Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF NOVEMBER 15, 2013 FBO #4374
SOURCES SOUGHT

Y -- Army Reserve Center (ARC) at Fort Story, Virginia

Notice Date
11/13/2013
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
USACE District, Louisville, 600 Dr. Martin Luther King, Jr. Place, Room 821, Louisville, KY 40202-2230
 
ZIP Code
40202-2230
 
Solicitation Number
W912QR-FTSTORY-ARC
 
Response Due
11/25/2013
 
Archive Date
1/12/2014
 
Point of Contact
Jesse Scharlow, 5023156183
 
E-Mail Address
USACE District, Louisville
(jesse.e.scharlow@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
A market survey is being conducted to determine if there are a reasonable number of interested small business concerns to set this future project aside for them. If your firm is a Small Business, certified HUBZONE, 8A, or Service Disabled Veteran Owned Business, and you are interested in this project, please respond appropriately. Construct (Design/Bid/Build) an Army Reserve Center (ARC). Primary facilities include construction of an ARC training building (33,795 SF), Organizational Maintenance Shop (OMS) (8,048 SF), unheated storage building (1,217 SF), and organizational parking (3,730 SF). Buildings will be of permanent construction with reinforced concrete foundations, concrete floor slabs, structural steel frames, masonry veneer walls, standing seam metal roof, Heating, Ventilation, and Air Conditioning (HVAC), plumbing, mechanical systems, security systems, and electrical systems. Supporting facilities include land clearing, paving, fencing, general site improvements, and extension of utilities to serve project. Accessibility for the disabled will be provided. Physical security measures will be incorporated into design including maximum standoff distance from roads, parking areas, and vehicle unloading areas. Berms, heavy landscaping, and bollards will be used to prevent access when standoff distances cannot be maintained. Sustainable Design and Development (SDD) and Energy Policy Act of 2005 (EPAct05) features will be provided. Air Conditioning (Estimated 86 Tons). Contract duration is estimated at 490 days. The estimated cost range is between $10,000,000 and $25,000,000. NAICS is 236220. All interested Small Businesses, certified HUBZONE, 8A, or Service Disabled Veteran Owned Business contractors should respond to this survey by email on 25 November 2013 by 12:00 Eastern Standard Time. Responses should include: (1) Identification and verification of the company's small business status. (2) The level of performance and payment bonding capacity that the company could attain for the proposed project. (3) Descriptions of Experience - Request prime contractor experience on new construction and management of multiple sub-contractors. Provide past experience information on projects with greater than 90% construction complete, or those projects completed within the last five years which are similar to this project in size, and scope. Provide documentation demonstrating Design/Bid/Build construction experience for building projects of similar type buildings involving management of multiple sub-contractors. LEED experience necessary. Additionally, the following capabilities are required for successful contract performance: a. Projects considered similar in scope to this project include: Army Reserve Centers, Armed Forces Training Centers, police stations, office complexes, laboratories, vehicle maintenance shops, training facilities, or education facilities. b. Projects similar in size will include: new construction projects, greater than 35,000 SF. Based on definitions above, for each project submitted included: a.current percentage of construction complete and the date when it was or will be completed. b. dollar value of the project c.scope of the project d.size of the project e.The portion and percentage of work that was self performed f.Whether the project was design/build or design/bid/build Email responses to Mr. Jesse Scharlow at Jesse.E.Scharlow@usace.army.mil or mail to The US Army Corps of Engineers, Louisville District, 600 Martin Luther King Jr. Place, Room 821, and ATTN: Jesse Scharlow, Louisville, KY 40202-2267. If you have questions please contact Jesse Scharlow at the email address above. This is NOT a Request for Proposal and does not constitute any commitment by the Government. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. All interested sources must respond to future solicitation announcements separately from responses to this market survey.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA27/W912QR-FTSTORY-ARC/listing.html)
 
Place of Performance
Address: USACE District, Louisville 600 Dr. Martin Luther King, Jr. Place, Room 821, Louisville KY
Zip Code: 40202-2230
 
Record
SN03233268-W 20131115/131114000229-4a558ba8aae23a825c1c12eb0a6f9250 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers