Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 15, 2014 FBO #4555
DOCUMENT

J -- Remove Install Dental Vacuum and Replace Piping for Veterans Affairs Palo Alto Health Care System at Livermore VA Medical Center A short term project. - Attachment

Notice Date
5/13/2014
 
Notice Type
Attachment
 
NAICS
561990 — All Other Support Services
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO 21);VA Northern California HealthCare System;5342 Dudley Blvd. Bldg. 209;McClellan CA 95652-1012
 
ZIP Code
95652-1012
 
Solicitation Number
VA26114R0538
 
Response Due
5/21/2014
 
Archive Date
8/28/2014
 
Point of Contact
Leala Jew
 
E-Mail Address
3-4516<br
 
Small Business Set-Aside
Total Small Business
 
Description
This is a Sources Sought Notice - Constitutes Market Research This Sources Source Notice is to seek out Interested Vendors identified as Service Disabled Veteran Owned (SDVOSB), Veteran Owned Small Businesses (VOSB), all other Small Businesses and any Large Businesses interested in bidding on this requirement. If interested in bidding, vendors should notify the Contracting Officer by emailing Leala.Jew@va.gov by the due date indicated on the Sources Sought notice. Synopsis of Work: The Veterans Affairs Palo Alto Health Care System (VAPAHCS) at 4951 Arroyo Road, Livermore, California 94550, Building 62, a dental clinic operates four chairs, six days a week. The current dental vacuum system identified as Gardner Denver was installed in 1973 utilizing a non-positive-displacement pump multi-stage centrifugal system. The current vacuum system has a 480 volt, 3-phase motor manually controlled from the dental clinic via a push button control. The main vacuum lines are 2-inch copper tubes running from the basement room number 9 to room number 247, 248 and 251 on the second floor. Description of the Required Work: The branch lines have recently been upgraded from ¾ inch tube to 1 ½ inch tube. The jet flow, 14 gallon separation tank is damaged and is held together with "duct tape plumbed with ABS" and without an amalgam separator. The ABS exhaust tubing from the vacuum producer is not within VA specifications and has the potential to fail or harm maintenance staff. The VA dental clinic has complained that the vacuum system does not provide adequate suction during dental clinic procedures. The current suction is between 2.5-3 SCFM (standard cubic feet per minute) which does not satisfy the VA specification of a minimum suction of 7 SCFM at each high volume oral evacuation (HVE). Four Major Tasks 1. The Contractor shall procure and install VPD10D2- ECO Dry-VAC System or brand name or equal and SolmeteX HG5 Amalgam separator per manufacturer's installation instructions and VA Specifications. 2. The Contractor shall remove and replace with existing dental vacuum system, ABS plumbing and components without interruption of service. 3. The Contractor shall purchase the necessary materials and components to replace the ABS plumbing with copper tubing and install the trap seal primer. 4. The Contractor shall modify and relocate the existing sump pit guardrail and access ladder. The Contractor shall paint the guardrail to match existing colors. The proposed NAICS code is 561990 and small business size is $10.0 million. The VA intends to award a Firm-Fixed Price contract. Period of Performance will begin immediately after award of contract. No formal solicitation document exists at this time. Responses to this sources sought notice should be emailed to Leala.Jew@va.gov no later than 4 PM, Pacific Standard Time, on the due date indicated on the notice. Include the following information: POC Name and address of company, phone numbers, DUNS number, and email address. Respond directly to Leala.Jew@va.gov DO NOT SEND PROPOSALS at this time. Email any questions directly to Leala.Jew@va.gov DISCLAIMER This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this notice that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANCHCS/VANCHCS/VA26114R0538/listing.html)
 
Document(s)
Attachment
 
File Name: VA261-14-R-0538 VA261-14-R-0538 SOURCES SOUGHT NOTICE.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1361884&FileName=VA261-14-R-0538-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=1361884&FileName=VA261-14-R-0538-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN03364761-W 20140515/140514021743-779237564215f3852e5e0760f3a39517 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |