Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 31, 2013 FBO #4359
SOURCES SOUGHT

Y -- Total Army School System (TASS) at Fort Hunter Liggett, California; Monterey County

Notice Date
10/29/2013
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
USACE District, Louisville, 600 Dr. Martin Luther King, Jr. Place, Room 821, Louisville, KY 40202-2230
 
ZIP Code
40202-2230
 
Solicitation Number
W912QR-14-FHL-TASS-MS
 
Response Due
11/8/2013
 
Archive Date
12/28/2013
 
Point of Contact
Jesse Scharlow, 5023156183
 
E-Mail Address
USACE District, Louisville
(jesse.e.scharlow@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
A market survey is being conducted to determine if there are a reasonable number of interested small business concerns to set this future project aside for them. If your firm is a Small Business, certified HUBZONE, 8A, or Service Disabled Veteran Owned Business, and you are interested in this project, please respond appropriately. Construct (Design/Bid/Build) a Total Army School System (TASS) Training Center (TTC) to the United States Army Corps of Engineers (USACE) General Instruction Building (GIB) standard design that provides 48,649 square feet of schoolhouse training space. The primary facilities to be constructed include a General Instruction Building, Vehicle Maintenance Shop for light maintenance instruction, and an Organizational Storage Building. Buildings will be of permanent construction with reinforced concrete foundations; concrete floor slabs; reinforced concrete or masonry walls; low-slope or sloped roof; heating, ventilation and air conditioning (HVAC); and plumbing, mechanical, security and electrical systems. Supporting facilities include land clearing, paving, fencing, general site improvements and utility connections. Accessibility for the disabled will be provided. Anti-Terrorism/Force Protection (AT/FP) and physical security measures will be incorporated into the design including maximum standoff distances form roads, parking areas and vehicle unloading areas. Sustainability/Energy measures will be provided. Facilities will be designed to a minimum like of 50 years. Energy efficiencies meeting, on average, American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) 189.1 standards through improved building envelope and integrated building systems performance. Contract duration is estimated at 540 days. The estimated cost range is between $10,000,000 and $25,000,000. NAICS is 236220. All interested Small Businesses, certified HUBZONE, 8A, or Service Disabled Veteran Owned Business contractors should respond to this survey by email on 8 November 2013 by 12:00 Eastern Standard Time. Responses should include: (1) Identification and verification of the company's small business status. (2) The level of performance and payment bonding capacity that the company could attain for the proposed project. (3) Descriptions of Experience - Request prime contractor experience on new construction and management of multiple sub-contractors. Provide past experience information on projects with greater than 90% construction complete, or those projects completed within the last five years which are similar to this project in size, and scope. Provide documentation demonstrating Design/Bid/Build construction experience for building projects of similar type buildings involving management of multiple sub-contractors. LEED experience necessary. Additionally, the following capabilities are required for successful contract performance: a. Projects considered similar in scope to this project include: training facilities or education facilities with maintenance bays. b. Projects similar in size will include: new construction projects, greater than 35,000 SF. Based on definitions above, for each project submitted included: a.current percentage of construction complete and the date when it was or will be completed. b.scope of the project c.size of the project d.The portion and percentage of work that was self performed e.Whether the project was design/build or design/bid/build Email responses to Mr. Jesse Scharlow at Jesse.E.Scharlow@usace.army.mil or mail to The US Army Corps of Engineers, Louisville District, 600 Martin Luther King Jr. Place, Room 821, and ATTN: Jesse Scharlow, Louisville, KY 40202-2267. If you have questions please contact Jesse Scharlow at the email address above. This is NOT a Request for Proposal and does not constitute any commitment by the Government. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. All interested sources must respond to future solicitation announcements separately from responses to this market survey.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA27/W912QR-14-FHL-TASS-MS/listing.html)
 
Place of Performance
Address: USACE District, Louisville 600 Dr. Martin Luther King, Jr. Place, Room 821, Louisville KY
Zip Code: 40202-2230
 
Record
SN03224005-W 20131031/131029234159-1cd3a5d90985fa0ee30bc9a139506d20 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.