Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 28, 2014 FBO #4507
SOURCES SOUGHT

Y -- FY14 St. Marys River, MI Protective Relays and Station Service Upgrade - Sources Sought Information Request Form

Notice Date
3/26/2014
 
Notice Type
Sources Sought
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Detroit, 477 Michigan Avenue, Detroit, Michigan, 48226, United States
 
ZIP Code
48226
 
Solicitation Number
W911XK-14-R-0018
 
Archive Date
4/25/2014
 
Point of Contact
Carlette L. Williams, Phone: 3132262683, Sandra Marie Kenzie,
 
E-Mail Address
Carlette.l.Williams@usace.army.mil, sandra.m.kenzie@usace.army.mil
(Carlette.l.Williams@usace.army.mil, sandra.m.kenzie@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Sources Sought Information Request Form This is a SOURCES SOUGHT notice. The U.S. Army Corps of Engineers Detroit District is seeking firms that have the capability of the removal and replacement of protective relays and switchgear/motor control assemblies within a 21.5 megawatt hydropower plant. The protective relays monitor the current, voltage, frequency, and other types of electric power measurement for the purpose of triggering circuit breakers to open in the event of an abnormal condition. The switchgear/motor control assemblies provide centralized control, protection, and distribution of 460VAC 3Φ and 125V DC electrical power to auxiliary plant equipment and circuits. The project will also include related incidental work such as removal and replacement of ancillary equipment, cabling, supports, etc. The contract will have a 12 month completion requirement. The contract is expected to be awarded in September 2014. The estimated cost of construction is between $1,000,000 and $5,000,000. The North American Industrial Classification System (NAICS) code is 238210, which has a size standard of $14 Million in average annual receipts. This project requires knowledge of electrical and hydropower. The Government will evaluate the potential offerors based on price, past performance, experience with similar work, and proposed schedule. This is NOT a request for proposal. This announcement is for planning purposes only. Qualified companies are encouraged to respond. The response to this notice shall be in summary format and shall not exceed eight (8) pages, including the attached response form. In order to determine the extent of industry interest and experience in the project, interested contractors shall present the following information: 1. A completed Sources Sought Information Request Form located in this "Sources Sought" notice on www.FBO.gov. 2. If applicable, identification and verification of the company as a Small Business, HubZone, 8(a), Service Disabled Veteran Owned Business, and/or Woman Owned Small Business, subject to verification by the Small Business Administration. 3. A letter from the firm's bonding company verifying that the firm can be bonded up to the amount of this project (construction bonding level per contract and aggregate construction bonding level, both expressed in dollars). 4. Past Experience - provide descriptions of three projects substantially complete or completed within the last five years which are similar to this project in size, scope, and dollar value. 5. A statement identifying what portion of the work would be self performed, and how it would be accomplished. Qualified companies, regardless of their size or socio-economic status, are encouraged to respond. No basis for claim against the Government shall arise as a result of a response to this sources sought or Government use of any information provided. The Government will not pay for information or comments provided and will not recognize any costs associated with submission of comments. All firms that are interested in responding are invited to submit their information via email only to the Contracting Division at LRE-Quotes@usace.army.mil and Carlette.L.Williams@usace.army.mil. Responses must be provided in either Microsoft Word or Adobe Acrobat PDF format. Please submit responses no later than the time stated in this notice on www.fbo.gov. Please reference "SOURCES SOUGHT: W911XK-14-R-0018 FY14 St. Marys River, MI - Protective Relays and Station Service Upgrade " in the subject line. Respondents will not be contacted regarding their submission or information gathered as a result of this Sources Sought notice. The formal solicitation will be issued at a later date by a separate announcement.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA35/W911XK-14-R-0018/listing.html)
 
Place of Performance
Address: St. Marys, Louisiana, United States
 
Record
SN03321118-W 20140328/140326235231-a903e4927106fe2b4a3886d186d63007 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.