MODIFICATION
61 -- UPS batteries and installation for Ft. Huachuca, AZ.
- Notice Date
- 9/24/2013
- Notice Type
- Modification/Amendment
- NAICS
- 335912
— Primary Battery Manufacturing
- Contracting Office
- ACC-APG - Southwest, ATTN: AMSEL-AC-CC-S, Building 61801, Room 3212, Fort Huachuca, AZ 85613-6000
- ZIP Code
- 85613-6000
- Solicitation Number
- W9128Z13T0018
- Response Due
- 9/26/2013
- Archive Date
- 11/23/2013
- Point of Contact
- Eva McElroy, 52053872472
- E-Mail Address
-
ACC-APG - Southwest
(eva.mcelroy@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- There are questions from vendors answered by the government attached. SF 1449 is also attached. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. 1.This requirement will be awarded as a Firm Fixed-Price contract on an all or none basis, to the lowest priced offer that meets all the terms and conditions of the solicitation. This is for UPS batteries and installation. Please see below for salient features. Brand name or equal. 2. The contracting officer will evaluate equal products on the basis of information furnished by the offeror identified in the offer and reasonably available to the contracting officer. The contracting officer is not responsible for locating or obtaining any information not identified in the offer. 3.Government RFQ SF1449 format must be used for quote submission. If not used, your submission will be considered nonresponsive. Please fill in Blocks 17a, 30a, 30b, 30c, and fill in all pricing and all applicable taxes on all contract line items (CLIN's). Please total all CLINs, in your quote to show an overall final price and include all shipping charges FOB destination lead time. Also include any and all reinstatement fees if applicable. Scan and email the offer to eva.t.mcelroy.civ@mail.mil. Non-compliance may result in rejection of your offer. 4.Complete the following clause: FAR clause 52.212-3 Offeror Representations and Certifications Commercial items. (This clause does not have to be completed if you are ORCA registered, at (https://orca.bpn.gov/)). 5.Your quote shall be submitted via e-mail no later than 11:00 AM AZ MST, on 25 September 2013. It shall be addressed to Ms. Inna I. Lloyd, contracting officer email: inna.i.lloyd.civ@mail.mil and Ms. Eva T. McElroy, Contract Specialist email: Eva.t.mcelroy.civ@mail.mil. If you have any questions, please contact Ms. Eva T. McElroy at (520) 538-7472 or Ms. Inna I. Lloyd at (520) 538-2923. 6. Shipping information: All items must be received at the following address on or before the stated delivery date. Please disregard the shipping information in the CLINs and use the below shipping information: USAISEC - PBO Warehouse 80811 Arizona Street Ft. Huachuca, AZ 85613 7.Special instructions: a. Any products offered must be in compliance with required salient features. b. Any products offered must not void warranties on existing government-owned equipment. Items offered must be compatible with the manufacturers full performance warranty, and provide a fully certified end-to-end solution. If applicable, submit a list of warranty information to include type and length of warranty. c. The salient features are on the attached documents. d. If a delivery date of 22 October 2013 is not reasonable, please inform the government of what a reasonable date is. UPS Batteries CLIN 0001 lCMET II (53302), Room 123 UPS Powerware 9393, System 9390-80, Model 80, KVA 80 40Batteries total. Salient features - Brand name or equal. Cells per unit 6 Voltage per unit 12 Capacity 330W @ 15-minute rate to 1.67V per cell @ 77 F (25 C) Maximum 800A (5 sec) discharge current Internal resistance 4 m Operating temperature range: Discharge: 5 F~122 F (-15 C~50 C), Charge: 5 F~104 F (-15 C~40 C), and Storage: 5 F~104 F (-15 C~40 C) Nominal operating temperature range needs to be around 77 F 5 F (25 C 3 C) Float charging voltage 13.5 to 13.8 Vdc/unit Maximum charging current limit 33A Equalization and cycle service 14.4 to 15.0 Vdc/unit Terminal 12-thread lead alloy recessed terminal to accept M6 bolt Five year warranty preferred CLIN 0002 TIC (Bldg 53302), Outside UPS UPS Powerware 9315, System 9315-500, Model 500, KVA 500 120 batteries total. Salient features: Brand name or equal. Cells per unit 6 Voltage per unit 12 Capacity 390W @ 15-minute rate to 1.67V per cell @ 77 F (25 C) Maximum 800A (5 sec) discharge current Internal resistance 4 m Operating temperature range: Discharge: 5 F~122 F (-15 C~50 C), Charge: 5 F~104 F (-15 C~40 C), and Storage: 5 F~104 F (-15 C~40 C) Nominal operating temperature range needs to be around 77 F 5 F (25 C 3 C) Float charging voltage 13.5 to 13.8 Vdc/unit Maximum charging current limit 39A Equalization and cycle service 14.4 to 15.0 Vdc/unit Terminal 12-thread lead alloy recessed terminal to accept M6 bolt Five year warranty preferred. CLIN 0003 CMET-1 (Bldg 53301), Outside UPS Mitsubishi 9800A Series, Type UP9833A, KVA 300 80 batteries total Salient features: Brand name or equal. Voltage per unit 12 volt, 119 AH Capacity 506W @ 15-minute rate to 1.67V per cell @ 77 F (25 C) Maximum 913A (2 min rate) discharge current Internal resistance 2.8 m Nominal operating temperature range needs to be around -4 F (-20 C) to 122 F (50 C) Float charging voltage 2.25 - 2.28 Volts per cell at 77 F (25 C) Terminal: M6 Threaded Receptacle Short Circuit Discharge: 4510 Nominal Ah: 8 hr rate @ 15 min. Overall * Typical Max Internal Five year warranty preferred.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/2d562620cfe87b9aeba7ae2fe90fef0e)
- Place of Performance
- Address: ACC-APG - Southwest ATTN: AMSEL-AC-CC, Building 61801, Room 3212 Fort Huachuca AZ
- Zip Code: 85613-6000
- Zip Code: 85613-6000
- Record
- SN03200165-W 20130926/130924234752-2d562620cfe87b9aeba7ae2fe90fef0e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |