Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 28, 2014 FBO #4479
MODIFICATION

Z -- Tank Spill Protection and Monitoring , Nashville, TN

Notice Date
2/26/2014
 
Notice Type
Modification/Amendment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
General Services Administration, Public Buildings Service (PBS), Property Management Division (4PM)*, 401 West Peachtree Street, Suite 2416, Atlanta, Georgia, 30308
 
ZIP Code
30308
 
Solicitation Number
GS-04P-14-EXC-0045
 
Archive Date
4/26/2014
 
Point of Contact
Dee O Henderson, Phone: 404-331-9792
 
E-Mail Address
dee.henderson@gsa.gov
(dee.henderson@gsa.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Contractor shall furnish all labor, equipment, materials and supervision for Tank spill Protection and Monitoring. Existing tank is 12,000 gallons, steel single-wall located in vault below rear parking adjacent to building. This project has a 60 calendar day performance period following Notice To Proceed. The Contractor shall provide and install a fuel leak sensor (Veeder Root TSL 330c or other like equipped) System must be able to have remote monitoring and send alerts to GSA personnel. System must also have an on-site printer. All connections and electrical work must be performed by contractor shall be to NEC standards. Contractor shall repair the clean fuel vault. Which includes but not limited to hydraulic crack repair, 24" CMU construction and prepping surfaces for epoxy paint. Demo opening for access through vault wall from basement mechancial space. Provide and install 2 ea metal lockable doors for the vault 24" above the deck. Contractor shall provide and use petroleum resistant epoxy paint for the flooring and 24" min on the interior of the vault. Contractor shall provide Spill Prevention, Control, and Countermeasure plan. This plan shall be developed by and certified by a registered Professional Engineer (PE). By certifying the SPCC Plan, the Professional Engineer, having examined the facility, attests that: 1. (s)he is familiar with the requirements of Part 112; 2. the engineer or their agent has visited and examined the facility; 3 the Plan has been prepared in accordance with good engineering practices, including consideration of applicable industry sstandards, and with the requirements of Part 112; 4. procedures for required inspections and testing have been established; and 5. the Plan is adequate for the facility. The quality of materials and finishes shall be equal to or exeed the existing. A 1 year warranty shall be provided against defect in material and wormanship. All work must be conducted between after hours including weekends unless noted otherwise. Contractor shall be responsible for the removal of all trash and debris generated during this project on a daily basis. Liquidated Damages are $15.42 per day. Construction Magnitude is $25,000 to $100.000.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/4PMAtlanta/GS-04P-14-EXC-0045/listing.html)
 
Place of Performance
Address: Nashville Courthouse TN0052AA, 801 Broadway, Nashville, TN 37203-3816, Nashville, Tennessee, 37203, United States
Zip Code: 37203
 
Record
SN03297783-W 20140228/140226234954-6fbf6c33343611f5dbaea9fee97233fc (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.