SOURCES SOUGHT
Z -- Renovate Buildings 3709 and 3710 located at Corry Station, NAS Pensacola, FL
- Notice Date
- 1/16/2014
- Notice Type
- Sources Sought
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of the Navy, Naval Facilities Engineering Command, NAVFAC Southeast, Bld 903, P.O. Box 30 (Bldg 903), Jacksonville, Florida, 32212-0030, United States
- ZIP Code
- 32212-0030
- Solicitation Number
- N69450-14-R-1156
- Archive Date
- 3/4/2014
- Point of Contact
- Barbara A Czinder, Phone: (904) 542-6834
- E-Mail Address
-
barbara.czinder@navy.mil
(barbara.czinder@navy.mil)
- Small Business Set-Aside
- N/A
- Description
- THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS OR DRAWINGS AVAILABLE AT THIS TIME. ********************* The Naval Facilities Engineering Command Southeast (NAVFAC SE) is seeking qualified and interested parties in any of the following categories: U.S. Small Business Administration (SBA) certified 8(a), HUBZone Small Business (HUBZone), Service Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business, Women Owned Small Business (WOSB) and/or Small Business (SB) sources with current relevant qualifications, experience, personnel, and capability to perform. The solicitation number for this Notice is N69450-14-R-1156 entitled Renovate Buildings 3709 and 3710 located at Corry Station, NAS Pensacola, FL. The anticipated award date is approximately 30 September 2014. ********************************** The Naval Facilities Engineering Command Southeast (NAVFAC SE) located in Jacksonville, Florida will be the procuring agency for this project and intends to ultimately award a Firm Fixed Price (FFP) Design Bid Build construction contract in the dollar between of $10Million and $20 Million. The NAICS code for this solicitation is for 236220, General Construction. The Small Business Size Standard is $33,500,000. ************************* There is no bid package or solicitation. No telephone calls will be accepted requesting a bid package or solicitation. In order to protect the procurement integrity of any future procurement, if any, that may arise from this announcement, information regarding the technical point of contact will not be given and no appointments for presentations will be made. Source sought number will not be the same solicitation number. ******************************* The Government will use responses to this SOURCES SOUGHT Notice to make appropriate acquisition decisions. **************************************** Project Description: Renovate Buildings 3709 (20,306 SF) and 3710 (20,824 SF) to provide 196 berths. Repairs to the building will correct code violations. Each building will have one mechanical room and one electrical room. The buildings will have a laundry and study on each floor, with television/game rooms on the first floor. Buildings 3709 and 3710 will both have 49 2+0 rooms with 98 berths. Renovations will include but are not limited to the following work: gut buildings, replace structural steel as required, replace interior sheetrock on walls and ceilings, replace all electrical wiring and equipment, replace all plumbing, including water supply, sewer, and fixtures, provide voice, data and CATV connections, install fire suppression and detection systems, renovate to ATFP standards, including impact rated insulating glass units, replace floor coverings, replace all doors, replace roof with a standing seam metal hip roof, replace existing HVAC system with PTAC units in each room; provide make-up air with central air handlers utilizing chilled/hot water from B3706, and install new walkways and handrails on the rear and sides of building. ******************** The Government invites contractors with the capabilities necessary to meet or exceed the stated requirements to submit Capability Statements consisting of appropriate documentation, literature, brochures, and references anticipated to be two to six pages, following the set format below: ************************************* 1) Provide company information to include name, address, phone number, email address and DUNS number. ********************** 2 ) Business size and socio-economic program (Small Business, HUBZone, 8(a), SDVOSB, etc); **************** 3) Bonding Capacity: Provide surety's name, telephone number and point of contact, your maximum bonding capacity per project. ******************** In addition to the general information above, interested offerors must provide the following specific information: ****************** 4) Provide a minimum of two projects performed as a Design-Bid-Build general renovation projects (office, dormitories or hotels) for which you were Prime contractor that were completed within the last seven years; projects should be of similar size, scope and complexity as the work indicated above. Indicate project specifics (brief description of the project) and provide references with names, email addresses and phone numbers as well as compeletion date and contract value. **************************** 5) Projects submitted should demonstrate general renovation projects (office, dormitories or hotels) with a value of approximately $5 million or greater. ******************* The Capabilities Statement for this Sources Sought Notice is not expected to be a proposal, but rather short statements regarding the company's ability to demonstrate existing-or-developed expertise and experience in relation to the areas specified herein. Any commercial brochures or currently existing marketing material may also be submitted with the Capabilities statement. Submission of Capabilities statement is not a prerequisite to any potential future offerings, but participation will assist the Government in tailoring requirements to be consistent with industry capabilities. After completing its analysis, the Government will determine whether to limit competition among a small business category set-aside or to proceed with issuing an unrestricted solicitation, inviting full and open competition. ******************** Your response to this sources sought announcement must be received by 3:00 pm ET on 17 February 2014 and may be received electronically. Please ensure email size is limited to less than 5 MB and email your response to Barbara.Czinder@navy.mil.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/04ac9196e134f98910134f4d81af8ecc)
- Place of Performance
- Address: Corry Station, Naval Air Station Pensacola, FL, Pensacola, Florida, United States
- Record
- SN03269373-W 20140118/140116234508-04ac9196e134f98910134f4d81af8ecc (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)