Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 20, 2013 FBO #4348
DOCUMENT

Y -- Project Number 568-001, Surgical Tower Addition - Attachment

Notice Date
10/18/2013
 
Notice Type
Attachment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of Veterans Affairs;VISN 23, Purchase and Contract Section;4101 Woolworth Avenue, Bldg C;Omaha NE 68105
 
ZIP Code
68105
 
Solicitation Number
VA26314R0103
 
Response Due
10/28/2013
 
Archive Date
11/12/2013
 
Point of Contact
VA Nebraska-Western Iowa HCS
 
E-Mail Address
oolworth
 
Small Business Set-Aside
Total Small Business
 
Description
The Department of Veterans Affairs, NCO 23, Nebraska-Western Iowa Health Care System Construction Product Line Team will be soliciting a construction project for the Fort Meade VA in South Dakota that shall include, but not be limited to, furnishing all labor, materials, transportation and supervision necessary to complete the project description included here. The Project includes an approximate 36,000 SF multi-story addition to the north side of the Building 113; which will house the relocated Surgical Suite, Post Anesthesia Care Unit (PACU), and Support Facilities on the Second Floor and Mechanical Equipment will be on the first story and Penthouse of the addition. The Site is an open area on the north side of the Hospital; but will require relocation of the perimeter road, relocation of utilities and new utilities. Renovations will include connections at Basement, 1st, and 2nd Floors; along with a mechanical penthouse. The estimated construction cost is between $5M and $10M. Deductive Bid Alternates are included. Site work generally includes new storm and sanitary sewer connections; as well as electrical service for both normal and emergency. The site work also includes construction of a new roadway to replace the existing in the vicinity of the Project, grading, retaining wall, walks, stairs, parking area, new site lighting, and paved drives. Demolition work on the site will generally include removal of site improvements, trees/landscaping, roadways, utilities, and necessary excavation for the new structure. Building demolition work will include removal of portions of the existing exterior walls, interior construction, mechanical/electrical construction, concrete floor slabs, and saw cutting concrete openings. Salvage of certain identified building elements is identified. The building addition Structure is structural steel beam system with a structural load bearing CMU exterior walls and a slab-on-grade, concrete foundations. The Addition generally includes face brick, insulated metal panels, aluminum-glass curtainwall, and architectural louvers with metal trims, metal stud/sheathing/insulation/drywall wall construction. Roofing system is a metal deck with built-up flat roofing insulation and a single ply roof membrane. The floor system is a concrete slab on metal decking supported by structural steel beams. Interior Construction and Finishes generally include metal stud/drywall partitions, acoustic and drywall ceilings, resilient and ceramic floor finishes, paint and wall covering wall finishes, hollow metal doors/frames, wood doors, hardware, metal and wood casework, and specialties. Fire Protection includes extension of the existing fire sprinkler system to the addition and complete coverage. Additionally, extension of the existing fire alarm is included with identified coverage. Security and Energy Management systems are extended to the Addition. Plumbing systems generally include sanitary, waste, vent, steam, water, medical gases, and storm water. The medical air and vacuum pumps will be tied into the existing system. Mechanical systems generally include a fully ducted supply and return air system, two AHU located in the Penthouse and support by ground mounted air-cooled chillers. One of the AHU systems will be dedicated to the surgical areas and will include specialized filtering and other requirements for surgical suite occupancy. Electrical systems generally include emergency and normal power, communication systems that include voice/data/security/nurse call systems. The Project power requirements are fed from a 750KVA pad- mounted transformer connected to the campus medium voltage distribution system and the Emergency Power from the existing generator paralleling switchgear system. Lighting generally includes specialized lighting for the ORs, surface, recessed and can-type lighting in various areas. Exterior lighting of the building is provided and existing roadway lighting is relocated as required. 3. Background: This project will replace the existing 2nd floor, Building 113 surgery suite. 4. Performance Period: The contractor shall complete the work required under this SOW in 540 calendar days or less from date of the Notice to Proceed, unless otherwise directed by the Contracting Officer (CO). If the contractor proposes an earlier completion date, and the Government accepts the contractor's proposal, the contractor's proposed completion date shall prevail. Work at the Government site shall not take place on Federal holidays or weekends unless directed by the CO. 5. The North American Industrial Classification System (NAICS) code is 236220, which has a size standard of $33.5M in average annual receipts over the past three years. 6. All interested parties need to provide your companies profile link (vetbiz.gov or ccr.gov), list of previous projects completed of similar magnitude and bonding capacity to Gregg Sutcliffe, Contract Specialist, at gregg.sutcliffe@va.gov (Telephone responses will not be accepted). If you are either a Service Disabled Veteran Owned Small Business, (SDVOSB) or Veteran-Owner Small Business (VOSB), 8(a), Hubzone, or any other category of Small Business that would be interested in bidding on this project. Please respond to this notice by November 1, 2013. 7. Please not that this is not an RFP. 8. Companies responding to this Sources Sought Notification are responsible for all expenses associated with responding to this Notification. (Note: The VA will not pay any costs associated with this effort). 9. The VA is not seeking or accepting unsolicited proposals. Since this Sources Sought Notification is for information and planning purposes, no evaluation letters or results will be issued to respondents.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/OmVAMC636/OmVAMC636/VA26314R0103/listing.html)
 
Document(s)
Attachment
 
File Name: VA263-14-R-0103 VA263-14-R-0103.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1054892&FileName=VA263-14-R-0103-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1054892&FileName=VA263-14-R-0103-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VA Black Hills Health Care System;Fort Meade VA Medical Center;113 Comancee Road;Fort Meade, SD
Zip Code: 57741
 
Record
SN03218599-W 20131020/131018233941-bbfce167136193a6ff3e1dc828165984 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |