Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 26, 2014 FBO #4477
SOURCES SOUGHT

66 -- GOW-MAC Series 400 Basic Isothermal Gas Chromatograph

Notice Date
2/24/2014
 
Notice Type
Sources Sought
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
MICC - West Point, Directorate of Contracting, ATTN: SFCA-NR-WP, 681 Hardee Place, West Point, NY 10996-1514
 
ZIP Code
10996-1514
 
Solicitation Number
CHROMATOGRAPHS
 
Response Due
2/27/2014
 
Archive Date
4/25/2014
 
Point of Contact
Vivian Malta, 845-938-8637
 
E-Mail Address
MICC - West Point
(vivian.malta@usma.edu)
 
Small Business Set-Aside
N/A
 
Description
The U.S. Military Academy at West Point intends to purchase two (2) GOW-MAC Series 400 Basic Isothermal Gas Chromatographs with Thermal Conductivity Detector. We are seeking vendors who offer this equipment OR equal equipment by different manufacturer. If you can provide this, please contact the listed Contract Specialist via email. THIS IS NOT A SOLICITATION AND WE ARE NOT ACCEPTING OFFERS AT THIS TIME. SPECIFICATIONS: At a minimum, each of the following elements are required as part of the specification for this equipment. Gas chromatograph with Thermal Conductivity Detector (TCD) Contractor will supply all hardware required for installation and verification of operation. Ruggedized for student use. Column Oven o Temperature Control:.solid state time proportioning, RTD sensors, direct reading o Temperature Range: Ambient to 300 'C o Column Oven Temperature Protection Circuit: shuts the column off if the temperature rises to 30 over setpoint. o Accommodates two l/4 quote mark OD x 12' columns or correspondingly longer lengths of 1/8 quote mark OD. o Dual Column. o Direct temperature setpoints. Detector Oven o Temperature Control:.solid state time proportioning, RTD sensors, direct reading o Temperature Range: Ambient to 300 'C o Temperature Readout: 3 digit LED digital meter Gas Flow o Dual Column o Two metering valves for independent flow control to each column Detector Power Supply o Constant Current: 300mA max. o Noise and Ripple: less than 5 V RMS TCD Bridge Control o Continuous current adjust to 300mA o Bridge zero adjust o Attenuator for bridge output, 12 positions to 1024, plus infinity ( ) Detector o Thermal Conductivity (TCD) o Response Time: 0.5sec o Four detector elements, rhenium-tungsten filaments o Noise: 10 V max o Drift: less than 40 V/hr max o Carrier Gas: He, N2 or Ar o Upper Current Limit: 300mA (He) 100mA (N2) Injection Ports o Two; on-column o Low volume o 9mm septa o Temperature Control:.solid state time proportioning, RTD sensors, direct reading o Temperature Range: Ambient to 300 'C o Temperature Readout: 3 digit LED digital meter Power Requirements o 110-130VAC, 60Hz, 900W o Circuit Breaker: 10A Physical Dimensions o 12 quote mark W x 11 quote mark D x 16.5 quote mark H o Weight 27lbs
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/2a0d159906821335a3873b663377d203)
 
Place of Performance
Address: MICC - West Point Directorate of Contracting, ATTN: SFCA-NR-WP, 681 Hardee Place West Point NY
Zip Code: 10996-1514
 
Record
SN03295407-W 20140226/140224234831-2a0d159906821335a3873b663377d203 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.