Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF SEPTEMBER 27, 2013 FBO #4325
SOLICITATION NOTICE

J -- Fire Suppression System Repairs - Attachment 1: Wage Determination - Solicitation - Attachment 2: Statement of Work

Notice Date
9/25/2013
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of the Air Force, Air Combat Command, 4 CONS, 1600 Wright Brothers Ave, Bldg 3010, Seymour Johnson AFB, North Carolina, 27531, United States
 
ZIP Code
27531
 
Solicitation Number
FA4809-13-T-0047
 
Archive Date
10/12/2013
 
Point of Contact
Garrett I. Silva, Phone: 9197225423
 
E-Mail Address
garrett.silva@us.af.mil
(garrett.silva@us.af.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Attachment 2: Statement of Work Solicitation Attachment 1: Wage Determination The 4th Contracting Squadron, USAF, Seymour Johnson Air Force Base, NC is currently soliciting quotes for the following Item(s)/Service(s): CLIN 0001 - Building 4535 -Repair Uni-Flange leak at the very base of the 6" fire suppression system at the point of entry from the lead-in to the sprinkler riser. Please see the attached Statement of Work (SOW) for more information on specific requirements. CLIN 0002 - Building 4535 - Purchase and installation of a new hydraulic actuator valve on the existing 2" stainless steel foam concentrate line to proportioner. Valve is to be electronically operated and normally closed. Contractor is to perform necessary wiring from valve to the existing fire alarm control panel. Please see the attached Statement of Work (SOW) for more information on specific requirements. CLIN 0003 - Building 4538 - Purchase and installation of two (2) new hydraulic actuator valves on the existing 2" stainless steel foam concentrate lines to proportioner. Valves are to be electronically operated and normally closed. Contractor is to perform necessary wiring from valves to the existing fire alarm control panel. Please see the attached Statement of Work (SOW) for more information on specific requirements. CLIN 0004 - Building 5015 -Replace all internal components of the fire pump using manufacture specific rebuild kit. Pump info: Patterson, Vertical Shaft, Serial# FP-C043782, 500 GPM, 3570 RPM.) (Motor Info: US Motor, 30HP,3530RPM,Electric,208 Volts,30 Amps, 3 Phase.) Please see the attached Statement of Work (SOW) for more information on specific requirements. For further information on specific requirements regarding this procurement please review the attached solicitation documents. Please email garrett.silva@us.af.mil for any questions regarding this solicitation.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/ACC/4CONS/FA4809-13-T-0047/listing.html)
 
Place of Performance
Address: Seymour Johnson Air Force Base, NC, Goldsboro, North Carolina, 27531, United States
Zip Code: 27531
 
Record
SN03202574-W 20130927/130925235735-271892a70bed9cd81ae44cf08082aeff (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |