DOCUMENT
65 -- Spot check device po 523A30325 - Attachment
- Notice Date
- 10/24/2013
- Notice Type
- Attachment
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- NORTHAMPTON VAMC;421 NORTH MAIN STREET;LEEDS, MA 01053
- ZIP Code
- 01053
- Solicitation Number
- VA24114Q0038
- Response Due
- 10/26/2013
- Archive Date
- 2/2/2014
- Point of Contact
- T.O. OHLSSON, CONTRACT SPECIALIST
- Small Business Set-Aside
- N/A
- Description
- The VA Boston Healthcare System (VABHS) intends to negotiate on a sole source basis pursuant to FAR 6.302-1 -- Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements with MASIMO CORPORATION for the PRONTO 7T SPOT CHECK DEVICE WITH SpHbTr, Sp02,PR PI, that includes Rainbow 4D Spot Check Medium Sensor and Large Sensors with 500 test per sensor capabilities.. This requirement will include the following characteristics: Product Description Hand held hemoglobin spot check meter. Display/Indicators Date Display. SpO2%, pulse rate (PR) beats per minute, SpHb g/dL, PI%, battery level indicator, time, and number of test. Type. 3.7" Resistive touchscreen Physical Characteristics Dimensions. 5.1" x 2.8" x 1" (13 cm x 7.2 cm x 2.5 cm) Weight. 10.5 oz (296.4 g) Visual alarms. Low battery, system failure Electrical Battery power. Rechargeable lithium polymer Capacity. Approximately 2 hours after full charge Number of spot checks on fully charged battery. 140 Battery charging time. 5 hours when powered off 6 hours when powered on Isolation. Medical grade AC/DC adapter AC power. 100-240V, 50-60 Hz, 15VA max. Salient Characteristics Pronto-7 Spot Check Device with SpHb ®, Sp02, PR, Pl. Includes Rainbow 4D Spot Check Medium Sensor (PN9401) and Large Sensor (9402) with 500 Tests per Sensor (PN 3312).The Pronto-7 offers noninvasive and quick spot-check testing of total hemoglobin (SpHb), Sp02, pulse rate, and perfusion index, which may provide the following benefits: Clinician: 1.) Facilitates timely patient assessment 2.) Reduces the need to wait for lab results Staff: 1.) Easy-to-use - Improves efficiency 2.) Decreases risk of accidental needle sticks and exposure to blood-borne pathogens 3.) Requires no lab consumables or waste disposal Patient : 1.) Reduces painful needle sticks and time-consuming blood draws 2.)Enables immediate face-to-face counseling with clinician Pulmonary Function Testing: 1.) to provide current Hemoglobin values so that we may provide an accurate, Diffusion Capacity Results at the time the patient was studied This Notice of Intent is NOT a request for competitive proposals. Parties may identify their interest, accompanied by supporting literature, to the Contracting Officer no later than ENTER DUE DATE AND TIME. Responses should be sent to ENTER EMAIL ADDRESS. Information received will be for the purpose of determining whether or not to conduct a competitive procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NoVAMC/VAMCCO80220/VA24114Q0038/listing.html)
- Document(s)
- Attachment
- File Name: VA241-14-Q-0038 VA241-14-Q-0038.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1061680&FileName=VA241-14-Q-0038-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1061680&FileName=VA241-14-Q-0038-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA241-14-Q-0038 VA241-14-Q-0038.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1061680&FileName=VA241-14-Q-0038-000.docx)
- Record
- SN03221923-W 20131026/131024234254-3a4ae1fe22598fc16a13a9bc3960f4c2 (fbodaily.com)