Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 13, 2014 FBO #4492
SOLICITATION NOTICE

61 -- Electrical Work, High Voltage

Notice Date
3/11/2014
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Labor, Employment Training Administration, Edison Job Corps Center, 500 Plainfield Avenue, Edison, New Jersey, 08817
 
ZIP Code
08817
 
Solicitation Number
14Q0002
 
Point of Contact
Dave Franklin, Phone: 732-393-3509
 
E-Mail Address
franklin.dave@jobcorps.gov
(franklin.dave@jobcorps.gov)
 
Small Business Set-Aside
N/A
 
Description
"THIS IS A SUBCONTRACTING OPPORTUNITY" Prevailing wage rates are required. Edison Job Corps/ResCare, Inc., contracting for the U.S. Department of Labor, for the operation of Edison Job Corps Center, is currently soliciting written proposals for the discribed scope of work written below for the Edison Job Corps Center. Job Corps, a federal program administered by U.S. Department of Labor provides Academic and Vocational Training to economically disadvantaged youth between the ages of 16 to 24. Scope of Work (SOW) 1. Utilization of tape shielded cable at the service entrance to the Y-Y configuration oil type pad-mounted transformer serving Female Dormitory Building 15 (installed 2003) results in inadequate grounding and bonding. Inadequate grounding leads to unsafe condition for the center personnel maintaining this transformer and for the students due to unstable and fluctuating voltage in the building. 2. Missing neutral was provided from the riser pole to the manhole during the emergency site visit regarding power outage in Dormitory Building 1. However continuity of the neutral as well as grounding and bonding at the riser pole, manhole and both transformers serving Buildings 1 and 15 is in question. Neutral continuity at both transformers serving buildings 1 and 15 needs thorough verification by the certified medium voltage electrical engineer. Missing neutral, uncontinuous neutral, improper grounding and bonding lead to unsafe condition. 3. Three disconnect switches mounted at the back of the pad-mounted transformer serving Gymnasium Building 4 obstruct minimum required working space at the transformer location and increase time needed to replace this transformer in case of a failure. These disconnects need to be remounted on the independent support structure. Three disconnects consists of the 600A and 400A disconnects serving Gymnasium Building 4 and one 200A disconnect serving Cabana Building 12. 4. Service entrance to the pad-mounted transformer at Gymnasium Building 4 is inadequate due to the multiple improperly supported taps, poor connections, and inadequate installed PVC conduit. Improper connections and taps could result in overheating and power outages. 5. The middle voltage secondary distribution system belongs to the center and center maintenance personnel involved in the electrical equipment maintenance (four persons) should receive at least 8 hour training course covering requirements of NFPA 70E. NFPA 70E "Electrical Safety in the workplace" was adopted in state of New Jersey at May 2012. The NFPA 70E requirements cover standards and practices to be followed to protect workplace from arc flash safety hazard. Lack of training could lead to unsafe workplace condition. Please provide a detailed cost breakdown. Labor: $_______________ Parts/Equipment: __________________ Term: _________________ Performance Period: _________________
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOL/ETA/ejcc/14Q0002/listing.html)
 
Place of Performance
Address: Edison Job Corps Center, 500 Plainfield Avenue, Edison, New Jersey, 08817, United States
Zip Code: 08817
 
Record
SN03307886-W 20140313/140311235231-f8b538d3ca8a9c5b0d6dde8d57f6b392 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.