SOLICITATION NOTICE
J -- Fire Suppression System Repairs - Attachment 1: Wage Determination - Solicitation - Attachment 2: Statement of Work
- Notice Date
- 9/25/2013
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of the Air Force, Air Combat Command, 4 CONS, 1600 Wright Brothers Ave, Bldg 3010, Seymour Johnson AFB, North Carolina, 27531, United States
- ZIP Code
- 27531
- Solicitation Number
- FA4809-13-T-0047
- Archive Date
- 10/12/2013
- Point of Contact
- Garrett I. Silva, Phone: 9197225423
- E-Mail Address
-
garrett.silva@us.af.mil
(garrett.silva@us.af.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- Attachment 2: Statement of Work Solicitation Attachment 1: Wage Determination The 4th Contracting Squadron, USAF, Seymour Johnson Air Force Base, NC is currently soliciting quotes for the following Item(s)/Service(s): CLIN 0001 - Building 4535 -Repair Uni-Flange leak at the very base of the 6" fire suppression system at the point of entry from the lead-in to the sprinkler riser. Please see the attached Statement of Work (SOW) for more information on specific requirements. CLIN 0002 - Building 4535 - Purchase and installation of a new hydraulic actuator valve on the existing 2" stainless steel foam concentrate line to proportioner. Valve is to be electronically operated and normally closed. Contractor is to perform necessary wiring from valve to the existing fire alarm control panel. Please see the attached Statement of Work (SOW) for more information on specific requirements. CLIN 0003 - Building 4538 - Purchase and installation of two (2) new hydraulic actuator valves on the existing 2" stainless steel foam concentrate lines to proportioner. Valves are to be electronically operated and normally closed. Contractor is to perform necessary wiring from valves to the existing fire alarm control panel. Please see the attached Statement of Work (SOW) for more information on specific requirements. CLIN 0004 - Building 5015 -Replace all internal components of the fire pump using manufacture specific rebuild kit. Pump info: Patterson, Vertical Shaft, Serial# FP-C043782, 500 GPM, 3570 RPM.) (Motor Info: US Motor, 30HP,3530RPM,Electric,208 Volts,30 Amps, 3 Phase.) Please see the attached Statement of Work (SOW) for more information on specific requirements. For further information on specific requirements regarding this procurement please review the attached solicitation documents. Please email garrett.silva@us.af.mil for any questions regarding this solicitation.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/ACC/4CONS/FA4809-13-T-0047/listing.html)
- Place of Performance
- Address: Seymour Johnson Air Force Base, NC, Goldsboro, North Carolina, 27531, United States
- Zip Code: 27531
- Zip Code: 27531
- Record
- SN03202574-W 20130927/130925235735-271892a70bed9cd81ae44cf08082aeff (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |