6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.