DOCUMENT
Y -- Design/Build and Design/Bid/Build Construction Services for PNY B633 Power Switching Equipment Installation, Philadelphia, Pennsylvania - Attachment
- Notice Date
- 2/20/2014
- Notice Type
- Attachment
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- N40085 NAVFAC Mid-Atlantic Naval Facilities Engineering Command, Mid-Atlantic Code AQ, 9742 Maryland Avenue Norfolk, VA
- Solicitation Number
- N4008514R5212
- Response Due
- 3/21/2014
- Archive Date
- 3/31/2015
- Point of Contact
- Lynn Lovejoy
- Small Business Set-Aside
- N/A
- Description
- The primary focus of the project includes demolition, earthwork, pile supported concrete foundations, structural steel platforms, ductbanks, utilities, electrical power, controls systems and incidental related work. The objective of the project is to further expand on the existing MILCON P-205 Full Scale Electric Drive Test Facility infrastructure in order to perform full scale propulsion system testing. This project is also a follow-on effort associated with MILCON P-536 Energy Recirculation System and Electric Machinery Equipment Installation (EMEI) projects. The new system will support a loading configuration that will allow energy recovery during load emulation. To support the power recirculation loading configuration the re-arrangement of the existing electrical switching equipment configuration and connections is required. The project will connect to the MILCON P-205 infrastructure in Building 633 and Building 77H. Specifically the project will include connection of a government furnished Gas Turbine Generator (GTG) output to existing infrastructure; modifications and additions to existing switchgear; installation of government furnished transformers; instrumentation and controls; and related civil and structural improvements.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62470HR/N4008514R5212/listing.html)
- Document(s)
- Attachment
- File Name: N4008514R5212_Sources_Sought_Notice_Power_Switching_Bldg_633.pdf (https://www.neco.navy.mil/synopsis_file/N4008514R5212_Sources_Sought_Notice_Power_Switching_Bldg_633.pdf)
- Link: https://www.neco.navy.mil/synopsis_file/N4008514R5212_Sources_Sought_Notice_Power_Switching_Bldg_633.pdf
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: N4008514R5212_Sources_Sought_Notice_Power_Switching_Bldg_633.pdf (https://www.neco.navy.mil/synopsis_file/N4008514R5212_Sources_Sought_Notice_Power_Switching_Bldg_633.pdf)
- Place of Performance
- Address: 1413 Langley Avenue
- Zip Code: BUILD 633, PHILADELPHIA NAVAL YARD (PNY), PHILADELPHIA, PA
- Zip Code: BUILD 633, PHILADELPHIA NAVAL YARD (PNY), PHILADELPHIA, PA
- Record
- SN03292192-W 20140222/140220234434-662464f88be325d654624adff4488352 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |