MODIFICATION
Z -- Tank Spill Protection and Monitoring , Nashville, TN
- Notice Date
- 2/26/2014
- Notice Type
- Modification/Amendment
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- General Services Administration, Public Buildings Service (PBS), Property Management Division (4PM)*, 401 West Peachtree Street, Suite 2416, Atlanta, Georgia, 30308
- ZIP Code
- 30308
- Solicitation Number
- GS-04P-14-EXC-0045
- Archive Date
- 4/26/2014
- Point of Contact
- Dee O Henderson, Phone: 404-331-9792
- E-Mail Address
-
dee.henderson@gsa.gov
(dee.henderson@gsa.gov)
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- Contractor shall furnish all labor, equipment, materials and supervision for Tank spill Protection and Monitoring. Existing tank is 12,000 gallons, steel single-wall located in vault below rear parking adjacent to building. This project has a 60 calendar day performance period following Notice To Proceed. The Contractor shall provide and install a fuel leak sensor (Veeder Root TSL 330c or other like equipped) System must be able to have remote monitoring and send alerts to GSA personnel. System must also have an on-site printer. All connections and electrical work must be performed by contractor shall be to NEC standards. Contractor shall repair the clean fuel vault. Which includes but not limited to hydraulic crack repair, 24" CMU construction and prepping surfaces for epoxy paint. Demo opening for access through vault wall from basement mechancial space. Provide and install 2 ea metal lockable doors for the vault 24" above the deck. Contractor shall provide and use petroleum resistant epoxy paint for the flooring and 24" min on the interior of the vault. Contractor shall provide Spill Prevention, Control, and Countermeasure plan. This plan shall be developed by and certified by a registered Professional Engineer (PE). By certifying the SPCC Plan, the Professional Engineer, having examined the facility, attests that: 1. (s)he is familiar with the requirements of Part 112; 2. the engineer or their agent has visited and examined the facility; 3 the Plan has been prepared in accordance with good engineering practices, including consideration of applicable industry sstandards, and with the requirements of Part 112; 4. procedures for required inspections and testing have been established; and 5. the Plan is adequate for the facility. The quality of materials and finishes shall be equal to or exeed the existing. A 1 year warranty shall be provided against defect in material and wormanship. All work must be conducted between after hours including weekends unless noted otherwise. Contractor shall be responsible for the removal of all trash and debris generated during this project on a daily basis. Liquidated Damages are $15.42 per day. Construction Magnitude is $25,000 to $100.000.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/4PMAtlanta/GS-04P-14-EXC-0045/listing.html)
- Place of Performance
- Address: Nashville Courthouse TN0052AA, 801 Broadway, Nashville, TN 37203-3816, Nashville, Tennessee, 37203, United States